Login:
Stimmen - 2, Durchschnittliche Bewertung: 3.5 ( )

Anleitung Cannon, modell C50GCW

Hersteller: Cannon
Dateigröße: 878.7 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


N.B.: in the case of liquid gas, the regulation screw must be screwed in to the bottom. • check that the flame does not turn off when you turn the tap quickly from high to low. d) Regulating the primary air of the burners: The primary air of the burners requires no regulation. Adapting to different types of gas (main and top oven) In order to adapt the oven to a different type of gas with respect to the gas for which it was manufactured (indicated on the label), follow these simple steps: a) Replacing the oven burner nozzle •open the oven door fully •pull out the sliding oven bottom V V Z • Pry the fixing tab “V” and remove the oven burner • Unscrew the oven burner nozzle using the socket spanner for the nozzles “Z”, or a 7 mm socket spanner, and replace it with a nozzle suited to the new type of gas (see Table 1). Take particular care handling the spark plug wires and the thermocouple pipes. • Replace all the parts, following the steps described above in the reverse order. b) Minimum regulation of the main and top gas oven burner with thermostat: • light the burner as described in the paragraph “the oven knob” of the instruction booklet. • turn the knob to Max for about 10 minutes and then turn the knob to the Min setting; • remove the knob; • regulate the screw positioned outside the thermostat pin until the flame is small but steady. N.B.: in the case of liquid gas, the regulation screw must be screwed in to the bottom. • check that the burner does not turn off when you turn the knob from Max to Min and and when you open and close the oven door quickly. Adapting the gas grill to different types of gas Replacing the nozzle of the grill burner: • Remove the enamelled baffle at the front of the grill (2 screws). • Remove the screw on the right hand side of the burner and gently slide the burner off the injector. • Using a 7mm socket, replace the grill injector as appropriate (see table 1). • Re-assemble the burner and baffle. Important On completion of the operation, replace the old rating sticker with one indicating the new type of gas used. This sticker is available from our Service Centres. Note Should the pressure of the gas used be different (or vary) from the recommended pressure, it is necessary to fit a suitable pressure regulator onto the inlet pipe in compliance with current National Regulations relative to “regulators for channelled gas”. Electrial connection Power supply voltage and frequency: 230-240V a.c. 50/60 Hz. Note: the supply cable must be positioned so that it never reaches at any point a temperature 50°C higher than the room temperature.The cable must be routed away from the rear vents. Should you require it, you may use a longer cable, however, you must ensure that the cable supplied with the appliance is replaced by one of the same specifications in accordance with current standards and legislation. Your appliance is supplied with a 13 amp fused plug that can be plugged into a 13 amp socket for immediate use. Before using the appliance please read the instructions below. WARNING - THIS APPLIANCE MUST BE EARTHED. THE FOLLOWING OPERATIONS SHOULD BE CARRIED OUT BY A QUALIFIED ELECTRICIAN. Replacing the fuse: When replacing a faulty fuse, a 13 amp ASTA approved fuse to BS 1362 should always be used, and the fuse cover re-fitted. If the fuse cover is lost, the plug must not be used until a replacement is obtained. Replacement fuse covers: If a replacement fuse cover is fitted, it must be of the correct colour as indicated by the coloured marking or the colour that is embossed in words on the base of the plug. Replacements can be obtained directly from your nearest Service Depot. Removing the plug: If your appliance has a non-rewireable moulded plug and you should wish to remove it to add a cable extension or to re-route the mains cable through partitions, units etc., please ensure that either: • the plug is replaced by a fused 13 amp re-wireable plug bearing the BSI mark of approval. or: • the mains cable is wired directly into a 13 amp cable outlet, controlled by a switch, (in compliance with BS 5733) which is accessible without moving the appliance. Please note: for appliances with a rating greater than 13 amp (eg: electric hob, double ovens and freestanding electric cookers etc.) the mains cable must be wired into a cooker output point with a rating of 45 amp. In this case the cable is not supplied. Disposing of the plug: Ensure that before disposing of the plug itself, you make the pins unusable so that it cannot be accidentally inserted into a socket. Instructions for connecting cable to an alternative plug: Important: the wires in the mains lead are coloured in accordance with the following code: Green & Yellow -Earth Blue -Neutral Brown - Live If the colours of the wires in the mains lead do not correspond with the coloured markings identifying the terminals in your plug, proceed as follows: Connect Green & Yellow wire to terminal marked “E” or or coloured Green or Green & Yellow....

Dieses Handbuch ist für folgende Modelle:
Kochfelder - C50GCS (878.7 kb)
Kochfelder - C50GCIS (878.7 kb)
Kochfelder - C50LCIS (878.7 kb)
Kochfelder - C50GCX (878.7 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien