Inform the customer to retain for future reference. Please follow installation information carefully. If in doubt consult your local building regulations, local gas authority codes and electrical regulations. The appliance is to be installed only by an authorized person (in Massachusetts this must be a Massachusetts licensed gas fitter). This product is supplied with an additional label containing the model and serial numbers. It may be affixed to the underside of the product, the inside of a cupboard or to the User Guide. CAUTION IN ORDER TO AVOID A HAZARD THESE APPLIANCES MUST BE INSTALLED ACCORDING TO THESE INSTRUCTIONS. This product should not be sealed into the bench with silicone or glue. This will make any future servicing difficult. Fisher & Paykel will not be liable for costs associated with releasing such products, nor for damage incurred as a result. PAGE 2 OF 6 DO Ensure the countertop is square and level and ensure no structural members interfere with space requirements. DO Ensure that there is a power supply receptacle within reach of the cooktop power cord (30" from the middle of the product). The main cable should not touch any hot metal parts. DO Make sure the cooktop is connected to a power supply socket that is electrically grounded in accordance with local codes or in the absence of local codes, with the National Electric Code ANSI/FPA 70 or CSA 22.2 (Canada). DO Make sure the countertop is made of a heat resistant material. BEFORE YOU START WARNINGS This appliance shall be installed in accordance with the installation requirements of the local gas authority or the appropriate installation code or in the absence of local codes with the latest National Fuel Gas Code ANSI Z223.1 or CAN B149.1,2(Canada). Disconnect power before servicing unit. Be aware of sharp edges when handling stainless steel products. (Carry the product using the polystyrene ends). When this appliance is installed it shall not be used as a space heater. No combustible material or products should be placed on this appliance at any time. Do not spray aerosols in the vicinity of this appliance while it is in operation. Not to be installed in a bathroom or bedroom/sleeping quarters. Flexible appliance connectors shall meet the requirements of ANSI Z21.24 and State Boards. They shall not exceed 36 inches in length. PRODUCT & CUTOUT DIMENSIONS Clamping Down the Cooktop Place the cooktop into the cutout and tighten it with the supplied clamps. These will cope with the countertop thicknesses 5/8"- 2" (see diagram below) when used in the two orientations shown. 36" (914mm) 21" (533.5mm) 15/8" (41.5mm) 5/8" - 2" (15-50mm) bench thickness R 1/4" - 1/2" (5–12.5mm) 34 3/4" - 33 3/8" (882 - 846mm) 19 3/4" - 18 3/8" (501 - 478mm) Manifold Center Line 1" 1 3/16" minimum 2 3/8" (60 mm) 36" (914mm) 211/2" (546mm) GC901: 29/16" (65mm) GC901M: 3" (76mm) R 3/16" - 1/2" (5–12.5mm)35 1/4" - 33 7/ 8" (895 - 860 mm) 20 5/8” - 19 1/8” (524 - 486mm) Manifold Center Line 1" 3/4" 3/4" - 2" (19 - 50 mm) bench thickness minimum 3 5/16" (84 mm) GC36 GC901/M 5/8" - 2" Do not over tighten Clamping Down the Cooktop Place the cooktop into the cutout and tighten it with the supplied clamps. These will cope with the countertop thicknesses 3/4"- 2" (see diagram below) when used in the two orientations shown. 3/4" - 2" Do not over tighten PAGE 3 OF 6 PREPARING THE CUTOUT D B A C F E GC36 Minimum horizontal distances from side and back of appliance to adjacent vertical combustible walls (extending a minimum of 18" (C) from above the top panel) must be 4" from the left side wall, 1" from the right side wall and 1 1/2" from rear wall. Minimum horizontal distance from front edge of counter to front side of appliance 2 1/2" (E). Where this reduces the distance between the back edge of the appliance and the adjacent wall to less than 1 1/2" (F), this wall must be of non combustible material. Minimum clearance from combustible surface centered above cooking surface 30" (A). Minimum horizontal distance between overhead cabinets installed on either side of this appliance 36" (D). Maximum depth of overhead cupboards, 13" (B). These distances shall be from the outermost edge of the top panel. Do use easy-to-clean finishes for the wall surfaces surrounding the cooktop to aid removal of any cooking stains resulting from use of the cooktop. GC901 / GC901M Minimum horizontal distances from side and back of appliance to adjacent vertical combustible walls (extending a minimum of 18" (C) from above the top panel) must be 11/4" from the left side wall, 1" from the right side wall and 11/4" from rear wall. Minimum horizontal distance from front edge of counter to front side of appliance 11/4" (E). Where this reduces the distance between the back edge of the appliance and the adjacent wall to less than 11/4" (F), this wall must be of non combustible material. Minimum clearance from combustible surface centered above cooking surface 30" (A). Minimum horizontal distance between o...