Login:
Stimmen - 2, Durchschnittliche Bewertung: 3.5 ( )

Anleitung Precor, modell C936i

Hersteller: Precor
Dateigröße: 1.5 mb
Dateiname: c0163446-4f45-4528-903e-e3ce4f3eaba6.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Refer to Diagram 6. Align the upright support with the base assembly mounting bracket and secure it by following steps 7a and 7b. page 15 C O M M E R C I A L P R O D U C T S D I V I S I O N Important: With the handrails attached, the width of the treadmill is 33. inches (85 cm). It will not fit through a standard 32-inch doorway. 10. Prepare the unit for handrail installation. Diagram 9. For an easier installation, raise the incline to its maximum height by taking the following steps: a. Plug the treadmill into a power outlet and turn the unit ON. b. Stand to the side of the treadmill and press QUICKSTART (see inset). After a few seconds, the running belt begins moving. c. Press the INCLINE ^ key until the display shows an incline of 15 percent. d. Once the lift stops moving and the display indicates 15 percent, press the Stop (red) button and turn power switch OFF. 11. Remove the lower handrail clamp. Diagram 10. To prepare the unit for handrail installation, remove the four fasteners securing the lower handrail clamp. Use the hex key provided. Diagram 10 Remove the lower handrail clamp. Loosen and remove the four handrail clamp screws. Lower handrail clamp Diagram 9 Raise the incline. Incline lift Side rail QUICKSTARTTM key TIME DISTANCE CALORIES INCLINE PROFILE CALORIES/MINUTE METS SPEED page 16 C O M M E R C I A L P R O D U C T S D I V I S I O N 12. Attach handrails to the side and base brackets. Diagram 11. Important: Attach one handrail at a time. Take the following steps on one side of the treadmill and then, attach the opposite handrail. a. Slide the end of the handrail toward the handrail clamp. Ask your assistant to hold the handrail in place while you insert screw (C) with washer (F). Finger tighten the screw to secure the handrail to the side bracket. See Diagram 11, #1 and #2. b. Attach the lower portion of the handrail. Diagram 11, #3. Align the handrail bracket with the two base mounting holes in the side rail. Place a washer (D) onto each of two screws (C) and insert the screws. Finger tighten. c. Perform steps a. and b. on the opposite side. Diagram 11 Secure the handrails. Side bracket .-inch screw (C) with washer (F) 2 Lower portion of handrail 3 .-inch screws (C) with washers (D) Slide handrail into position. Handrail clamp 1 page 17 C O M M E R C I A L P R O D U C T S D I V I S I O N 13. Connect the heart rate cables. Diagram 12. Cables protrude from the ends of both handrails and connect the metal strips on the handrails to the receiver inside the display. Once the cables are properly connected, a user’s heart rate appears when the user grasps both touch-sensitive grips. Important: Attach one cable at a time. The cable receptacles mirror the connectors so that they cannot be improperly installed. Do not force a connection! Take time to look for the appropriate cable receptacle. Perform the following steps, one cable connection at a time. a. Slide the end of the cable into its receptacle. Diagram 12, #1. b. Place the excess cable inside the display opening. Diagram 12, #2. c. Move to the opposite handrail and complete steps a and b. 14. Test the heart rate feature. Diagram 13. a. Turn the unit ON. The Precor banner should appear in the display. b. Face the display and straddle the running belt. Diagram 12 Connect the heart rate cables. Display console Heart rate cable connections (male connector, female receptacle and vice versa for the opposite cable) Security clip Left handrail 1 2 Diagram 13 Test the heart rate feature. Heart rate grips Display console Heart rate blinking indicator IME NCE RIES LINE PROFILE CALORIES/MINUTE METS SPEED Hr page 18 C O M M E R C I A L P R O D U C T S D I V I S I O N c. Place your left hand on the left handrail’s heart rate grip and place your right hand on the right handrail grip. The letters “Hr” begin to blink in the upper right display indicating that a signal is being transmitted. Within about 15 seconds a heart rate appears. Note: If the blinking “Hr” does not appear, turn the unit OFF. Recheck the cable connections and ask someone else to try the test (steps a through c). d. When the test is satisfactorily completed, turn OFF the treadmill and continue with the assembly. 15. Replace the lower handrail clamp. Diagram 14. Replace the lower handrail clamp and the four fasteners removed in step 11. Make sure the top of the handrail is aligned with the top portion of the clamp. Turn all four fasteners until they are finger tight. 16. Secure the handrails. Diagram 14. Place a large washer (F) onto each of two screws (E). Thread the screws through the lower handrail clamp and finger tighten. Diagram 14 Install handrail clamp fasteners. Lower handrail clamp Washer (F) 1.-inch screw (E) Hand held heart rate grip Replace the four fasteners removed in step 11. page 19 C O M M E R C I A L P R O D U C T S D I V I S I O N 17. Tighten all mounting screws with the hex key (H) provided. Diagram 15. Start at the front of the treadmill with the four screws that attac...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien