Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung Heath Zenith, modell Motion Sensing Diecast Metal Lantern 9600LED series

Hersteller: Heath Zenith
Dateigröße: 626.09 kb
Dateiname: 64430ef0-8e50-40e3-b0af-92108517c5e0.pdf
Unterrichtssprache:enesfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


• Automatically turns light off. • Photocell keeps the light off during daylight hours. Requirements • The light control requires 120 volts AC. • If you want to use Manual Override mode, the control must be wired through a switch. NOTICE: Not to be used on light dimmer or timer- controlled circuits. • Some electrical codes require installation by a qualified electrician. • This light fixture has been tested/certified using Lights of America LED Lamp Model No. 2025LEDE12. Unpacking Be sure to remove all contents from packaging and verify all items are present before assembling this light fixture. This package includes the following items: • Lantern • Three LED Lamps (Lights of America Model: 2025LEDE12) • Universal mounting bracket (X-Bar) • Mounting hardware • Wire nuts • Owner’s Manual INSTALLATION For best performance, mount the fixture about 6 feet (1.8 m) above the ground. 1. Remove two decorative nuts. 2. Remove X-Bar. 3. Tighten mounting screws on X-Bar finger tight. 4. Attach X-Bar to junction box. X-Bar Lantern Base Decorative Nut Lantern Mounting Screw Junction Box X-Bar Bracket Mounting Screw Note: We recommend having an assistant help hold the lantern assembly during the wiring process. © 2008 598-1338-03 598-1338-03 2 Wiring Connect the fixture wires to the wires in the junction box. Twist the wires together and secure with wire connectors. WARNING: Turn power off at circuit breaker or fuse. Note: All wiring should be run in accordance with the National Electrical Code through conduit or another acceptable means. Contact a qualified electrician if there is any question as to the suitability of the system. Recommended Grounding Method Use a green ground “pigtail” (not provided) and twist one end together with the bare fixture wire and the box ground wire. Secure with a wire connector. Secure the other end of the “pigtail” with the GND screw on the X-bar. CAUTION: DO NOT connect the RED wire unless you want to control other lights from the motion sensor (see Optional Wiring). Black Light Fixture Green or Bare White One Motion Light White Black to black Light Fixture Light Fixture White to white If you have metal junction box, you may not need the green “pigtail”. If you are unsure about the grounding method, consult your local building code. Black Green or Bare Two Motion Lights 3 598-1338-03 OPTIONAL WIRING This fixture is provided with a sensor rated for 360 Watts. Since the fixture is only rated 180 Watts, 180 Watts of additional lighting may be controlled by this sensor. When determining what a fixture is rated for, do not simply look at the rating on the lamp in the fixture. Look at the marking which specifies the maximum lamp wattage for which the fixture is suitable. Once you have selected the fixtures to be connected and determined their maximum ratings, add these ratings up. For instance, if you have 3 fixtures rated 180 Watts, 100 Watts, and 75 Watts respectively, you have a total load of 355 Watts. Wiring Diagram 1 – When wiring to control a standard light fixture: Strip the motion sensor’s red wire and connect to the standard light’s black wire. Connect all white wires together. Total fixture ratings must not exceed 360 Watts (3.0 A). Wiring Diagram 2 – When wiring to control another motion sensing light fixture (Master / Slave): Strip the red wire in both light fixtures. Connect the red wire of the controlling (master) fixture to the red and black wires of the controlled (slave) fixture. Connect all white wires together. Total fixture ratings must not exceed 360 Watts (3.0 A). Wiring Diagram 3 – When wiring so either motion light turns on the both motion lights (Master / Master): Strip the red wire in both light fixtures. Connect the red wire of one fixture to the red wire of the second fixture. Note: In most installations, an additional wire (same gage as existing house wire) will have to be installed in the house to connect the two fixtures as master / master. Connect all white wires together and all black wires together. Total fixture ratings must not exceed 360 Watts (3.0 A). Slave Master (Standard) White White Light Fixture Light Fixture Light Fixture Light Fixture Red Red Black Black Green or Bare Green or Bare Wiring Diagram 1 Wiring Diagram 2 Master Master White Red Light Fixture Light Fixture Black Green or Bare Wiring Diagram 3 Final Assembly 1. Push the wires into the junction box. Make sure none of the wires get pinched. 2. Slide the fixture assembly onto the mounting screws. Tighten decorative nuts removed in step 1 of Installation section securely against fixture base. 3. Caulk around fixture base with silicone weather sealant. 4. Install the three LED Lamps (Lights of America Model No. 2025LEDE12 included). Note: This fixture’s E12 candelabra base uses either LED Lamps (1.5W maximum each) or tungsten incandescent Type “B” bulbs (60 Watt maximum each). 5. Insert threaded rod of finial through top cover. Slide star washer onto rod and thread the nut onto the rod. Tighten ...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien