7. For Direct Wire Installations: ¦ Install a UL listed or CSA approved strain relief. A A. UL listed or CSA approved strain relief ¦ Pull about 12" (30 cm) of wire through wall or cabinet and into opening. For Power Supply Installations: ¦ Follow instructions included with power supply cord kit marked for range hoods. NOTE: If the wall cap is directly behind the vent connector/ damper, the damper in the connector and wall cap must not interfere with each other. Remove the vent connector damper if it interferes. 8. Using 2 people, lift range hood into final position, feeding electrical wire through wiring opening. Position the range hood so that the large end of the keyhole slots are over the screws. Then push the hood toward the wall so that the screws are in the neck of the slots. Tighten mounting screws to cabinet, making sure mounting screws are in narrow neck of slots. 9. Check that the damper, if used, rotates up and down freely. 10. For vented model installations only: Connect ventwork to hood. Seal joints with clamps to make secure and airtight. Make Electrical Connection WARNING Fire Hazard Electrically ground the blower. Use copper wire. Connect ground wire to green ground screw in terminal box. Failure to do so can result in death, fire, or electrical shock. Direct Wire Installation 1. Connect the white wire of the home power supply cable with the white wire in the range hood using a UL listed wire connector. B A C D E F A. White wires B. Black wires C. Green ground screw D. Ground wire E. UL listed or CSA approved strain relief F. UL listed wire connector 2. Connect the black wire of the home power supply cable with the black wire in the range hood using a UL listed wire connector. 3. Connect ground wire (green or bare) of home power supply cable to the green ground screw in the terminal box. 4. Tighten strain relief screws. 5. Install the terminal box cover. 6. Reconnect power. Complete Installation Install 75-watt (max.) Incandescent Light Bulb 1. Squeeze the plastic lens cover and remove it from the hood. B A A. Light bulb socket B. Lens cover 2. Screw light bulb into socket. 3. Replace lens cover by squeezing cover and inserting tabs into slots. Check Range Hood Operation 1. Check light operation only by pressing light button. 2. Check operation of fan by pressing button to Hi and Lo positions. 3. If the range hood does not operate, check to see whether a circuit breaker has tripped or a house fuse has blown. NOTE: To get the most efficient use from your new range hood, read the “Range Hood Use” section. RANGE HOOD USE The range hood is designed to remove smoke, cooking vapors and odors from the cooktop area. For best results, start the hood before cooking and allow it to operate several minutes after the cooking is complete to clear all smoke and odors from the kitchen. The hood controls are located on the front right-hand side of the range hood. AB A. Fan control B. Light control LIGHTFAN HI LO Range Hood Controls Operating the Light Press light control to turn light on or off. Light may be turned off or on anytime during range hood operation. Operating the Fan Press fan control to turn fan on and off and adjust fan speed. Speed may be increased or decreased anytime during range hood operation. In the U.S.A. RANGE HOOD CARE Call the Whirlpool Customer eXperience Center toll free: 1-800-253-1301. Cleaning IMPORTANT: Clean the hood and grease filters frequently according to the following instructions. Replace grease filters before operating hood. Exterior Surfaces: To avoid damage to the exterior surface, do not use steel wool or soap-filled scouring pads. Always wipe dry to avoid water marks. Cleaning Method: ¦ Liquid detergent soap and water, or all-purpose cleanser ¦ Wipe with damp soft cloth or nonabrasive sponge, then rinse with clean water and wipe dry. Metal Grease Filter: For vented installations: 1. Turn the filter retainer to release filter. A A. Filter retainer 2. Wash metal filters as needed in dishwasher or hot detergent solution. 3. Reinstall the filter by placing the back edge in the channel at rear of hood. Push filter into place, turn the filter retainer to reattach filter to range hood. Non-Vented (recirculating) Installation Filters: The charcoal filter is not washable. Replace with Kit Number 4378581. To replace charcoal filter: 1. Turn the filter retainer to release the charcoal filter. 2. Install new charcoal filter with the blue side against the range hood by placing back edge of filter in channel at rear of range hood. 3. Push filter up into place. Turn the filter retainer to reattach filter to range hood. ASSISTANCE OR SERVICE When calling for assistance or service, please know the purchase date and the complete model and serial number of your appliance. This information will help us to better respond to your request. If you need replacement parts If you need to order replacement parts, we recommend that you use only factory specified parts. Factory specified parts w...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien