Anleitung Zusammenfassung


If the up arrow is pressed at 11:45 PM, or the down arrow is pressed at 12:00 AM, the time display will be blank, indicating that no scheduled temperature changes will be made for that period. Your thermostat will follow a set of time scheduled programs on weekdays (Monday-Friday), on Saturday, and on Sunday. This will allow you to have different heating and cooling settings on Saturday and Sunday, than you normally would have for weekdays (Monday Friday). When programming the time schedules, the weekday time schedule is programmed first. The Saturday time schedule is programmed second, and the Sunday time schedule is programmed last. 11 SETTING TIME SCHEDULES To view or change the programming time schedules of your thermostat, press and the Prog key four times. The weekday MORN time will flash. 1. Use the arrow keys (U-U) to change the scheduled time for the displayed period (MORN, DAY, EVE, or NITE). :: A MORN DESIRED 2. Press the Prog key to advance to the next item. 3. Use the arrow keys (U-U) to change the desired cool setting. MORN COOL DESIRED :: A 4. Press the Prog key to advance to the next item. 5. Use the arrow keys (U-U) to change the desired heat setting. MORN DESIRED :: A HEAT 6. Press the Prog key to advance to the next period. 12 Repeat steps 1-6 for the DAY, EVE, and NITE periods. Afterwards, repeat steps 1-6 for 4 daily periods on Saturdays (Day 6), and 4 daily periods on Sundays (Day 7). The temperature display will show "6" for Saturdays, and "7" for Sunday times. Note: If Programming Mode is not being used and Day/Night Mode is being used, only the Weekday -DAY and NITE settings can be programmed. DAY/NIGHT MODE Your thermostat can be configured to change its temperature settings from "DAY" to "NITE" when commanded from a remote location. If so, the thermostat will use the weekday "DAY" and the weekday "NITE"settings. "REMOTE" and either "DAY" or "NITE" will be displayed when a command is sent from a remote location. You can use the arrow keys (U-U) to override the temperature settings, or press the Hold key to prevent any future remote changes. Follow the procedure shown in Programming Mode, to change the programmed DAYand NITEsettings. PROGRAMMABLE ENERGY SAVER MODE (PESM) Your thermostat can be configured to allow a remote system to override it. The thermostat sends the temperature to the remote system. The remote system will use the temperature to determine whether or not to override the thermostat based on its own temperature settings. "REMOTE" will be displayed when the remote system has control of the thermostat. You cannot use the arrow keys (U-U) or any other key on the thermostat to override the remote system. To resume normal operation of your thermostat, you must turn the energy saver feature off at the remote system. 13 SYSTEM MODE Your thermostat can be connected to an automation system or personal computer. With network software, the remote system can send commands to the thermostat to change mode, cool setting, heat setting, status of fan and hold, and other items. "REMOTE" will be displayed when a command is sent from the automation system or personal computer. You can use the arrow keys (U-U) on the thermostat to change the temperature settings. When the temperature settings are changed at the thermostat, "REMOTE" will no longer be displayed. Press the Hold key to prevent thermostat programs or the remote system from changing temperature settings. "HOLD"will be displayed at the thermostat. AUTOMATIC TIME UPDATE The thermostat time will automatically be updated by the connected automation system. POWER OUTAGES The thermostat will restart the heating/cooling system 3 to 8 minutes after the electricity comes back on. All settings and programs are stored permanently, and will not be affected by a power outage. CLOCK The thermostat clock is maintained for approximately 25 minutes during an electrical outage. 14 TIME SCHEDULES The table below shows the time schedules that are currently set into your thermostat. There is a blank table at the bottom that can be used to plan changes to the current schedule. WEEKDAYS SATURDAYS SUNDAYS MORN 6:00 AM 8:00 AM 8:00 AM COOL 78 78 78 HEAT 70 70 70 DAY 8:00 AM COOL 85 85 85 HEAT 62 62 62 EVE 6:00 PM COOL 78 78 78 HEAT 70 70 70 NITE 10:00 PM 11:00 PM 10:00 PM COOL 82 82 82 HEAT 62 62 62 WEEKDAYS SATURDAYS SUNDAYS MORN COOL HEAT DAY COOL HEAT EVE COOL HEAT NITE COOL HEAT TWO YEAR LIMITED WARRANTY Home Automation, Inc. (HAI), warrants this product against defects in material and workmanship, under normal use and service, for a period of two (2) years from the date of purchase by the consumer. During the warranty period, HAI will repair or replace, at its option, any HAI thermostat that fails due to defect. This warranty does not cover the cost of removal or reinstallation of any thermostat. This warranty does not cover failure caused by damage to the thermostat while in your possession (other than damage caused by defect or malfunction), o...

Dieses Handbuch ist für folgende Modelle:
Steuerungen & Regelgeräte - RC-100 (68.79 kb)
Steuerungen & Regelgeräte - RC-100 (68.79 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien