This will deactivate the Max Inflate LED. It is recommended that Max Inflate setting be used during patient ingress/egress, patient wound care, patient turning or patient cleaning. • Low Air Loss Mode - In this mode, the mattress goes into on-demand low air loss relief mode. Invacare® MA90Z Series Mattresses 24 Part No 1148139 4 OPERATION Max Inflate Button (MA95Z Power Unit) 1. Press the Max Inflate button ( ) to select the max inflate mode and inflate the mattress rapidly to maximum firmness (pressurized to 35 ± 6 mmHg). A series of beeps sound every three minutes as a reminder that the Max Inflate mode is active. After 15 minutes, the Max Inflate mode deactivates and the control unit defaults to the previous setting. It takes 25-60 seconds for the MA95Z mattress to inflate fully (inflation time depends on size of mattress). • It is recommended that Max Inflate setting be used during patient ingress/egress, patient wound care, patient turning or patient cleaning. 2. Perform one of the following: • MA90Z Power Unit - Press the Max Inflate button again to manually disengage Max Inflate mode. • MA95Z Power Unit - Select a different setting to exit Max Inflate mode, or press the Max Inflate button again. • This will deactivate the Max Inflate LED. Lock/Alarm Silence Button 1. Press the Lock/Alarm Silence button ( ) to select one of the following modes: • Lock Mode - Pressing this button locks out all control unit functions, including the On button, to prevent any tampering with the settings. Press the button for approximately 3-5 seconds for the Lock LED to activate. • The Lock LED illuminates when in this mode. • Alarm Silence mode - Pressing this button silences the alarm that sounds in the event of power failure or when the hose is disconnected from the control unit. • The Alarm LED illuminates when in this mode. Part No 1148139 25 Invacare® MA90Z Series Mattresses 4 OPERATION Power Fail LED In the event of power outage, an alarm sounds and the Power Fail LED flashes AMBER. The control unit has internal memory and retains the previous settings during the power outage. During a power outage, the MA90Z, MA90ZB42 and MA90ZB48 mattress retains the air as long as the mattress is • connected to the control unit. Low Pressure LED In the event that the mattress hose disconnects, an alarm sounds and Low Pressure LED flashes AMBER. Once the low pressure problem is fixed, the control unit resumes operation in the previously set mode. Displaying the Total Run Time (MA95Z Power Unit) Every time the control unit is plugged in, the LCD screen displays the Run Time in hours and minutes. For example, 2,584 hours and 25 minutes displays as 002584 Hours 000025 Minutes. To display the Run Time during use: 1. Ensure the control unit is plugged in and the Standby LED is On. 2. Press and hold the Soft and Firm Buttons at the same time. 3. The LCD screen displays the Run Time as described above. 4.7 Powering Up the System • For this procedure, refer to FIGURE 4 on page 19. 1. Turn on the power to the system by pressing the Power button on the control unit. • Once the button is released, a green led illuminates when the unit is on. Invacare® MA90Z Series Mattresses 26 Part No 1148139 4 OPERATION 4.8 Placing the Patient on the Mattress 1. Press the Mode button or Max Inflate button to turn on the control unit to maximum flow. • In this mode, the Max Inflate Led lights up. 2. After the mattress is fully inflated, place the patient on the bed. 3. Ensure that the patient’s feet are towards the foot end of the mattress (the end with the hose). 4. Center the patient on the bed from side-to-side and head-to-foot. • Special positioning may be required with contracted patients to provide comfortable positions. 5. After placing the patient, make certain no objects will fall under the patient, such as feeding tubes, IV's etc. 6. Wait five minutes for the mattress pressure to stabilize. 7. Set the comfort pressure to the desired comfort level. 8. Verify that the patient has not bottomed out by performing the following steps: A. Ensure that the patient is lying flat on his/her back in the middle of the mattress. B. Place four fingers between the air cushions directly underneath the sacral region of the patient’s body. C. Ensure that there is 3 to 4-finger width clearance between the bottom of the patient and the bed frame. D. Adjust the comfort setting, if needed. E. Wait five minutes for the mattress pressure to stabilize. F. Repeat STEPS A-E until patient has not bottomed out and patient comfort is achieved. 9. If the patient feels that the bed is too soft/hard, press the Soft or Firm button to adjust the comfort settings. 10. Use a regular pillow to help support and stabilize the patient's head. Part No 1148139 27 Invacare® MA90Z Series Mattresses 4 OPERATION 4.9 Transferring Patient From/To a Gurney WARNING . ALWAYS engage the wheel locks of the bed and the wheel locks of the gurney before transferring the patient between the bed and the g...

Dieses Handbuch ist für folgende Modelle:
Camping - MA90Z (2.22 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien