Anleitung Fisher & Paykel, modell GC9002
Hersteller: Fisher & Paykel Dateigröße: 637.06 kb Dateiname: 530451d_gc_inst.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
These products are registered: in New Zealand at and in Australia with AGA at CAUTION In order to avoid a hazard these products must be installed according to these instructions for installation. Please follow installation information carefully. If in doubt consult your local building regulations, local gas authority codes and electrical regulations. Failure to install the appliance correctly could invalidate any warranty or liability claims and lead to prosecution. The product is to be installed only by a person aurthorised to work on gas installations. WARNINGS This appliance shall be installed in accordance with the installation requirements of the local gas authority or the appropriate installation code issued by the A.L.P.G.A. and A.G.A. (Reference Code AGA 601), or the Building Authorities requirements. Particular attention shall be given to the relevant requirements regarding ventilation. Take care of sharp edges when handling stainless steel products. When this product is installed it shall not be used as a space heater, especially if installed in boats or caravans. No combustible material or products should be placed on this product at any time. Do not spray aerosols in the vicinity of this product while it is in operation. This product should not be sealed into the bench with silicon or glue. This will make future servicing difficult. Fisher & Paykel will not be liable for costs associated with releasing such a product, nor for repairing damage that may be incurred in doing this. BEFORE YOU START DO Prior to installation, ensure that the local distribution conditions (nature of gas and pressure) and the adjustment of the product are compatible. DO Ensure a suitable disconnection switch is incorporated in the permanent wiring, positioned to comply with the Local Wiring Rules and Regulations. DO Ensure the benchtop is square and level and ensure no structural members interfere with space requirements. DO Ensure that there is a 3 pin socket-outlet within reach of the cooktop cable (900mm from rear right of product), this should be accessible after installation. The mains cable should not touch any hot metal parts. DO Make the benchtop of a heat resistant material. CURRENT INFORMATION Current Installation Instructions, Product dimensions and specifications are available on the Fisher & Paykel web site. *Includes Quantum Models Part No. 530451 D February 2003 PRODUCT DIMENSIONS GC600 GC9002CG901M Width 578mm 914mm 914mm Depth 511mm 533mm 546mm Height 40mm 40mm 76mm Note Height measurement below bench surface. CUTOUT DIMENSIONS GC600 GC9002CG901M A Width 560-564mm 846-882mm 860-895mm B Depth 485-495mm 478-501mm 486-524mm C Side Clearances* 140mm 140mm 118mm D Rear Clearance* 100mm 100mm 120mm E Entry from Side 50mm 50mm 25mm F Entry from Back 30mm 30mm 25mm G Clearance Below* 60mm 60mm 81mm Bench *Minimum clearance for cutout to combustible surface. RANGEHOOD CLEARANCE (Dimension A) [See A.G.A. 601 5.12.1.6] Dimension A (Measured from the plane of the pan supports to Rangehood) should not be less than 650mm. Any other downward facing combustible surface less than 600mm above the highest part of the hob shall be protected for the full width and depth of the cooking surface area. However, in no case should this clearance to any surface be less than 450mm. SIDE CLEARANCE (Dimensions B & C) Where Dimension B, measured from the periphery of the nearest burner to any vertical combustible surface, is less than 200mm, the surface shall be protected in accordance with Clause 5.12.1.2 to a Height C of not less than 150mm above the hob for the full dimension (width or depth) of the cooking surface area. Do use easy-to-clean finishes for the wall surfaces surrounding the cooktop to aid removal of any cooking stains resulting from use of the cooktop. A.G.A. Clause 5.12.1.2. A.G.A. Clause 5.12.1.2. Protection of a Combustible Surface Near a Cooking Appliance. The protection required by clause 5.12.1.1. shall ensure the surface temperature of the combustible surface does not exceed 50°C above ambient. Note The fixing of 5mm thick ceramic tiles to the surface or attaching fire resistant materials to the surface and covering with sheet metal with a minimum thickness of 1.4mm would satisfy this requirement. CLAMPING DOWN THE COOKTOP/HOB Place the cooktop into the cutout and tighten it with the supplied clamps. DO NOT OVER TIGHTEN. The clamps will cope with bench thickness 15-50mm (see diagram) when used in the two orientations. Dimensions Clearances When used with a flexible hose, the connector on the wall should be between 800mm to 850mm above the floor and in the region outside the width of the appliance to a distance of 250mm. This should be accessable with the appliance installed. GAS SUPPLY CONNECTION The product is supplied set up for Natural Gas. This cooktop is suitable for installation with Natural Gas, or LP Gas. Refer to table for the relevant pressures and ...