|
Anleitung Zusammenfassung
Diastolic Pressure Pulse Rate Measurement Error: Measure again. Wrap the cuff correctly and keep arm steady during measurement. Air Circuit Abnormality: Check cuff connection. Measure again. Pressure Exceeding 300 mmHg: Turn the unit off to clear, then measure again. Error Determining Measurement Data: Measure again. 9 10 INSTALLING BATTERIES 1. Press down on latch and lift the battery cover to open the battery compartment. 2. Install or replace 4 “AA” sized batteries in the battery compartment according to the indications inside the compartment. 3. Close the battery cover by pushing in the top end of the battery door. Replace the batteries if: Battery Cover 1. The weak battery symbol appears on the display. 2. Nothing appears on the display when the power is switched on. As the supplied batteries are for test only, they may be discharged earlier than batteries you buy in stores. Replace the batteries in pairs. Use only 1.5V AA alkaline batteries. Remove batteries when unit is not in use for extended periods of time. Date and time will need to be reset if batteries are removed or replaced. Note: Batteries are hazardous waste. Do not dispose of them together with the household garbage. 11 USING THE AC ADAPTER (NOT INCLUDED) This monitor is designed for operation with batteries or an optional AC adapter. Please use only a compatible, UL approved AC adapter with required voltage and current as indicated in this manual. Contact HoMedics Consumer Relations at 1-800-466-3342 to purchase a compatible AC adapter. Note: • Please unload the batteries when operating with the AC adapter for an extended period of time. Leaving the batteries in the compartment for a long time may cause leakage, which may lead to damage of the unit. • No batteries are needed when operating with the AC adapter. • Date and time will need to be reset if AC adapter is unplugged. 1. Connect the AC adapter with the AC adapter jack in the back of the unit as shown below. 2. Please use only the AC adapter included with this monitor. AC Adapter Input: 100-240V~0.2A 50/60Hz Output: 6V DC 500mA 3 W Max Connect AC adapter here 12 DATE & TIME SET PROCEDURE 1. To adjust the date/time, press the Set button . 2. The display will show a blinking number showing the month. Change the month by pressing the button. Each press will increase the number by one Set buttonin a cycling manner. Press the again to confirm the entry, and the screen will show a blinking number representing the day of the month. 3. Change the date and time as described in Step 2 above, using the button to change the numbers and the Set button to confirm the entries. Press the button blinking month increasing month confirm the entry repeat process to set date and time USING THE ARM CUFF Very Important: Proper cuff size is critical to accurate measurement. This monitor comes with two sizes of arm cuffs: Standard Size Fits 9"–13" (23 cm – 33 cm) Large Size Fits 13"–17" (33 cm – 43 cm) The appropriate cuff is suitable for your use if the colored arrow falls within the solid color line as shown below. Colored Arrow ARROW MUST FALL WITHIN YELLOW BAND ARROW MUST FALLWITHIN YELLOW BAND 9.5±14.2 Inches 24±36 CentimetersStandardSize Cu Fits: Center tube overmiddle of armMODEL# PP-BPCUFF5 Position cuff edge 0.6.–1.0. (1.5–2.5cm) above elbow. Center tube over middle of arm. Fit cuff securely. Allow room for two fingers to fit between the cuff and your arm. Solid Colored Line 14 13 1. If the cuff is not assembled, pass the end of the cuff furthest away from the tubing through the metal D-ring in order to form a loop. The smooth side without the felt material should be on the inside of the cuff loop. End of cuff D-ring ARROW MUST FALL WITHIN YELLOW BAND 2. Plug the cuff tube into the left side of the unit. 2~3 cm(0.8”~1.2”) Position cuff edge0.8–1.2 inches (2–3cm) above elbow. Fit cuff securely. Allow room for to fit between and your arm. Center tube overmiddle of Insert plug here 15 3. Open the arm cuff so that your arm may be placed through it. 4. Remove tight fitting clothing from around your upper left arm. 5. Position cuff edge 0.8-1.2 inches (2-3cm) above elbow. 6. Center tube over middle of arm. 7. Pull the end of the cuff so that it tightens evenly around your arm. Press the hook and loop material together to secure. Allow room for 2 fingers to fit between the cuff and your arm. 8. Lay your arm on a table (palm upward) so the cuff is at the same height as your heart. Make sure the tube is not kinked. 16 Note: If it is not possible to fit the cuff to your left arm, it can also be placed on your right arm. However, all measurements should be made using the same arm. To use on the right arm, you must position the artery symbol “ ” over the main artery. Locate the main artery by pressing with two fingers approximately 1" (2 cm) above the bend of your elbow on the inside of your right arm. Identify where the pulse can be felt the strongest. This is your main artery. Main Artery MEASUREMENT PROCED...
Dieses Handbuch ist für folgende Modelle:Herzfrequenzmesser - IB-BPA060A (1.34 mb)
Herzfrequenzmesser - PP-BPCUFF5 (1.34 mb)