|
Anleitung Zusammenfassung
However, before performing any maintenance, consider these important safety precautions: • DISCONNECT ALL ELECTRICAL POWER TO THE HUMIDIFIER AND FURNACE BEFORE PERFORMING ANY SERVICE OR MAINTENANCE TO AVOID PERSONAL INJURY. BEARING RETAINER CABINET PAD PAN Fig. 10— Model HUMBBWTR2019-A- NOTE: THERE MAY BE MORE THAN 1 ELECTRICAL DISCONNECT SWITCH. • ALTHOUGH SPECIAL CARE HAS BEEN TAKEN TO MINIMIZE SHARP EDGES IN THE CONSTRUCTION OF YOUR HUMIDIFIER, BE EXTREMELY CAREFUL WHEN HANDLING PARTS OR REACHING INTO THE UNIT TO AVOID PERSONAL INJURY. Your humidifier has been designed for easy disassembly to simplify cleaning and servicing. Your unit must be kept clean to maintain its efficiency. —3— Regular inspection allows you to determine the cleaning schedule best suited to your humidifier’s operating conditions. The frequency for required maintenance will depend most upon the available water supply. In areas where hard water and high mineral content are prevalent, more frequent cleaning and servicing may be required. At minimum, the humidifier will need to be cleaned at the beginning of every heating season. CLEANING PROCEDURES Models HUMBBLBP, HUMBBSBP, HUMBBLFP, and HUMBBSFP 1. Turn off all electrical power to the humidifier and furnace or fan coil. 2. Turn off the humidifier’s water supply. (See Fig. 4.) 3. Disassemble the humidifier. • To disassemble a Model HUMBBSBP humidifier, gently pull the latch that secures the access panel. Remove the door and slide the evaporator pad assembly out of the unit. (See Fig. 8.) • To disassemble either a Model HUMBBLBP or Model HUMBBLFP humidifier, first remove the water supply connection to the solenoid valve. Next, remove the screw that holds the distributor cover to the cabinet, and lift off the cover. Disconnect the drain line from the sump and loosen the thumbscrew(s) holding the sump to the cabinet. Remove the sump. Remove evaporator pad assembly. (See Fig. 6 or 7, according to the model you own.) • To disassemble a Model HUMBBSFP, the pad assembly can be removed from the side access door or the front cover. When removing the side door, lift the pad assembly up by holding the tabs and slide the assembly out. When removing the front cover on Model HUMBBSFP, disconnect the quick connects to the solenoid valve, unscrew the 4 screws to the front cover, snap loose the top and bottom catches, and lay the front cover aside. Once the front cover is off, lift the pad assembly up and twist it out. The pad assembly consists of 4 parts; the distributor pan, frame, sump, and the evaporator pad. Pull the distributor pan apart from the frame and the evaporator pad can be removed. Do not force the evaporator pad in or out without removing the distributor pan, as this will distort the pad. 4. Clean the humidifier’s external components. • If your humidifier is a Model HUMBBSBP humidifier, wash the access door and outlet drain portion of the cabinet. Make sure the drain is open. • If your humidifier is a Model HUMBBLBP or HUMBBLFP, wash the distributor cover, sump cover, and cabinet. Be sure the inlet ports are open and clean. Then, clean the sump with a solution of detergent and water. 5. Clean the internal components of your humidifier. Wash the distributor pan with a mild detergent and warm water. Be sure holes and slots in the pan are clean and unobstructed. Wash the evaporator pad assembly in a detergent solution. If there are scale deposits on th...
Dieses Handbuch ist für folgende Modelle:Luftbefeuchter - HUMBBLBP2018 (142.88 kb)
Luftbefeuchter - HUMBBSBP2017 (142.88 kb)
Luftbefeuchter - HUMBBSFP1016 (142.88 kb)
Luftbefeuchter - HUMBBWTR2019 (142.88 kb)