Login:
Stimmen - 3, Durchschnittliche Bewertung: 4 ( )

Anleitung Waterford Precision Cycles, modell Chimney Hood

Hersteller: Waterford Precision Cycles
Dateigröße: 82.04 kb
Dateiname: 689b7491-b993-444b-abb0-8b73596c2d80.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


WARNING! Do not connect the appliance to the mains until the installation is fully complete. ELECTRICAL CONNECTION The mains power supply must correspond to the rating indicated on the plate situated inside the hood. A double-pole switch must be fitted in accordance with the relevant standards. Attention: Replacing the supply cable must be carried out by a Qualified Electrician or an Authorised Service Agent. The appliance is only intended for use by competent persons. Children should be supervised to ensure that they do not play with the appliance. Never use the hood without being securely fixed using the brackets supplied. The hood must never be used as a support surface unless specifically indicated. If the appliance is fitted in a room with one or more appliances that require an air supply, an adequate air supply must be provided so that these appliances can function simultaneously at maximum operation. If venting outside, the vent pipe must run direct from the hood to an external wall. The use of exposed flames beneath the hood is detrimental to the filters and may cause a fire risk, and must be avoided at all times. Waterford Stanley recommend a distance of 650-750mm between the cooking appliance and the hood, see Installation Section provided in this manual. The hood must be regularly cleaned on both the inside and outside AT LEAST ONCE A MONTH. MAINTENANCE ATTENTION! Before performing any maintenance, isolate the hood from the electrical supply. Grease Filter This must be cleaned once a month using a non aggressive detergent, either by hand or in the dishwasher, which must be set to a low temperature and a short cycle. When washed in a dishwasher, the grease filter may discolour slightly, but this does not affect its filtering capacity. REPLACING LAMPS Warning! Ensure light bulbs are cool before touching. Ensure all lamps are correctly fitted to the hood at all times to avoid a possible safety hazard. This appliance is marked according to the European Directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE). By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. The symbol on the product, or on the documents accompanying the product, indicates that this appliance may not be treated as household waste. Instead it should be taken to the appropriate collection point for the recycling of electrical and electronic equipment. Disposal must be carried out in accordance with local environmental regulations for waste disposal. For more detailed information about treatment, recovery and recycling of this product, please contact your local council, your household waste disposal service or the shop where you purchased the product. 1 GENERAL GUIDELINES INSTRUCTIONS FOR ASSEMBLY Before installing and /or using the cooker hood, please read these instructions carefully. Before installing the cooker hood make sure the voltage (V), frequency (Hz) indicated on the serial number plate and specifications on the rating plate on the inside of the cooker hood correspond to the voltage and frequency of the mains supply. INSTALLATION The cooker hood must not be installed and connected to flues where other appliances are installed and which run off other energy supplies other than electricity (water heaters - boilers - cookers, range/gas etc). The extraction hood requires a 125mm extraction pipe connected directly to the outside with an opening of a minimum cross section of 150cm2. The hood must be installed with a distance of 650750mm between the cooker top/hob and the extraction hood. The cooker hood must not be installed above cookers with eye-level grills. ELECTRICAL CONNECTION This cooker hood is designed for permanent fixture. Connect to mains supply. Check voltage and frequency given on the rating plate located on the inside of the hood. Connect the mains cable to a power socket or to a double pole switch with a contact gap of at least 3mm. The mains cable (type H05VV- F 2x 0.75 mm2) is connected to terminals marked with the letters L (power line) and N (neutral) mounted on the hood and is secured in position by a cable gland. The mains cable must be connected to a suitable and easily accessible fixed power point. As the electrical installation must comply with the laws and regulations in force only a qualified and authorised electrician must install the hood including connecting it to a double pole switch with a contact gap of at least 3mm. Connect the mains cable if provided with a plug to a power socket. The user must have access to the power socket to be able to connect and disconnect the plug once the hood is mounted and fixed or the mains cable can be plugged into a socket with a double pole switch with a contact gap of at least 3mm. The manufacturer will not be responsible if the governing health and safety laws are not observed w...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien