Login:
Stimmen - 4, Durchschnittliche Bewertung: 4.5 ( )

Anleitung Home Automation, modell 13R00-4

Hersteller: Home Automation
Dateigröße: 74.14 kb
Dateiname: f9a0c81e-9119-409d-8713-6ad2b3ad6350.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Under these conditions, the heat pump will run continuously and the auxiliary heat will cycle on and off as needed. If you wish to temporarily override Energy Efficient Control to heat as quickly as possible, press the Hold key. The RC-101 will use the Auxiliary Heat as needed to reach the heat setting, then resume Energy Efficient Control once the setting is reached. Remember to turn Hold off to resume programmed operation. 3 OPERATION To take advantage of all the benefits and features offered by your thermostat, we recommend that you start by becoming familiar with its operation. AUTO 4 ModeHold 2 Prog 3 Fan 5 1 DAY COOL : P 6 7 OMNISTAT 8 9 1- Display The Display is used to show current time, temperature, outdoor temperature (optional), mode, and to give useful information that will guide you through normal operation of your thermostat. 2- Hold Press the Hold key to set the system into Hold mode. In Hold mode, the thermostat will not change its settings by program. When hold mode is first turned on, the RC-101 will use the auxiliary heat to get to the heat setting as quickly as possible. Once the temperature is at or very near the heat setting, or if the temperature is already near the heat setting, the RC-101 will resume energy efficient operation. 4 3- Prog Press the Prog (programming) key to set the current time and day (hours, minutes, day of week), and to program the temperature time schedules for the MORN, DAY, EVE, and NITEperiods. 4- Mode Press the Mode key to set the thermostat mode to Off, Heat, Cool, Auto, or EM Heat. In Off mode, the heating and cooling systems are both off and do not respond to changes in temperature settings. In Heat mode, the heating system responds to maintain your desired heating setting. In Cool mode, the cooling system responds to maintain your desired cooling setting. In Auto mode, your thermostat will automatically switch between heat and cool to maintain your desired heating and cooling settings. In Emergency Heat mode (displayed as EM HEAT) the thermostat will turn off the heat pump and use the auxiliary heating to maintain the temperature setting. This mode should only be used if the heat pump is malfunctioning, because the auxiliary heat costs more to operate than the heat pump. 5- Fan Press the Fan key to set the system fan to Fan Auto or Fan On. In Fan Auto mode, the fan runs only when the system calls for heating or cooling. In Fan On mode, the fan runs continuously. 5 6- Down Arrow (U) Press the Down Arrow key to lower the desired temperature. 7- Up Arrow (U) Press the Up Arrow key to raise the desired temperature. 8- Aux Heat Indicator The Aux Heat indicator (green) glows when the auxiliary heat is on. 9- Check Indicator The Check indicator (red) may be used to indicate a malfunction of the heat pump, of for some other condition. Your installer will explain its use. Note: To check your desired setting without changing it, press the up or down arrow key (U or U) once. 6 DISPLAY The following icons will be displayed during normal operation: FAN AUTO 10 9 8 7 6 11 12 13 MORN DAY EVE NITE REMOTE HOLD EM HEAT OFF COOL 1 :: 2 OUTSIDE DESIRED A 4 5 3 1- Temperature Display Shows the current temperature, desired temperature, or heating and cooling settings. 2-Time Display Shows the current time of day. 3-DESIRED DESIRED is displayed when the temperature display shows the desired temperature setting. 4-OUTSIDE OUTSIDE will be displayed when the temperature display shows the outdoor temperature. The outdoor temperature will be displayed every 4 seconds. 7 5-. .. The Top . .. is displayed when the heating or cooling system is running. The Bottom . .. is displayed when the Auxiliary heat is on. 6-COOL COOLis displayed when the system is in Cool mode. 7-AUTO AUTOis displayed when in automatic changeover mode. 8-HEAT HEATis displayed when the system is in Heat mode. EM HEAT is displayed when the Emergency Heat is on. 9-FAN FANis displayed when the fan is set to run continuously. 10-OFF OFFis displayed when the system is in the Off mode. 11-REMOTE REMOTE is displayed when the last command received by the thermostat was sent by a remote system. 12- Period Indicators MORN, DAY, EVE, or NITE is displayed when scheduled temperature changes are made by the thermostat programs. 8 13-HOLD HOLD is displayed when the system is in Hold mode. FILTER REMINDER Your thermostat logs the amount of time your heating and cooling system has been running and gives you a reminder when it's time to replace your filter. " F I Lt " will be displayed every four seconds in the place of the time display when it is time to change you filter. To clear the reminder, press the Prog key. The display will return to normal in 10 seconds. Don't forget to change your filter! ANTICIPATION Your thermostat has a sophisticated control system designed to keep you comfortable while saving energy. Part of the control system is a feature called "anticipation", which anticipates the need to turn the system on or off ...

Dieses Handbuch ist für folgende Modelle:
Steuerungen & Regelgeräte - 13R00-4 (74.14 kb)
Steuerungen & Regelgeräte - 13R00-4 (74.14 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien