Anleitung Invacare, modell MicroAIR MA55

Hersteller: Invacare
Dateigröße: 2.06 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Refer to the owner’s manual provided with the bed. 2. Engage the wheel locks of the wheelchair, if applicable. Refer to the owner’s manual provided with the wheelchair. 3. Press the Max Inflate or Mode button to achieve maximum mattress pressure. 4. Raise or lower the bed to match the wheelchair height. Refer to the owner’s manual provided with the bed. 5. When the mattress has reached maximum firmness, perform one of the following: • Bed to Wheelchair Transfer - Slide the patient onto the wheelchair. • Wheelchair to Bed Transfer - Slide the patient onto the bed. 4.10 Preparing for CPR Procedure • For this procedure, refer to FIGURE 6 on page 28. 1. Press and hold the tabs on hose connector while pulling the hose from the control unit. 2. Disconnect the RED CPR connector located on the side of the mattress. Part No 1148136 27 Invacare® MA50 Series 4 OPERATION Control Unit Connectors Tab Hose Connector Hose RED CPR Connector Mattress FIGURE 6 Preparing for CPR Procedure 4.11 About Power Outage and Transportation If the hoses remain connected to the control unit, the mattress retains air during a power outage, during transportation, when the control unit is unplugged or when the control unit is turned Off. If the hose becomes disconnected or damaged and the mattress deflates, the mattress has a 2-inch foam pad to provide patient support. Invacare® MA50 Series 28 Part No 1148136 5 MAINTENANCE AND TROUBLESHOOTING 5 Maintenance and Troubleshooting 5.1 Cleaning the System WARNING . Before cleaning or disassembling the MA50 series, check the underside of the mattress folds for sharp objects such as scissors, needles, etc. These objects should be removed and discarded before proceeding with further cleaning or disassembly; otherwise injury or damage to the product may occur. Because of potential risk of infectious exposure, cleaning with the patient on the bed is not recommended. All equipment should be inspected. Any item that is visibly soiled with the patient's blood or other body fluids should be properly cleaned or removed. Laundry workers should treat all soiled bedding as if it were contaminated with pathogenic microorganisms. 1. Remove the bedding. 2. If necessary, inflate the mattress. 3. Ensure that the control unit is off. 4. Unplug the power cord from the wall outlet. 5. Ensure that the underside of the mattress is clear of all sharp objects. 6. Examine the surface of the control unit and mattress assembly components for visible blood or body fluids. 7. Perform one of the following: • If blood is present, decontaminate the product. i. Remove all visible soil with disposable paper towels. ii. Scrub the area with freshly prepared effective detergent disinfectant solution. • If blood is not present, remove any soil from the cover with paper towels. Part No 1148136 29 Invacare® MA50 Series 5 MAINTENANCE AND TROUBLESHOOTING • If soiled, the cover should be removed, cleaned and decontaminated. 8. Perform the following steps to clean the mattress cover: A. Using a clean sponge or paper towel, wipe down the cover surface with a dilute detergent solution of quaternary cleaner disinfectant or other germicidal detergent solution. B. Remove the cover and launder it using the following method: CAUTION . Laundry workers should always wash their hands before working with clean bedding. DO NOT overload the machine. DO NOT use chlorine bleach because it may damage the fabric coating. High air temperatures will damage the fabrics and void the Invacare warranty. i. Place the cover in a washing machine. ii. Wash with warm water (below 120°F). iii. Add detergent and disinfectant according to the manufacturer’s instructions. iv. Remove excess water. v. Set the dryer to the lowest setting (below 120°F). vi. Dry the cover until it is completely dry. 9. Perform the following steps to clean the control unit and hose fittings: A. Wipe all controls, chassis and hose fittings with a quaternary disinfectant solution. B. Using a nylon brush, gently clean all crevices as they can harbor microorganisms. C. Air dry all treated surfaces. Invacare® MA50 Series 30 Part No 1148136 5 MAINTENANCE AND TROUBLESHOOTING 10. Perform the following steps to clean the mattress components (air cushions, mattress base, etc.): A. Using a clean sponge or paper towel, wipe down the mattress components with a dilute detergent solution of quaternary cleaner disinfectant or other germicidal detergent solution. B. Wipe the mattress components with a clean dry cloth. Storing the System 1. Ensure that the control unit is off and disconnect the power cord from the wall outlet. 2. Clean the system. Refer to Cleaning the System on page 29. 3. Disconnect the air hose connector(s) from the control unit and allow air to vent from the mattress. 4. Gently roll up the mattress with minimal handling and agitation. 5. Ensure the cover surface is inside the roll. 6. Store the unit, keeping the mattress with the control unit. Part No 1148136 31 Invacare® MA50 Series 5 MAINT...

Dieses Handbuch ist für folgende Modelle:
Camping - MicroAIR MA50 (2.06 mb)
Camping - MicroAIR MA51 (2.06 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien