Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Delta Electronics, modell ERCE9020AS

Hersteller: Delta Electronics
Dateigröße: 2.69 mb
Dateiname: 469302EN.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


• When using flexible duct always install duct with helix pulled taut to minimise pressure loss. • Failure to observe these basic instructions will drastically reduce the performance and increase the noise levels of the cooker hood. Exhaust air must not be discharged into a wall cavity, unless the cavity is designed for that purpose. The exhaust from the cooker hood must not be discharged into any heating flue, which may carry combustion products from other sources. ERCM9010AS ERCE9020AS 100mm500mm391mmO163mm* 900mm1175mm(maximum) 328mm593mm 100mm500mm391mmO163mm* 900mm1175mm(maximum) 328mm593mm ERCG9030AS 83mm520mm407mmO163mm900mm1275mm(maximum) 331mm698mm Installation sequence 1. Using a spirit level mark a vertical centre line on the wall where the hood is to be positioned, and a horizontal line at the hood base position (refer diagram bottom left). NOTE: The height of the underside of the hood body must be a minimum of 600mm above an electric cooktop & 650mm above a gas cook top and a maximum height of 800mm (see table right). Distance from hood base to top of hob hob type minimum* maximum gas 650mm 800mm electric 600mm 800mm * If the instructions of the hob specify a greater distance than the minimum above, then that shall be the minimum height for installation 2. Mark the location for the wall and ceiling bracket fixing points above the hood base using the hood base as the reference point (refer diagram left). 3. Install wall and ceiling mounting brackets with suitable screws (to support a total weight of 30kg) to the wall at the positions marked in diagram left. 4. Remove the protective plastic film from the hood body and hang hood on the mounting brackets then secure at the anti-tilt locations as indicated in diagram left. Depending on the preferred installation/ducting mode, follow step 5a or 5b below. 5a. Recirculating mode (Fig. a). Using the centre line, secure the ceiling mount bracket to the wall using suitable screws. Attach the recirculating T-piece (optional kit AR600RK for models ERCM9010 and ERCE9020, or AR600RKG for model ERCG9030) to the ceiling mount bracket. Install flexible pipe between T-piece and fan transition outlet. Use cable ties or suitable duct tape to secure flexible pipe to T-piece. NOTE: When installed in recirculation mode, it is recommended to use a carbon filter (included in recirculation kit AR600RK for models ERCM9010AS and ERCE9020AS, or recirculation kit AR600RKG for model ERCG9030AS, refer to page 9) to prevent odours being emitted back into the room. OR 5b. Ducted mode (Fig. b). The canopy rangehood has been supplied with flexible exhaust pipe and duct transition piece, alternatively a 150mm dia. non-combustible flue pipe can be used. Continue the centre line to the ceiling. Attach the ceiling mount bracket on the centre line. Fit preferred flue pipe to the fan transition duct. electrolux e:line rangehoods rangehood installation / installation sequence 5 Rangehood installation 100mm344mm303mm37mm155mm1...

Dieses Handbuch ist für folgende Modelle:
Ventilatoren - ERCE9020AS (2.69 mb)
Ventilatoren - ERCE9020AS (2.69 mb)
Ventilatoren - ERCE9020AS (2.69 mb)
Ventilatoren - ERCG9030AS (2.69 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien