|
Anleitung Zusammenfassung
Local building and electrical codes must be adhered to. When this appliance is installed it shall not be used as a space heater. No combustible material or products should be placed on this appliance at any time. Do not spray aerosols in the vicinity of this appliance while it is in operation. Not to be installed in a bathroom or bedroom/sleeping quarters. Flexible appliance connectors shall meet the requirements of ANSI Z21.24 and State Boards. They shall not exceed 36 inches in length. WARNING Electrical Shock Hazard Disconnect power before servicing the product. Failure to do so could result in death or electrical shock. WARNING Cut Hazard Beware of sharp edges. Use the polystyrene ends when carrying the product. Failure to use caution could result in minor injury or cuts. CAUTION! In order to avoid hazard these products must be installed according to these instructions. This product should not be sealed into the bench with silicone or glue. This will make any future servicing difficult. Fisher & Paykel will not be liable for costs associated with releasing such products, nor for damage incurred as a result. IMPORTANT! This product must be installed by an authorized person (WARNING this product must be installed by a licensed plumber or gas fitter when within the Commonwealth of Massachusetts) Please leave these instructions with the appliance. Inform the customer to retain for future reference. This product is supplied with an additional label containing the model and serial numbers. It may be affixed to the underside of the product, the inside of a cupboard or to the User Guide. DIMENSIONS AND CLEARANCES CLEARANCES PRODUCT AND CUTOUT DIMENSIONS A B a US b d c e i h g j f D E H GF gas inlet A B C D E F G H GC36 36” (914mm) 21” (533mm) 15/8" (41.5mm) 191/2" (494mm) [183/8" - 193/4"] 341/4" (870mm) [333/8" - 343/4"] R3/8" (10mm) 13/16" (30mm) 1" (25mm) GC901/GC901M 36” (914mm) 211/2" (546mm) 29/16" (65mm) GC901, 3" (76mm) GC901M 191/2" (494mm) [191/8" - 205/8"] 341/4" (870mm) [337/8" - 351/4"] R3/8" (10mm) 3/4" (20mm) 1" (25mm) CLAMPING DOWN THE COOKTOP Place the cooktop into the cutout and tighten it with the supplied clamps. These will cope with the countertop thicknesses 3/4"- 2" when used in the two orientations shown. Do not over tighten. 3/4" - 2" a 36" = Minimum horizontal distance between overhead cabinets installed on either side of this appliance. b 30" = Minimum clearance from combustible surface centered above the cooktop. c 13" = Maximum overall depth of overhead cabinetry. d 18" = Minimum clearance from countertop to overhead cabinetry. e 4" (GC36) or 11/2" (GC901 & GC901M) = Minimum clearance from cooktop to the left side wall. f 1" = Minimum clearance from cooktop to the right side wall. g 11/2" (GC36) or 11/4" (GC901 & GC901M) = Minimum clearance from cooktop to the rear wall. h 21/2" (GC36) or 11/4" (GC901 & GC901M) = Minimum distance from front edge of counter to front edge of appliance. Where this reduces the distance between the back edge of the appliance and the adjacent wall to less than the minimum of 11/2" (GC36) or 11/4" (GC901 & GC901M), this wall must be of non combustible material (see note below). i 23/8" (GC36) or 35/16" (GC901 & GC901M) = Minimum clearance below countertop to any combustible surface. j 30" = Maximum distance to nearest grounded power outlet from the center of the cooktop. The power cord must not touch any hot metal sufaces. NON COMBUSTIBLE MATERIAL Recommended non combustible materials are: 1/4" (6mm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015” (0.4mm) stainless steel, 0.024” (0.6mm) aluminium or 0.020” (0.5mm) copper. INSTALLATION INSTRUCTIONS US BEFORE YOU START Ensure the countertop is square and level and ensure no structural members interfere with space requirements. Ensure that there is a power supply receptacle (110-120V 60Hz) within reach of the cooktop power cord (30" from the middle of the product). The main cable should not touch any hot metal parts. Make sure the cooktop is connected to a power supply socket that is electrically grounded in accordance with local codes or in the absence of local codes, with the National Electric Code ANSI/FPA 70 or CSA 22.2 (Canada). Make sure the countertop is made of a heat resistant material. We recommend that the exposed bare wood edges of the cutout be sealed with an oil based paint or moisture proof polyurethane to prevent possible damage from moisture creeping between the cooktop trim and the benchtop. We recommend using easy-to-clean finishes for the wall surfaces surrounding the cooktop to aid removal of any cooking stains resulting from use of the cooktop. PARTS CHECKLIST Gas Cooktop base unit Literature pack (includes LPG kit) Elbow & blue washer (taped to power cord) Clamping brackets & screws (GC36-on base unit) Regulator (in Polystyrene) Burner heads and caps (check polystyrene carefully before discarding) 3 x Burner grates/trivets (1 x center, 2 x outer) Acce...
Dieses Handbuch ist für folgende Modelle:Kochfelder - GC901M (1.17 mb)