Login:
Stimmen - 3, Durchschnittliche Bewertung: 5 ( )

Anleitung GE, modell CLIMATISEUR AEQ24

Hersteller: GE
Dateigröße: 2.32 mb
Dateiname:
Unterrichtssprache:enesfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Reinstall the locking bracket and screw removed earlier. Reconnect the ground wire to the air conditioner using the screw removed earlier. IMPORTANT: The ground wire must be reinstalled to ensure a proper ground. Press the ground wire against the unit to prevent it from being pinched when installing the front grille Remove the front grille from its box and remove the shipping tape. Grasp the inlet grille at the bottom corners and pull it forward. Unhook it from its top hinges and set it aside. Using the tab, pull up slightly on the filter to release it and pull it down and out. F E D C B 9 A Window Installation Instructions INSTALL THE AIR CONDITIONER IN THE CASE (cont.) Pull the coiled power cord from its shipped position in the air discharge area. Attach the front grille frame to the case by inserting the tabs on the grille frame into the slots on the front top of the case. Press the grille frame in around the power cord on the right side. Secure the grille with a type F (painted) screw on each side and a type C screw in the front. Reinstall the filter. Reinstall the inlet grille. Connect power. Caulk or weather-strip any gaps or openings to the outside to seal the installation. J I H G 9 Guide the lever carefully through the grille frame as you push it in. Type F screw Type F screw Type C screw 14 Through-the-Wall Installation Instructions—Optional 15 The case may be installed through-the-wall in both existing and new construction. Read completely, then follow step-by-step. NOTE: Except for the V-support assemblies (included), obtain all materials locally for mounting the air conditioner through-the-wall. IMPORTANT (cont.) Secure with 14 wood screws anchored at least an inch into the wall support structure. NOTE: Drill pilot holes, if necessary, for proper installation. If the frame is oversized, use shims to prevent case distortion. Install the V-supports. See the INSTALL THE CASE IN THE WINDOW section in the Window Installation Instructions. 1 D E IMPORTANT Through-the-wall installation is not appropriate if any of the side or top louvers in the case will be obstructed by the wall. All side and top louvers in the case must project on the outdoor side of the wall. The room side of the case must project into the room far enough to maximize the balance of the unit. The case must be installed level from side- to-side and with a slight tilt from front to rear. Use a level; no more than a 1/2 bubble will be the correct case slant to the outside. Lintel angle is required to support bricks or blocks above opening. Flashing is required and should extend the length of the opening to ensure no inside cavity leakage occurs. Remove the air conditioner from the case. For specific instruction, refer to the Window Installation Instructions. Make certain that a wall receptacle is available close to the hole location or make arrangements to install a receptacle. 1 A B FINISH THE WALL OPENING Caulk all four sides on the outdoor side of the case to prevent moisture from getting through to the interior wall. Use of flashing (drip rail) will further prevent water from dripping inside the wall and down the outside of the building. 2 Lintel angle Plaster line Trim molding (if desired) INSIDE Bottom rail V-supports Wood filler and caulking (above and below the flashing) Air louvers (top and sides must project on the outdoor side of the wall) OUTSIDE Flashing (Drip rail) Case bottom Bottom rail Caulking A Place the case in the wall opening and place wood support strips between the case bottom and the flashing on both sides of the bottom rail. They should be the same height as the bottom rail and the same length as the wall opening. C Place the air conditioner into the case. For specific instruction, refer to the Window Installation Instructions. Flashing (Drip rail) Wood support strips B Safety InstructionsOperatingInstructionsCare and CleaningInstallationInstructionsTroubleshooting TipsConsumer Support Troubleshooting Tips. Problem Possible Causes What To Do Air conditioner does not start The air conditioner is unplugged. • Make sure the air conditioner plug is pushed completely into the outlet. The fuse is blown/circuit breaker is tripped. • Check the house fuse/circuit breaker box and replace the fuse or reset the breaker. Power failure. • The unit will automatically re-start in the settings last used after the power is restored. • There is a protective time delay (approximately 3 minutes) to prevent tripping of the compressor overload. For this reason, the unit may not start normal cooling for 3 minutes after it is turned back on. The current interrupter device is tripped. • Press the RESET button located on the power cord plug. • If the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician. Air conditioner does not cool as it should Airflow is restricted. • Make sure there are no curtains, blinds or furniture blocking the front of the air cond...

Dieses Handbuch ist für folgende Modelle:
Kochfelder - CLIMATISEUR AEH18* (2.32 mb)
Kochfelder - CLIMATISEUR AEE23 (2.32 mb)
Kochfelder - CLIMATISEUR AEH25* (2.32 mb)
Kochfelder - CLIMATISEUR AEM18* (2.32 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien