Hersteller: Reliable
Dateigröße: 1.39 mb
Dateiname:
|
Anleitung Zusammenfassung
When the two button lights come on, the steam device and boiler are working. 6. For the i500 iron system, turn the iron plate's temperature regulating knob (6) to the position "cotton 00°” (indicated on the iron knob). 7. Wait 10 minutes for the boiler to reach maximum pressure. Once it reaches 50 psi, the unit is now ready to operate. NOTE: The red light on the boiler switch (4) will turn on and off during use, indicating that the heating element is activated or not. 8. NOTE: When you call for steam for the first time (after having turned the boiler on) you might notice a fast decrease in pressure. This is normal for the first time. 9. The steam station is ready for use. 10. Push the steam button or the foot pedal for steam. 11. This steam product is equipped with a low water warning light (5). During operation, if the light comes on, it indicates that the unit requires more water to operate. If this occurs, please follow these steps. a) Turn off the boiler switch (4). b) Press the steam iron button or foot pedal to ensure there is no more steam in the boiler. c) Slowly open the pressure cap (1) and refill to the required level with warm water. d) Replace the cap, tighten and wait for it to build up pressure again. e) NOTE: Failure to shut off the boiler when the warning light is on may result in damaging the heating element, which will void the warranty. IMPORTANT When you are finished using the boiler for the day, unscrew the fill cap one-turn on the unit to release the steam/air from the tank. This will eliminate the vacuum that may cause damage to the pressure gauge. 05 The boiler must be cleaned periodically and any sediment/mineral buildup removed from inside the unit; otherwise, it may become clogged. The period between cleanings depends on the frequency of use and the quality/hardness of the water used. If the unit is in daily use with regular municipal tap water, we recommend a cleaning every two weeks to a month. TO CLEAN THE BOILER UNIT 1. Unplug the unit from the wall. 2. Disconnect the iron (i500), the steam gun (i500B) or the steam nozzle (i500A) from the boiler unit. (The steam nozzle on the i500A may be left on the unit if desired. It does not affect the cleaning instructions.) 3. Add a mixture of 1 part white vinegar to 5 parts water and pour inside the boiler tank to capacity. Let the vinegar solution sit overnight. 4. Pick up the boiler unit and pour approximately half of the solution out of the boiler tank. Vigorously shake/swirl the remaining solution around the tank to loosen and pick up any softened sediment that may have accumulated inside. Pour the remaining solution out of the tank. You may see bits of sediment and mineral come out at this point. 5. Rinse the tank with clean water until there is no smell of vinegar or any sediment bits coming from inside the tank. NOTE: Sediment/mineral pieces can be blown into the solenoid valve or the steam nozzle during operation so it is important that they are not left in the tank after cleaning. 6. The unit is now ready for use. WATER INSTRUCTIONS Use tap water or 50/50 tap/distilled water in the appliance. Do not use perfume or products containing alcohol in the appliance. 06 DESCRIPTION OF THE i500 1. Safety cap 2. Wand to hold mono-hose up 3. Iron power button 4. Boiler power button 5. Low water level light indicator 6. Temperature regulating knob 7. Steam button 8. Steam regulation knob 9. Manometer / pressure gauge 07 DESCRIPTION OF THE i500A 1. Safety cap 2. Pressure gauge (manometer) 3. Steam button 4. Boiler button 5. Low water light indicator 6. Steam regulating knob 7. Adjustable nozzle 8. Pedal 08 DESCRIPTION OF THE ¡5008 1. Safety cap 2. Pressure gauge (manometer) 3. Steam button 4. Boiler button 5. Low water light indicator 6. Steam regulating knob 7. Cord support 8. Steam switch 9. Steam gun 09 TROUBLESHOOTING PROBLEM POSSIBLE CAUSES REMEDY The steam from the iron is too wet. 1. While filling the tank you may have poured too much water into it. 2. The iron soleplate is not getting hot enough. 1. The problem will go on until the excess water is emptied. Keep the steam button pressed until the water in the tank is at the correct level. 2. Please check that the temperature knob is on the right position, if not, increase the iron temperature. Water is coming out from the boiler. 1. There might be a leak in the heating element gasket. 1. Contact technical support as in most cases, the gasket will need to be replaced. There is no steam coming out of the iron, nozzle or gun. 1. The steam knob might be closed 2. The iron switch might be off 3. The foot pedal is not plugged in (i500A) 4. The boiler switch might be off 5. If the low water light is on, the water in the tank is low or empty. 1. Open the steam knob anticlockwise. 2. After the iron switch comes on, wait for 4 minutes so that the iron plate gets hot. 3. Plug the 4-pin receptacle into the boiler. 4. After the boile...
Dieses Handbuch ist für folgende Modelle:Bügeleisen - I500A (1.39 mb)
Bügeleisen - i500B (1.39 mb)