Saving HSG60 Configurations to Previously Initialized Storagesets
1. This application is supported by IBM AIX, HP-UX, OpenVMS, Sun Solaris,
Tru64 UNIX, and Windows.
2. This application is supported by IBM AIX, Novell Netware, OpenVMS, Sun
Solaris, Tru64 UNIX, and Windows.
For more information on these and other Storage Management software, see the
product documentation that comes with the product, or visit the following HP
website:
http://www.hp.com/storage/software_index.html
Saving HSG60 Configurations to Previously Initialized
Storagesets
If any storageset within the configuration was previously initialized with the
INITIALIZE container-name SAVE_CONFIGURATION command to
save your configuration to disk, it will not be necessary to reconfigure your
devices with a new HSG60 controller. SAVE_CONFIGURATION also retains
code patch information to the software. This option is supported on single
controller configurations only.
ACS V8.8 saves any installed software patches on disks initialized with the
SAVE_CONFIGURATION option. To replace a controller and restore the
configuration from a disk, you will not have to reinstall any software patches.
Configuration information cannot be retrieved from storagesets created on other
HSx controllers (for example, HSD, HSJ, or HSZ controllers). You can only
restore a configuration from a configuration saved on HSG60 array controllers.
SWCC Client Instal ation
SWCC employs different applets for different controllers. The SWCC client
installation will differ between HSG60 and HSG80. The SWCC Agent and HBA
drivers are identical for HSG60 and HSG80 array controllers.
SCSI Bus Limitation
The array controller firmware can address up to 14 disks per SCSI bus.

Since the HSG60 array controller has two SCSI buses, the maximum number
of disks supported is 28. The SCSI-2 bus can not be configured split-bus.
8
HSG80 Addendum for ACS Solution Software V8.8 Differences Between HSG60 and HSG80
Array Controllers


...

Dieses Handbuch ist für folgende Modelle:
Media Storage - HP StorageWorks EMA12000 Blue (60 Hz) (308.61 kb)
Media Storage - HP StorageWorks EMA12000 Blue Bundle (50 Hz) (308.61 kb)
Media Storage - HP StorageWorks EMA12000 Blue Bundle (60 Hz) (308.61 kb)
Media Storage - HP StorageWorks EMA12000 D14 (60 Hz) (308.61 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien