Login:
Stimmen - 4, Durchschnittliche Bewertung: 3.5 ( )

Anleitung Elitegroup, modell TRW-1

Hersteller: Elitegroup
Dateigröße: 302.37 kb
Dateiname: 7c543bae-c831-40df-b2ea-4103789ea04d.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


The system can be operated thermostatically or manually from the transmitter. The system operates on radio frequencies (RF) within a 20'’range using non-directional signals. The system operates one of 1,048,576 security codes that are programmed into the transmitter at the factory; the remote receiver’s code must be matched to that of the transmitter prior to initial use. Review COMMUNICATION SAFETY SECTION under TRANSMITTER section and THERMO SAFETY SECTION under REMOTE RECEIVER section. These signal/temperature safety features shut down the fireplace system when a potentially unsafe condition exists. ROOM TEMP THERMO MODE “SET” ONSETOFFLCD DISPLAY ON/UPBUTTON OFF/DOWNBUTTON SET BUTTON ECS WALL MOUNT THERMOSTAT The wall/transmitter operates on (2) 3V Button Cell (Included) which powers the LCD screen and powers the RF signal. These batteries are made specifically for remote controls and electronic lighters. Before using the transmitter the 3V batteries must be installed into the battery compartments. It is recommended that CR2032 lithium batteries always be used for longer battery life and maximum operational performance. Upon initial use, there may be a delay of five seconds before the remote receiver will respond to the transmitter. This is part of the system’s design. If the LCD screen will not come on, check the 3V Button Cell battery. TO INSTALL BATTERIES IN THE WIRELESS THERMOSTAT 1. Remove face from backing plate This is done by sliding the face up about 1/2” then pull the face off the base plate. As shown in Figure #1 2. Locate the (2) holders for the 3V button cell batteries. 3. Slide the button cell batteries into the battery holders. (Make sure that the batteries are installed with the (+) plus side facing you or up. TO REMOVE THE BATTERIES IN THE WIRELESS THERMOSTAT 1. Remove face from backing plate This is done by sliding the face up about 1/2” then pull the face off the base plate. As shown in Figure #1 2. Locate the (2) holders for the 3V button cell batteries. 3. Insert a small screwdriver into the slot above the button cell battery and push the battery out. AS shown in Figure #2 Figure #1 Figure #2 ROOM TEMP ONOFFSETECS BACK OF UNIT (2) 3 Volt Button Cell Batteries Slots + Plus SidePlus + SideBattery Removal 05 Page 1 of 9 Part #17810 ROOM TEMP ROOM TEMP WALL MOUNTING THE THERMOSTAT 1. The wireless Thermostat must be located within 20’ of the receiver, This is the normal operational distance. 2. Remove face from backing plate as shown in Figure #1 then locate the (2) two holes that mount the plate to the wall. 3. After locating the (2) two mounting holes and mark the holes on the wall. 4. Use the (2) two dry wall anchors and screws ( that are supplied) to mount the base plate to the wall as shown. 5. Thermostat can also be mounted onto an existing (Plastic) electrical box. 6. Base plate should be mounted level on the wall for best operation. GENERAL INFORMATION WALL MOUNT THERMOSTAT OPERATION FUNCTIONS 1. ROOM TEMP – Current room temperature. 2. F – Degrees Fahrenheit (C Indicates degrees Celsius) 3. FLAME ICON – Indicates APPLIANCE IS ON. 4. SET- Indicates transmitter is in thermostat mode. 5. DASHES – Indicate thermostat mode is being disabled. When transmitter is not in the thermostat mode. The word (SET) will not appear. SET 1. This TS/R-2-A Wall/transmitter has ON, OFF, and SET functions that are activated by pressing the buttons on the face of the transmitter. ON OFF 2. Upon initial use, there may be a delay of five seconds before the remote receiver will respond to the transmitter. This is part of the system’s design. If the LCD will not come on, check the 3V-button cell battery. SETTING MANUAL OPERATION 1. When the ON button on the wall/transmitter is pressed a flame icon on the LCD screen wil appear when the appliance is ON. 2. When the appliance is OFF the flame icon will not appear. WALLROOM TEMP ONOFFSETECS ROOM TEMP 1 2 3 SET ROOM TEMPSET 5 4 SETTING THERMOSTAT OPERATION ROOM TEMPSET ROOM TEMPSET 1. If the transmitter is in the thermostat mode the word (SET) will appear on the LCD screen. 2. When the SET button is pressed the temperature digits will begin to flash. 3. While the temperature digits are flashing use the ON button to increase the set temperature or use the OFF button to decrease the set temperature to your desired temperature. 4. When the desired temperature setting is reached press the SET button, again and the word SET will appear on the LCD screen and now the transmitter will automatically send an ON or OFF signal to the receiver. 5. To disengage the thermostat mode push the OFF button or push and hold the SET button until (2) dashes appear on the LCD screen. When you release the SET button this will disengage the thermostat mode and the word SET will disappear from the LCD screen. 0 0 SETTING F / C SCALE 0 0 The factory setting for temperature is degrees Fahrenheit ( F ) . To change this setting to Centigrade (C ), you must press and hold both the ON and OFF b...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien