Anleitung Bionaire, modell BCM4505

Hersteller: Bionaire
Dateigröße: 191.21 kb
Dateiname: 80259a83-cec6-4884-a1d0-df4fc3843d6d.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


The recommended setting is 40-45%. For BCM4505: To maintain Power Light Humidistat Figure 2 this setting, position the humidistat (figure 2) knob in the middle position. Turn the knob clockwise as far as it will turn to achieve the mode refill humidistat power Mode Knob Knob highest humidistat setting. In Refill Light Control Panel this setting, the humidifier will run constantly. To lower your desired humidity level, simply turn the knob counter clockwise to choose your setting. For BCM4509: To take advantage of the SmartTouch™ Electronic Humidistat, press the MODE button until the speed is set in either the HIGH or LOW setting, and the Desired Humidity is set. When the humidity level rises above the set humidity, the humidifier will stop. When the humidity level drops below the set humidity, the humidifier will turn on automatically. NOTE: When the SmartTouch™ Electronic Humidistat is set, either the HIGH or LOW power light and the percent humidity light will remain lit during operation. The SmartTouch™ Humidifier has memory. This means that when you turn the unit back on, it will be at the last setting the humidifier was set at. For BCM4510: The auto setting is designed to operate between 30% and 65% relative humidity range. (The recommended setting is 40-45%.) The auto setting may be used with any of the three auto speed settings (High, Medium or Low). To program a specific humidity level in the auto setting, follow these instructions. 1. Use the mode button to scroll to either Auto/High, Auto/Medium, or Auto/Low. 2. Set the humidifier to the desired room humidity level by pressing the (+) or (–) buttons, in increments of 5%. If you scroll past the maximum setting of 65%, the display will automatically loop back to 30%. 3. Now the desired room humidity level is set. NOTE: When the humidity in the room is less than the level you have programmed, the humidifier will continue to produce moisture. Once the room humidity level has been achieved, the humidifier will turn off. When the room humidity drops below your set level, the unit will automatically begin producing moisture again. . Depending on the size of your room and your personal comfort, you will set your humidistat at different levels. If condensation forms on your windows or walls, or your measured room humidity is above 50%, then turn off your humidifier, or lower your humidistat level. (Humidity can be measured by the use of a hygrometer, such as Bionaire® BT254 or BT400 Digital humidity and temperature monitor. NOTE: Allow up to 30 minutes for the filter to fully absorb water and for the unit to produce moisture. If you do not plan to use the humidifier for two or more days, make sure any residual water is drained from the water tank, base and wick filter to prevent algae or bacteria growth. NIGHTLIGHT INSTRUCTIONS (For BCM4510 Only) the BCM4510 is equipped with a nightlight which illuminates the control panel screen in a dark room setting. This nightlight operates on a sensor, and will illuminate when the room becomes dark. When the room becomes light, the nightlight feature will automatically turn off. To inactivate the nightlight, simply press the nightlight button on the control panel. To re-activate the nightlight feature, simply press the light button again (to see if light is on, place finger over sensor). REFILLING THE WATER RESERVOIR When the water reservoir runs out of water, the refill light will illuminate on the control panel. The fan will continue to run to help dry out the humidifier. Unplug the power cord from the electrical outlet, and follow steps under "Filling the Water Reservoir." If you do not plan to use the humidifier for two or more days, make sure any residual water is drained from the water reservoir, base and wick filter to prevent algae or bacteria growth. REPLACING THE WICK FILTER Through normal use, waterborne minerals and sediment become trapped in the wick filter. The harder your water, the greater the amount of minerals in the water, and the more often you will need to change your wick filter. Filter Monitor (after replacing the wick section) you will be able to check the life of the filter on your humidifier by checking the Filter Monitor located on the moisture outlet. When the unit is not in operation, the Filter Monitor (BCM4505/4509) will also read as OFF. When the unit is turned on, the Filter Monitor needle will need 60 minutes to read the current filter condition. If the needle reads change after 60 minutes, then filter replacement is needed. Regular filter replacement is necessary to ensure optimal humidifier performance. To replace the wick filter, follow the steps below. 1. Turn the mode knob off and unplug the humidifier from the electrical outlet. 2. Remove the water reservoir and humidifier housing to access the base tray. 3. Discard the old wick filter and insert a new wick filter into the filter brackets found in the base. 4. Replace the humidifier housing and then the water reservoir. 5. Repeat...

Dieses Handbuch ist für folgende Modelle:
Luftbefeuchter - BCM4510 (191.21 kb)
Luftbefeuchter - BCM4509 (191.21 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien