HP Enterprise BURA Solutions (EBS) Compatibility Matrix - BackUp, Recovery & Archive
IMPORTANT: Consult your ISV / IHV vendor's compatibility guide(s) to confirm ISV / IHV product and operating system version support details. See Page 10 & 11 for hyperlinks to partners websites.
Linux (x64 / x86)
Linux (x64 / x86)
Linux (x64 / x86) 5
Direct Attached and SAN Support
Version
Direct Attached and SAN Support
Version
Direct Attached and SAN Support
Version
Operating Systems
16Gb Fibre Channel Host Bus Adapters (HP Branded / Third Party)
4Gb Fibre Channel Host Bus Adapters 6 (HP Branded / Third Party)
RHEL [AS/ES/WS] 6 (x64 / x86) 1
Update 4
SN1000Q (QW971A, QW972A) (PCI-e)
FC1142SR (AE311A) / QLogic QLE2460 & FC1242SR (AE312A) / QLogic QLE2462 (PCI-e)
RHEL [AS/ES/WS] 5 (x64 / x86) 1, 2
Update 10
RHEL 5, 6 FW
6.07.02
FW
5.03.15
SLES 11 (x64 / x86)
SP2
SLES 11 FW
6.02.20
RHEL 5 FC driver 10
8.03.07.15.05.10-k (Inbox)
SLES 10 (x64 / x86) 2
SP4
RHEL 5 FC driver 4
8.06.00.03.5.6-k2
RHEL 6 FC driver
8.04.00.12.06.0-k2
Servers
RHEL 6 FC driver
8.04.00.12.06.0-k2(OOB)
SLES 10 FC driver
8.04.00.06.10.3-k
HP ProLiant & BladeSystem c-Class

SLES 10 FC driver
8.04.00.09.10.3-k2
SLES 11 FC driver
8.04.00.12.11.1-k2 (OOB)
Third Party

SLES 11 FC driver
8.04.00.12.11.1-k2 (OOB)
FC2142SR (A8002A) / Emulex LPe1150 & FC2242SR (A8003A) / Emulex LPe11002 (PCI-e)
10GbE Converged Network Adapters (HP Branded)
SN1000E (QR558A/QR559A) (PCI-e)
FW
2.82x4
CN1000E (AW520A) (PCI-e)
iSCSI support only
FW
1.1.62.0
RHEL 5 FC driver 10, 13
8.2.2.33
CN1000Q (BS668A) / 526FLR (629138-B21) (PCI-e)
RHEL 5 FC driver 4
8.2.2.33
RHEL 6 FC driver
8.3.7.39
FW 3
4.14.25(OOB)
RHEL 6 FC driver
8.3.7.39
SLES 10 FC driver
8.2.0.145.4p
RHEL 5 FC driver 4
8.04.00.12.5.6-k2
SLES 10 FC driver
8.2.0.145.4p
SLES 11 FC driver
8.3.7.39
RHEL 6 FC driver
8.04.00.12.06.0-k2
SLES 11 FC driver
8.3.7.39
41B (AP767A/B) / Brocade 415 & 42B (AP768A/B) / Brocade 425 (PCI-e)
SLES 10 FC driver
8.04.00.06.10.3-k
SN1100E (C8R38A/C8R39A) Emulex (LPe16000B/LPe16002B) (PCI-e)
FW
3.2.1.0(OOB)
SLES 11 FC driver
8.04.00.12.11.1-k2 (OOB)
FW
1.1.62.0
RHEL 5 FC driver 10
3.0.23.0 (Inbox)
RHEL 5 SLES 10,11 NIC Driver
5.0.29.5 (OOB)
RHEL 5 FC driver 4
8.2.2.33
RHEL 6 FC driver
3.2.1.0(OOB)
RHEL 6, SLES 10,11 NIC Driver
5.0.29.3 (OOB)
RHEL 6 FC driver
8.3.7.39
SLES 10 FC driver
3.2.1.0(OOB)
RHEL 5,6, SLES 10,11 iSCSI Driver
5.03.01.11-3
SLES 10 FC driver
8.2.0.145.4p
SLES 11 FC driver
3.2.1.0(OOB)
CN1100E (BK835A) (PCI-e) / 554FLR (FlexibleLOM, 629142-B21)
SLES 11 FC driver
8.3.7.39
FC1143 (AB429A) / QLogic QLA2460 & FC1243 (AE369A) / QLogic QLA2462 (PCI-X 2.0)
FW 3
4.9.311.20
16Gb HP BladeSystem c-Class Fibre Channel Host Bus Adapters
FW
5.03.15
RHEL 5 FC driver 4
8.2.2.33
QMH2672(710608-B21) (PCI-e)
RHEL 5 FC driver 10
8.03.07.15.05.10-k (Inbox)
RHEL 6 FC driver 5
8.3.7.39
FW
6.07.02
RHEL 6 FC driver
8.04.00.12.06.0-k2
SLES 10 FC driver
8.2.0.145.4p
RHEL 5 FC driver 4
8.06.00.03.5.6-k2
SLES 10 FC driver
8.04.00.06.10.3-k
SLES 11 FC driver (Only supported with SP1
8.3.7.39
RHEL 6 FC driver
8.04.00.12.06.0-k2(OOB)
SLES 11 FC driver
8.04.00.12.11.1-k2 (OOB)
RHEL 5,6, SLES 10,11 NIC Driver
4.9.311.1-1
SLES 10 FC driver
8.04.00.09.10.3-k2
FC2143 (AD167A) / Emulex LP1150 & FC2243 (AD168A) / Emulex LP11002 (PCI-X 2.0)
RHEL 5 iSCSI Driver
4.9.196.1007-1
SLES 11 FC driver
8.04.00.12.11.1-k2 (OOB)
FW
2.82x4
RHEL 6, SLES 10,11 iSCSI Driver
4.9.311.4-1
8Gb Fibre Channel Host Bus Adapters (HP Branded / Third Party) 6
RHEL 5 FC driver 10, 13
8.2.2.33
CN1100R (QW990A) (PCI-e) / 534FLR (700751-B21)
81Q (AK344A) / QLogic QLE2560 & 82Q (AJ764A) / QLogic QLE2562 (PCI-e)
RHEL 6 FC driver
8.3.7.39
FW 3
7.8.79
FW
5.09.00
SLES 10 FC driver
8.2.0.145.4p
RHEL 6 FC driver 5
2.4.1e (OOB)
RHEL 5 FC driver 7
8.04.00.12.5.6-k2 (OOB)
SLES 11 FC driver
8.3.7.39
SLES 11 FC driver
2.4.1e (OOB)
RHEL 6 FC driver
8.04.00.12.06.0-k2
4Gb HP BladeSystem c-Class Fibre Channel Host Bus Adapters 6
RHEL 6, SLES 11 NIC Driver
1.78.80
SLES 10 FC driver
8.04.00.06.10.3-k
LPe1105 (403621-B21) (PCI-e) for HP BladeSystem c-Class
RHEL 6, SLES 11 iSCSI Driver
0.7.8.1e-1
SLES 11 FC driver
8.04.00.12.11.1-k2 (OOB)
FW
2.82x4
10GbE HP BladeSystem Converged Network Adapters (HP Branded)
81E (AJ762A & AJ762B) / Emulex LPe12000 & 82E (AJ763A & AJ763B) / Emulex LPe12002
RHEL 5 FC driver 10
8.2.2.33
NC551m (580151-B21) & NC551i (PCI-e)
iSCSI support only
FW
2.01a12
RHEL 6 FC driver
8.3.7.39
NC553m (613431-B21) / NC553i / 554M (647590-B21) / 554FLB (647586-B21) (PCI-e)
RHEL 5 FC driver 7
8.2.2.33
SLES 10 FC driver
8.2.0.145.4p
FW 3
4.9.311.20
RHEL 6 FC driver
8.3.7.39
SLES 11 FC driver
8.3.7.39
RHEL 5 FC driver 4
8.2.2.33
SLES 10 FC driver
8.2.0.145.4p
QMH2462 (403619-B21) (PCI-e) for HP BladeSystem c-Class
RHEL 6 FC driver
8.3.7.39
SLES 11 FC driver
8.3.7.39
FW
5.03.15
SLES 10 FC driver
8.2.0.145.4p
81B (AP769A & AP769B) / Brocade 815 & 82B (AP770A & AP770B) / Brocade 825 (PCI-e)
RHEL 5 FC driver 10
8.03.07.15.05.10-k (Inbox)
SLES 11 FC driver (Only supported with SP1
8.3.7.39
FW
3.2.1.0(OOB)
RHEL 6 FC driver
8.04.00.12.06.0-k2
RHEL 5,6, SLES 10,11 NIC Driver
4.9.311.1-1
RHEL 5 FC driver 7
3.0.23.0 (Inbox)
SLES 10 FC driver
8.04.00.06.10.3-k
RHEL 5 iSCSI Driver
4.9.196.1007-1
RHEL 6 FC driver
3.2.1.0(OOB)
SLES 11 FC driver
8.04.00.12.11.1-k2 (OOB)
RHEL 6, SLES 10,11 iSCSI Driver
4.9.311.4-1
SLES 10 FC driver
3.2.1.0(OOB)
SAS - Third Party HBAs and Integrated Controllers
NC534M (700748-B21) / 534FLB (700741-B21) (PCI-e)
SLES 11 FC driver
3.2.1.0(OOB)
LSI 9212-4i4e (6Gb, PCI-e) 12

FW 3
7.8.79
8Gb HP BladeSystem c-Class Fibre Channel Host Bus Adapters 6
SAS Host Bus Adapters and Controllers
RHEL 6 FC driver 5
2.4.1e (OOB)
QMH2572 (651281-B21) / QMH2562 (451871-B21) (PCI-e) for HP BladeSystem c-Class
P721m, P731m16 (6Gb, PCI-e) for BL Gen8 servers only

SLES 11 FC driver
2.4.1e (OOB)
FW
P222, P430, P4205, P431, P421, P822, H220, H221, H222
5.09.00

(6Gb, PCI-e)
RHEL 6, SLES 11 NIC Driver
1.78.80
RHEL 5 FC driver 7
8.06.00.03.5.6-k2
P212, P4108, P411, P711m, P712m, P812 (6Gb, PCI-

RHEL 6, SLES 11 iSCSI Driver
0.7.8.1e-1
RHEL 6 FC driver
8.04.00.12.06.0-k2
P700m, P800, SC44Ge (3Gb, PCI-e)

NOTES:
SLES 10 FC driver
8.04.00.06.10.3-k
SCSI Host Bus Adapters 14
1) RHEL kernel versions include support for Oracle Enterprise Linux (OEL).
SLES 11 FC driver
8.06.00.03.11.1-k
412911-B21 (HP SC11Xe, Ultra320, PCI-e, 1 channel)

2) Only in-box HBA drivers and device-mapper multipathing are supported with
LPe1205A (659818-B21) / LPe1205 (456972-B21) (PCI-e) for HP BladeSystem c-Class
SCSI - Third Party HBAs and Integrated Controllers 9
RHEL 5 Update 3, SLES 10 SP3 and newer.
FW
2.02x6
Adaptec 29320ALP-R (Ultra320, PCI-X, 1 channel)11

3) Minimum FW required for FCoE support.
RHEL 5 FC driver 7
8.2.2.33
ATTO Express PCI UL4D (Ultra320, PCI-X, 2 channel)

4) ARCserve: In RH5 when the 'udev' service is starting it will send a rewind command to any
RHEL 6 FC driver
8.3.7.39
ATTO Express PCI UL5D (Ultra320, PCI-e, 2 channel)

unreserved loaded tape drive in the shared SAN Environment.
SLES 10 FC driver
8.2.0.145.4p
5) ARCserve: If using the Emulex OCM (One Command Manager), DO NOT enable "sensor
SLES 11 FC driver
8.3.7.39
NOTES CONTINUED
kits" during OCM installation.
804 (590647-B21) (PCI-e) for HP BladeSystem c-Class
11) Supported with LTO-4 SCSI only
6) Third Party adapters require HP drivers and firmware.
FW
3.2.1.0(OOB)
12) Recommended for use with HP workstations and third party servers.
7) ARCserve: In RH5 when the 'udev' service is starting it will send a rewind command to any
RHEL 5 FC driver 7
3.0.23.0 (Inbox)
13) LTO-5 requires Emulex inbox driver version 8.2.0.66 or newer.
unreserved loaded tape drive in the shared SAN Environment.
RHEL 6 FC driver
3.2.1.0(OOB)
14) Third party servers supported with HP-branded adapters only.
8) SAS Expander card 468406-B21 is required to connect external tape.
SLES 10 FC driver
3.2.1.0(OOB)
15) TSM and NetWorker: P212 Zero Memory HBA supported with v7.6.1.1 or later.
9) Third Party SCSI HBA support is for HP servers only.
SLES 11 FC driver
3.2.1.0(OOB)
For NetWorker 7.5.4, supported with v7.5.4.6 or later.
10) ARCserve: In RH5 when the 'udev' service is starting it will send a rewind command
16) Not supported by SLES 10
to any unreserved loaded tape drive in the shared SAN Environment.


...