on a table, chest, etc. at least 3 ft off the floor. Keep it away from doors or windows. The mist outlet must not be pointed directly at plants or other objects. Keep a distance of at least 20 inches (50cm). WARNING! Do not touch the water in the base during operation! Switch off the unit first. Place the Ionic Silver Stick in the base of the unit. Soak the demineralization cartridge in a water bath 24 hours before the fi rst use; the resin has to absorb water to reach high performance. WARNING! If it is soaked in the tank, make sure to exchange the water and empty the water from the base before using the humidifier. Fill the tank with clean, cold water from the tap. Close the cap of the water tank securely, place the water tank onto the base. The water is now running from the tank into the base. The red empty indicator light may stay illuminated for some seconds until the base is filled with water. Do not pour water into the mist outlet of the appliance. Insert the plug into the socket and switch on the appliance using the on/off switch. The green light comes on. WATER QUALITY MAINTENANCE WITH IONIC SILVER STICK® DO NOT DISCARD! Safe for future reference. Please read the manual or check our website for further information. Lifecycle Indicator Your appliance comes with a lifecycle indicator for changing the Ionic Silver Stick®. To remind yourself when you put the ISS into operation, please cross the current month on the stamp and write the current year on the line provided. Water Quality Maintenance The innovative Ionic Silver Stick® (ISS) uses the proven antimicrobial properties of silver, thereby keeping the water free of harmful microbial growth. The ISS gives off silver ions into the water over a period of more than one year. It is self-renewing and requires no maintenance and no power to function. SOAK CARTRIDGE 24 HOURS BEFORE FIRST USE FILL THE TANK WITH FRESH COLD WATER QUICK SET UP GUIDE 7144 QUICK OPERATION DESCRIPTION 7144 24 h A B C D E F L M K I J G H A On/Off dial B Hygrostat (setting the humidity level) C Timer D Mist output (regulating mist output) E Operation with pre-heating (warm mist) F Automatic mode and Sleep mode G Operating period indicator (1h/2h/3h/4h/5h/6h/7h/8h) H Mist output indicator (LO/ME/HI) I Pre-heating indicator J Automatic mode indicator K Sleep mode indicator L Empty indicator M Cleaning indicator Take off the water tank cap to fill the tank with water. 1 2 3 4 5 6 7 8 9 10 FURTHER INFORMATION RECOMMENDED TO CLEAN WITH EZCal TROUBLE SHOOTING Switch off the appliance and unplug it from the socket before cleaning it. Clean the water tank and the base regularly. Use water only, no detergents. For best results use EZCal custom cleaning agent for AIR-O-SWISS products to remove deposits from the water base regularly. Do NOT run the unit when using EZCal. This can cause damage to the product and voids the warranty. What is EZCal? EZCal from AIR-O-SWISS is an easy and safe cleaning and descaling agent recommended for all humidifiers. It cleans mineral build-up in the water base. There is a sample of EZCal included in the packaging of your humidifier! Only use 1 packet for 32oz of water. Do not change the ratio. Thoroughly rinse the base with tap water and make sure no EZCal residues remain in the base. Instructions for use are on the packet. Please note: EZCal from AIR-O- SWISS is the only recommended cleaning and descaling solution. Do NOT use any other cleaning solutions since it can damage the product. Any use of cleaning solutions apart from EZCal will void the warranty. EZCal descaling agent is available at selected retail stores. ACIDACIDDo not submerge base in water! The cleaning indicator still appears on the display after cleaning. To reset hold down the ON/OFF button until the clean light stops flashing. Thoroughly rinse the base with tap water and make sure no EZCal residues remain in the base! 11 13 30 min 140°F / 60°C 12 AbOUT THE UNIT White dust is emitted from the unit White dust particles are minerals that are broken up in tiny pieces by the ultrasonic process. Solve the problem: • Soak the demineralization cartridge in a bowl of water for a minimum of 24 hours. If the cartridge is soaked in the water tank, the water in the tank and the base needs to be replaced before using the unit. • Exchange the demineralization cartridge after 1– 2 months when you use very hard water, for softer water after 2– 3 months. No matter how hard your water is, exchange the cartridge at the very latest after 6 months. • Don’t use water from a pre-installed water softener, or sodium instead of calcium will be emitted from the unit. Use distilled water instead and remove the demineralization cartridge. • For very hard water areas use only distilled water and remove the demineralization cartridge. • Use reverse-Osmosis water (R-O water) instead of distilled water and remove the demineralization cartridge. Cleaning light is flashing • Switch off the unit and unplug it...