Login:
Stimmen - 5, Durchschnittliche Bewertung: 4.6 ( )

Anleitung KitchenAid, modell Pro LineTM

Hersteller: KitchenAid
Dateigröße: 492.04 kb
Dateiname: 607538d9-ec9c-4f57-a958-6324fb376f08.pdf
Unterrichtssprache:enfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Dieses Gerät hat auch andere Anweisungen:

Anleitung Zusammenfassung


Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting frame must be constructed. Before making cutouts, make sure there is proper clearance within the ceiling or wall for exhaust vent. Check that all the installation parts and the box with filters have been removed from the shipping carton. 1.If possible, disconnect and move freestanding or slide-in range from cabinet opening to provide easier access to rear wall. Otherwise put a thick, protective covering over countertop, cooktop or range to protect from damage or dirt. Select a flat surface for assembling the unit. Cover that surface with a protective covering and place all hood parts and hardware in it. 2.Determine and mark the centerline on the wall where the hood will be installed. If the vent system is already installed, use centerline of vent opening. 3.If venting horizontally out the back of hood and vent system is not installed, mark and cut vent opening now. 4.Important: If used, Backsplash Kit must be installed before installing the hood. If a backsplash is not used, go to Step 5. Backsplash installation: (The hardware package supplied with the kit includes 4 plastic wall anchors and mounting screws.) •The height of the backsplash will determine the height 29-7/8" (75.9 cm) Extends from 19-23/32" (50.1 cm) to 39" (99.1 cm) top of backsplash corner mounting hole (4) 35-7/8" (91.1 cm) 41-7/8" (106.4 cm) 47-7/8" (121.6 cm) 3/8" (9.5 mm) 1" (25.4 mm) of the hood. Note: The minimum height of the hood above the cooktop, as shown on Page 3, is 30" (76.2 cm). The backsplash can be extended from 19-23/32" (50.1 cm) to 39" (99.1 cm). Note: As the 30" (76.2 cm) installation height increases, the hood's capture area decreases. • Determine the height of the hood. • Position the hood on the wall so that the top of the backsplash is at the height of the bottom edge of hood. Mark the location of the four corner holes. It is recommended that the backsplash be attached to the wall at all four corners. However, the lower flange can be secured between the wall and backsplash, countertop or cabinet base without using the bottom corner screws. • Drill 5/16" (8 mm) holes. • Push the plastic wall anchors all the way into the holes. • Position the holes in the backsplash over the wall anchors and attach using the screws supplied. Vent and Electrical openings 2-7/8" 2-7/8" (7.5 cm) 9-11/16" (24.6 cm) 1-1/8" (2.9 cm) 6-3/32" (15.5 cm) 10-1/2" (26.7 cm) Electrical opening Electrical opening CL CL 2-7/8" (7.5 cm) All vent openings are 3-1/4" x 10" (8.3 cm x 25.4 cm) (7.5 cm) 2-7/8" (7.5 cm) 6-3/32" (15.5 cm)30" (76.2 cm) hood 36" (91.4 cm) hood 42" (106.7 cm) hood 48" (121.9 cm) hood 5.The hood attaches to the wall with the mounting screws located as shown. For the 30" (76.2 cm) and 36" (91.4 cm) models, there are two mounting screws. For the 42" (106.7 cm) and 48" (121.9 cm) models, there are four mounting screws. Install the screws into the wall until the screw heads are tight against the wall and horizontal. Note: The screws provided for mounting this range hood must be fastened into solid wood. Do Not fasten into sheet rock only. top of hood 12-9/16" 12-9/16" (31.9 cm) (31.9 cm) 48" (121.9 cm) 1-1/16" min. to cooking surface 30" (76.2 cm) hood (17.5 cm) top of hood 15-9/16" 15-9/16" (39.5 cm) (39.5 cm) 48" (121.9 cm) 1-1/16" min. to cooking surface 36" (91.4 cm) hood (17.5 cm) top of hood 18-9/16" 18-9/16" (47.2 cm) 4-1/4" 4-1/4" (47.2 cm) 1-1/16" (17.5 cm) (10.8 cm) (10.8 cm) 48" (121.9 cm) min. to cooking surface 42" (106.7 cm) hood top of hood 21-9/16" 21-9/16" (54.9 cm)(54.9 cm) 7"7" 1-1/16" (17.5 cm) (17.8 cm) (17.8 cm) 48" (121.9 cm) min. to cooking surface 48" (121.9 cm) hood 5a.Optional vent cover installation: Attach the full-width vent cover to the top of the range hood with the screws provided. The vent cover must be attached to the top of the range hood before mounting the range hood to the wall. CL Top (27.9 cm) of hood 11" A B CL Mounting brackets A 30" (76.2 cm) hood: 13-15/32" (34.2 cm) 36" (91.4 cm) hood: 16-15/32" (41.8 cm) 42" (106.7 cm) hood: 19-15/32" (49.4 cm) 48" (121.9 cm) hood: 22-15/32" (57.1 cm) B 30" (76.2 cm) hood: 26-15/16" (68.4 cm) 36" (91.4 cm) hood: 32-15/16" (83.7 cm) 42" (106.7 cm) hood: 38-15/16" (98.9 cm) 48" (121.9 cm) hood: 44-15/16" (114.1 cm) Install each bracket on the wall as shown. Make sure that the screws and brackets are securely fastened to the wall. Install only the brackets. Do not install the hood. 5b. If chimney extension is used: Attach the extension brackets as shown. 10-5/8" ceiling (27 cm) 8-1/8" (20.6 cm) 8-1/8" (20.6 cm) brackets top of hood 23" (58.4 cm) max. 12" (30.5 cm) min. Make sure that the screws are securely fastened to the wall. 6. Determine and make all necessary cuts in the wall for the vent system. Install the vent system before the canopy hood. See venting methods on Page 4, and hood vent opening dimensions on Page 6. 7. Determine the required heig...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien