Login:
Stimmen - 5, Durchschnittliche Bewertung: 3.6 ( )

Anleitung Omron Healthcare, modell HEM-412C

Hersteller: Omron Healthcare
Dateigröße: 634.38 kb
Dateiname: 10301722-fc7e-4f6e-8f5f-b92d0f1fba04.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Determine where your pulse is strongest. 2. The cuff should be assembled correctly when it is removed from the box. If it is not, pass the end of the cuff furthest from the tubing through the metal D-ring to form a loop. The smooth cloth should be on the inside of the cuff loop. 3. If the cuff is assembled correctly, the sewn hook material will be on the outside of the cuff loop and the metal D-ring will not touch your skin. 4. Put your left arm through the cuff loop. The bottom of the cuff should be approximately 1/2 inch above the elbow. The cuff tab should lie over the brachial artery on the inside of the arm. 7 HOW TO APPLY THE ARM CUFF HOW TO APPLY THE ARM CUFF 5. Pull the cuff so that the top and bottom edges are tightened evenly around your arm. 6. When the cuff is positioned correctly, press the sewn hook material FIRMLY against the pile side of the cuff. 7. Make certain the cuff fits snugly around your arm. The cuff should make good contact with your skin. 8. Sit in a chair with your feet flat on the floor and place your arm on a table so that the cuff is at the same level as your heart. 9. Relax your arm and turn your palm upward. 10. Be sure there are no kinks in the air tubing. 8 HOW TO TAKE A READING HOW TO TAKE A READING Please read “How To Apply The Arm Cuff” before taking a reading. 1. Press the On/Off button. SYSTOLIC mm Hg DIASTOLIC mm Hg Initial LCD Test a) All display symbols appear for about one second. This is the initial LCD Test. PULSE/MIN b) The display symbols Deflation Indication disappear and the Deflation Indication Symbol ( . ) starts to flash. c) When the monitor completes the necessary preparations Ready To Measure before measurement, the Ready To Measure Symbol ( ) appears next to a zero. NOTE: Wait for the Ready To Measure Symbol ( ) before taking a measurement. 2. Begin inflating the cuff by rapidly squeezing the inflation bulb until you have reached approximately 40 mmHg higher than your normal systolic reading. If your normal systolic blood pressure is unknown, inflate the cuff to 180 mmHg. 9 HOW TO TAKE A READING HOW TO TAKE A READING 3. Stop pumping the inflation bulb when you have reached your correct inflation level and remain still. The cuff will Indicated Value begin to deflate automatically. Drops . Measuring 4. As the cuff deflates, decreasing numbers appear on the display. The Ready To Measure Symbol ( ) flashes at the onset of oscillation signals. Blood Pressure Reading Display . . Pulse Reading Display (for approx. 2 sec.) 5. When measurement is complete, (for approx. 3.5 sec.) the Ready To Measure Symbol ( ) stops flashing and your blood pressure and pulse display alternately. 6. When the Deflation Indication Symbol ( . ) appears on the display, push the air release button to release any air left in the cuff. NOTE: Wait 5-10 minutes before taking another blood pressure measurement. Waiting allows the engorged blood vessels to return to normal. You may require more rest time between readings depending on your individual physical characteristics. REMEMBER TO KEEP A RECORD OF YOUR BLOOD PRESSURE AND PULSE MEASUREMENTS. 10 CARE AND MAINTENANCE CARE AND MAINTENANCE To protect your monitor from damage, please do the following: • Do not subject your monitor to extreme temperatures, humidity, and direct sunlight. • Do not fold the cuff and tubing tightly. • Do not inflate the monitor over 280 mmHg. • Do not disassemble the monitor. • Do not subject the monitor to strong shocks (for example, dropping the monitor on the floor). • Do not clean the monitor with volatile liquids. THE MONITOR SHOULD BE CLEANED WITH A SOFT, DRY CLOTH. 11 ERROR INDICATORS ERROR INDICATORS Error Symbol Cause Correction Cuff under-inflated. Wait 10 minutes before taking another measurement. Repeat steps listed under “How To Tke a Reading”, but manually inflate the cuff 40 mmHg higher than the previous inflation value. Movement during measurement. No pulse or blood pressure reading due to very weak artery pulse. Residual air pressure in cuff. Carefully read and repeat steps linsted under “How to Take a Reading.” Cuff over-inflated (more than 300 mmHg.) Batteries have run down. Replace all 4 four “AAA” batteries. If you continue to have difficulty obtaining a reading, call OMRON HEALTHCARE CUSTOMER SERVICE TOLL FREE 1-800-634-4350. Please tell the representative you have a Omron Model HEM-412C Manual Inflation Blood Pressure Monitor. 12 CAUTION INDICATORS CAUTION INDICATORS NOTE: POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. The product generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is n...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien