Login:
Stimmen - 0, Durchschnittliche Bewertung: 0 ( )

Anleitung HP, modell HP MSA70 Array

Hersteller: HP
Dateigröße: 470.16 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Dieses Gerät hat auch andere Anweisungen:

Anleitung Zusammenfassung




MSA7X Series Enclosure

About this document
Midplane replacement
This document details procedures for replacing a failed
instructions
midplane in an MSA7X Series Enclosure.

Before you begin
For updates, visit the HP website:
CAUTION: Before removing the failed component, make sure
http://www.hp.com/support/manuals.
that you have the replacement part available. Removing a

component impacts the airflow and cooling ability of the
device.
To prevent improper cooling and thermal damage, do not
operate the storage enclosure unless all bays are populated
with either a component or a blank.

Do not remove more than one component or blank from the

enclosure at a time. Doing so impacts the airflow and cooling

ability of the device. To avoid possible overheating, insert the
new or replacement component as quickly as possible. If the

internal temperature exceeds acceptable limits, the enclosure

may overheat and automatically shut down or restart.

Parts can be damaged by electrostatic discharge. Use proper
anti-static protection.



Verifying component failure

Before replacing the midplane, use the following methods to

verify component failure:


Check the following component status LEDs as identified in

the following tables:
• Hard drives—test with known good hard drives.

• I/O module—test with known good I/O module.

• Fan module—test with known good fan module.


Check the host log for errors.


Hard drive LED combinations

Online/activity LED Fault/UID LED
Interpretation

(green)
(amber/blue)

On, off, or flashing Alternating amber
The drive has failed, or
and blue
a predictive failure

alert has been received

for this drive; it also
has been selected by a

management
© Copyright 2007 Hewlett-Packard Development Company, L.P.
application.
The information contained herein is subject to change without notice.
On, off, or flashing Steadily blue
The drive is operating
The only warranties for HP products and services are set forth in the
normally, and it has
express warranty statements accompanying such products and services.
been selected by a
Nothing herein should be construed as constituting an additional
management
warranty. HP shall not be liable for technical or editorial errors or
application.
omissions contained herein.
On
Amber, flashing
A predictive failure
Part number: 436512-001web
regularly (1 Hz)
alert has been received
First edition: 02/2007
for this drive.
Replace the drive as
*436512-001*
soon as possible.

On Off The drive is online, but

it is not currently active.


...

Dieses Handbuch ist für folgende Modelle:
Media Storage - HP MSA70 Dual Domain (25) 300GB 2.5-inch DP SAS HDD 7.5TB Bundle (470.16 kb)
Media Storage - HP StorageWorks MSA70 with 25 72GB SAS SFF 1.8TB Bundle (470.16 kb)
Media Storage - HP StorageWorks MSA70 with 25 146GB SAS SFF 3.6TB Bundle (470.16 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien