TO SET TIME AND DAY Press on DAY, HOUR and MIN buttons to adjust time and day. TO RECORD THE (COMFORT) SETPOINT TEMPERATURE Select chosen setpoint temperature by using or button. Press on button (2 to 3 seconds) until icon appears on display. TO RECORD THE (ECONOMY) SETPOINT TEMPERATURE Select chosen setpoint temperature by using or button. Press on button (2 to 3 seconds) until icon appears on display . TO RECORD THE (VACATION) SETPOINT TEMPERATURE To program the Vacation temperature, select th

heruntergeladen wurde: 1   Dateigröße: 915 kb   Hersteller: Aube Technologies  
Kategorie: Steuerungen & Regelgeräte
@name

The factory settings are indicated by the gray cells in the following table. SW1 Early Start a Off On SW2 Temperature / time format b °C / 24-hour °F / 12-hour SW3 Cycle length c 15 seconds 15 minutes SW4 Not used -- a. Early Start can be used in Automatic mode only. When this function is enabled, the thermostat calculates the optimal time to start heating in order to obtain the desired temperature by the set time. The thermostat re-assesses the start time daily based on the previous day’s perfo

heruntergeladen wurde: 1   Dateigröße: 308 kb   Hersteller: Aube Technologies  
Kategorie: Steuerungen & Regelgeräte
@name

STEP 6: program program hold /return SA PM TEMP 2 MT WTHF AM 1 HEAT MT WTHF AM 1 HEAT MT WTHF AM 1 HEAT ¦ Press again to move to the next program number. ¦ Repeat Steps 3 through 5 to change the remaining Weekday, Saturday, and Sunday programs. (There are a total of 12 programs.) ¦ After cycling through all 12 programs, press again to return the display to normal. ¦ Press at any time to exit the Program Mode. ® Reviewing Programs To review your program settings, press program repeatedly to cycle

heruntergeladen wurde: 0   Dateigröße: 456 kb   Hersteller: Aube Technologies  
Kategorie: Steuerungen & Regelgeräte
@name

NOTE: Do not connect a “Common” wire this thermostat. Tape up the wire and do not use. Mount Snap open the your thermostat the release tab on the the thermostat. Position wallplate on through large opening. Then level appearance. Mark holes if existing holes Hunter Thermostat holes. Drill holes with 3/16" bit and gently Reposition wallplate to wall, pulling through large opening. Insert mounting screws provided into wall anchor and tighten. 2.) FIGURE 2 14-15Installation Selector Switches The he

heruntergeladen wurde: 11   Dateigröße: 590 kb   Hersteller: Aube Technologies  
Kategorie: Steuerungen & Regelgeräte
@name

TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician. This thermostat is designed to be used with a self-protected heating system equipped with linear limit control and circuit breaker. .. For a new installation, choose a location about 5 ft. (1.5 m) above the floor, facing the heating system and on an inside wall. .. Avoid locations where there are air drafts (top of staircase, air outlet), dead air spots (b

heruntergeladen wurde: 0   Dateigröße: 352 kb   Hersteller: Aube Technologies  
Kategorie: Steuerungen & Regelgeräte
@name

“HE” position is for certain electric systems having a fan relay. n Furnace or Heat Pump selector (NORMAL – O – B switch) The factory position for this switch is in the NORMAL position. Leave it in this position if you have ANY system that uses gas, oil, electric, or hot water heating. If you have a single-stage Heat Pump (no emergency heat source), then slide the switch to the position that matches your Reversing Valve type. If your heat pump system has a “B” wire, slide the switch to “B” for y

heruntergeladen wurde: 0   Dateigröße: 229 kb   Hersteller: Aube Technologies  
Kategorie: Steuerungen & Regelgeräte
@name

Day Program 1 Program 2 Program 3 Program 4 Monday – Friday Time Temp Time Temp Time Temp Time Temp Saturday – Sunday Time Temp Time Temp Time Temp Revising Programs PROGRAM PROGRAM To temporarily change the current set temperature without af Temporary Manual Override ON position. To run the Fan on continuously, slide the Fan switch to the and heat pump operation, the Fan will turn on with the system. be turned on by your furnace after its warm-up delay. For electric heat, air conditioning, on a

heruntergeladen wurde: 5   Dateigröße: 1 mb   Hersteller: Aube Technologies  
Kategorie: Steuerungen & Regelgeräte
@name

Verify that the wall plate is visually level and securely tighten both screws. 16 GRCRHY/0W/BRCGY1Y/0W/ BY1Terminal Shield GRCRHY/0W/BRCGY1Y/0W/ BY1Terminal Shield 17 inSTalling ThE ThErMoSTaT, ConT. ConnECTing ThE WirES 1. Loosen, but do not remove, the terminal screws. note: a jumper wire has been provided, connecting the rC and rh terminals for systems that do not provide both an rh and rC wire. if you have both an rh and rC wire, remove this jumper. if you do not have both an rh and rC wire,

heruntergeladen wurde: 29   Dateigröße: 9 mb   Hersteller: Aube Technologies  
Kategorie: Steuerungen & Regelgeräte
@name@name

Disconnect power before beginning installation. Must be installed by a certified electrician. Read these instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition. Need Help? For assistance with this product please visit or call Honeywell Customer Care toll-free at 1-800-831-2823. Installation Guide Installation Guide The equipment interface module (EIM) allows you to control a baseboard heater, a convector or a fan-forced heater in a 120-

heruntergeladen wurde: 1   Dateigröße: 924 kb   Hersteller: Aube Technologies  
Kategorie: Steuerungen & Regelgeräte
@name

1 Controls and display.............................................................................................. 2 Installation Installation guidelines............................................................................................ 3 Mounting the thermostat ....................................................................................... 4 Wiring .................................................................................................................... 5 Configurat