Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung Sears, modell 233.52059

Hersteller: Sears
Dateigröße: 454.26 kb
Dateiname:
Unterrichtssprache:enes
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


• Based on _Kitchen Fir_safetyTips _ published by NFPA. 2. To reduce the risk of Rre or electrical shock,this range hood should not be used with an additional speed control device. 3. To reduce the risk of shock, disconnect power before servicing. 4. To reduce the risk of fire and to properly exhaust air, be sure to duct air outside. PLAN THE INSTALLATION Recommended mounting height is 18 _to 24 _from the bottom of the range hood to the top of the cooking surface. The hood should be mounted to the bottom of a standard wall cabinet. If the hood must be mounted directly to a wall, secure the hood to wall studs. All wiring must comply with local codes and the unit must be properly grounded.The hood is connected to a 110-120vAC lighting circuit (15 amp) in the circuit breaker or fuse box. This range hood is "Convertible'-it may be installed as a ducted or as a non-ducted unit. IFTHE RANGE HOOD ISTO BE NON-DUCTF, D: • Purchase nonMucted (duct-free) charcoal filter Model BPQTE IFTHE RANGE HOOD ISTO BE DUCTED: • Ductwork can be installed vertically or horizontally. • Duct runs should Be as short as possible. • Avoid the use of elbows. • Use duct tape at all joints. • Do not use duct smaller than the discharge on the hood. • For 7" round ductwork installation, use 7 _round damper, Model BP87 (purchased separately). HORIZONTAL DISCHARGE THROUGH WALL CUTOUT DIMENSIONS / WALL KITCHEN CABINET SUPPUED DUCT DD TRANSmON WALL CAP 7." RANGEHOOD / 5." __ w_& In[G_ I VERTICAL DISCHARGE ROOF CAP USING 3V4" x 10" DUCT CUTOUT DIMENSIONS TOP VIEW T EAVE CAP 9" 1 3Y4"X 10" DUCT _'J/I--_"="I_L L,. t-11/2" SUPPLIED DUCT WALL CAP BACK VIEW a!'{] -ELEC. K.O._ ",.I r--3/_" _ T TRANSITION WALL RANGE HOOD VERTICAL DISCHARGE USING 7" ROUND DUCT ROOFCAP CUTOUT DIMENSIONS ADJUSTABLE ELBOW CL _""ROOF TOP VIEW 17 = TDL_ J 9" 7"ROUND DUCT REMOVE BOTH 3." x 10" AND7" HALF ROUND _.J/'l-_,,,:: ,,.. Lll/2 . 7"ROUND DAMPER KNOCKOUTS FOR 7" DUCT _UPPLIED 7" ROUND BACK VIEW X_, o-I IF_ RANGE HOOD DUCT TRANSITION _GtrBLE 3 PREPARATION 1. Use the dimensional drawings (Refer to FIGURES 1 -3) to lay out the range hood's mounting holes, vin'ing access and ductwork by marking the cabinet bottom and drywall where applicable. 2. Make cutouts for wiring and ductwork. 3. If the hood is to be ducted,install the ductwork so that is flush to the range hood's mounting surface. Refer to FIGURE 1 if the range hood is to be installed with a horizontal discharge. Refer to FIGURE 2 and FIGURE 3 if the range hood is to be installed with a vertical discharge. 4. Run two-conductor wire (with ground) from a power source to the hood location.B(mg approximately 12"of wiring through wiring hole in cabinet. 5. DriU four 3/32" diameter pilot holes at points where mounting holes are marked in cabinet bottom. 6. Insert four (4) mounting screws, leaving approximately ." of thread exposed. 7. Remove and retain the mounting screws securing the 3."x 10" and 7 _ duct transitions to the hood. Install the appropriate duct tra...

Dieses Handbuch ist für folgende Modelle:
Ventilatoren - 233.52053 (454.26 kb)
Ventilatoren - 233.52159 (454.26 kb)
Ventilatoren - 233.52157 (454.26 kb)
Ventilatoren - 233.52153 (454.26 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien