Login:
Stimmen - 2, Durchschnittliche Bewertung: 3 ( )

Anleitung Toshiba, modell MA-68 SERIES

Hersteller: Toshiba
Dateigröße: 610.3 kb
Dateiname: 62c6966c-51e9-4a7d-b8f3-104ba731b6b2.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


It indicates nothing on the first item entry, showing 2, 3, 4, etc. from the second repeated item entry on. Since it has only one digit, 0 will be displayed for count 10, 1 for 11, etc. When an item-correct is operated by the 1 VOID I key, the count is decremented by 1. The negative symbol will be displayed during Percent Discount, Returned Merchandise operations, or when the sale total is negative. Displays 1 or 2 as code of the department through which the item has been entered. It also displays the change symbol "I_ " when the change amount is displayed_ in the AMOUNT portion, and displays the error symbol "" when an error arises. The current time is automatically displayed in the AMOUNT DISPLAY when the Control Lock is turned to the "LOCK” position. The time is indicated in the 24-hour system. TIME PISPLAY F0RMAT_ ex.) 8:05 a.m. j-J — j j t ~ _ -! U 1:24p.m. / J l__ I (13:24 ) RPT (1 digit): DPT (1 digit): TIME DISPLAY - 3 - KEYBOARD LAYOUT MA-68 KEYBOARD LAYOUT FEED NS # %- RTN MDSE X VOID C 7 8 9 A 5 6 1 2 3 0 00 TXBL 1 NON TXBL 2 R/A PO ST Chg TXBL TL AT/ /TL . t Department Keys FUNCTION OF EACH KEY PAPER FEED KEY This key is used to feed the paper. As Long as this key is pressed down, the paper keeps on feeding. This key will function at any position of the Control Lock except at "LOCK". NS NO-SALE KEY This key is used to open the cash drawer without relating to a sale. Thus it may be operated in such occasions as exchanging a bill into smaller changes and testing the print condition. To operate, depress this key with the Control Lock in the "REG” position in an out-of-sale condition. An "NSM symbol is printed to indicate "no-sale" and the drawer opens. QUANTITY EXTENSION (MULTIPLICATION) KEY This key is used to multiply a department entry by a quantity. The multiplication order is as follows: | QUANTITY | -* [_Xj - | UNIT PRICE] - 1 DEPT | max. 3 dig. max. designated The product by the Listing must not Capacity exceed 6 digits. - 4 - 7o- RTN MDSE VOID NON-ADD NUMBER PRINT KEY This key is used to print a non-add number, such as Customer No., and Check No., for future reference. A maximum 6-digit number may be entered and printed through this key, and the number will not affect any sales totals. To operate, enter the required No., and depress this key when the Control Lock is in the MREG" position. A non-add number entry is allowed as the first line item, between two line items, or after the sub-total amount if before finalizing the sale. PERCENT DISCOUNT KEY This key is used to enter a discount calculated on a percentage rate. When this key is depressed after a department item, the discount amount is calculated on the preset or a manual-entry rate and subtracted from the department item amount. This key can also be operated in the same way after depressing the 1 ST | key if the percent discounting is performed for the sale total. A percent rate can be preset on this key; however, if another rate is entered through the numeric keyboard prior to the depression of the \70-| key, the entered rate prevails. The preset rate will be active by a simple depression of the |~% -1 key. The fraction resulted from the percent calculation will automatically be rounded of f . Since the | %-1 key is fixed with non-taxable status, percent discount is calculated from the amount before taxed, and the tax added to the taxable items entered through |DP 1| (Taxable Department) will remain unchanged. RETURNED MERCHANDISE / DESIGNATED LINE VOID KEY This key is used to enter an item once purchased but returned by a customer, or to void an item recorded before the last line item within a sale. To operate, depress this key before or after the amount entry and then depress the Department Key to which the item belongs. ITEM CORRECT (LAST LINE VOID) KEY This key is used to delete the last line item of a Department or %- within a sale. Depressing this key once will remove the last line item from the bill, printing the same amount with the "VD" symbol below the item to the corrected. - 5 - CLEAR KEY This key is used to correct a numeric entry error if prior to depressing any other function key, or to correct any error condition and cancel the alarm buzzer. If this key is depressed before depressing a department key in a quantity extension sequence, all of the quantity, the [x] key, and' the unit price entries are cleared at a time. If this key is depressed after the 1RTN MDSE I and a numeric entry (or the reverse sequence), both the ] RTN MDSEj key and the numeric entries are cleared at a time. If the [c] key is depressed after a sub-total is obtained, the sub-total amount isthendisplayed. The [C] key may be operated regardless of any control Lock position except "LOCK". I? 8 9| 1* 5 6| U 2 3| 1 o oo| NUMERIC KEYS These keys are used to enter numeric values such as amount, quantity, and non-add number. Depressing the 1001 key once is the same as ...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien