Login:
Stimmen - 5, Durchschnittliche Bewertung: 3.4 ( )

Anleitung Blue Rhino, modell OUTDOOR LP GAS LANTERN GLL905W

Hersteller: Blue Rhino
Dateigröße: 933.57 kb
Dateiname: GLL905W-OM-104_EFS.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Use of base: Always use your lantern on a hard, non-combustable, level surface. An asphalt or blacktop surface may not be acceptable for this purpose. Do not use directly on wooden decks and wooden picnic tables. Keep all electrical cords away from a hot lantern. Do not use lantern for indoor heating. TOXIC fumes can accumulate and cause asphyxiation. After a period of storage and/or nonuse, check for leaks, and burner obstructions. If lantern is not in use, the tank must be disconnected and stored in a proper location. Do not store a spare LP gas tank under or near this appliance. Use protective gloves when assembling this product. Do not force parts together as this can result in personal injury or damage to the product. Do not operate lantern with a hole or crack in the mantle. Do not attempt to operate the lantern without a mantle installed. Deaths, serious injury or damage to property may occur if the above is not followed exactly. Operating Instructions Lantern is inteded to hang from the chain on a noncombustable, sturdy support, unless lantern is used with optional base (part number 55-09-287, not included). This lantern is designed to operate with a one pound 7-3/8” high disposable / 16.4 oz. propane gas tank (DOT 39 Cylinder). DO NOT ATTEMPT TO REFILL ANY ONE POUND (16.4 oz.) PROPANE GAS TANKS! Connecting Gas Tank 1. Make sure the control knob is in the “OFF” position. (Figure 1) 2. Lubricate the threads of the regulator valve with petroleum jelly, insert the gas tank into the regulator valve and hand-tighten firmly. (Figure 2) 3. Insert LP gas tank into the base. 4. Test for leaks Checking for Leaks WARNING: Failure to inspect this connection or follow these instructions could cause a fire or an explosion which can cause death, serious bodily injury, or damage to property. 1. Make 2-3 oz. of leak solution by mixing one part liquid dishwashing soap with three parts water. 2. Make sure control knob is “OFF”. 3. Attach LP gas tank, per “Connecting Gas Tank” instructions. 4. Spoon several drops of solution, or use squirt bottle, at the LP gas tank to regulator connection. 5. Inspect the solution at the connections, looking for bubbles or the smell of rotten cabbage. a. If NO bubbles appear or smells of rotten cabbage, the connections are secure. b. If bubbles appear, you have a leak. 1. Loosen and retighten this connection, making sure the connection is secure. 2. Retest with solution. If you continue to see bubbles after several attempts, disconnect propane source and contact 1.800.762.1142 for assistance. Lighting DO NOT expose the lantern to flammable vapors or liquids during lighting. 1. Make sure all labels, packaging and protective films have been removed from the lantern. 2. Make sure there are no obstructions of airflow to the gas unit. Spiders and insects can nest within and clog the burner / venturi tube at the orifice. A clogged burner tube can lead to a fire. 3. Control knobs must be in the “OFF” position. (Figure 1) 4. Attach the LP gas tank per the “Connecting Gas Tank” instructions. 5. Igniter: Turn the control knob counterclockwise to “ON” and repeatedly push the igniter button to ignite the mantle. Match: Wearing heat reistant gloves, position the lit long match or lit long butane lighter evenly next to the mantle. (Figure 3) a. Turn control knob counterclockwise to “ON”. b. Hold lit long match or lit long butane lighter next to mantle for up to 5 seconds. c. Remove long match/long butane lighter. d. Replace cap. Note: Once the mantle has been burned, it is very fragile. Be careful not to touch it with finger or match. 6. If ignition does not occur in 5 seconds, turn burner control knob “OFF”, wait 5 minutes and repeat lighting procedure. Caution: If burner flame goes out during operation, immediately turn the gas “OFF” and let the gas clear for about 5 minutes before re-lighting. Turning Off 1. Turn control knobs to the “OFF” position. 2. Allow lantern to completely cool. 3. Remove LP gas tank and properly store tank. Transporting While Lantern is ON 1. Carefully carry the lantern by the chain. 2. Do not touch any of the lantern surfaces as they may be hot 3. Before setting the lantern down, make sure the lantern is hanging from a sturdy, non-combustable support or the tank is properly in the base. While Lantern is OFF 1. The LP gas tank must be removed and stored properly. 2. Once the lantern is cooled, place the lantern (and optional base) in a plastic bag and secure the bag with a string. DO NOT COMPLETELY SEAL THE PLASTIC BAG. Note: The plastic bag will help protect from insects. Replacing Mantle 1. Turn control knob to “OFF” and remove LP gas tank. 2. Allow lantern to cool completely. 3. Open cap and remove globe 4. Attach mantle Note: Tie the mantles around grooves in burner. Note: Evenly distribute folds on mantle. Cut off the extra string. 5. Insert globe and close cap 6. Perform leak check Cleaning and Care CAUTION: All cleaning and maintenance should be done when lantern i...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien