Anleitung Honeywell, modell CHRONOTERM IV T8624D
Hersteller: Honeywell Dateigröße: 302.84 kb Dateiname: f868c591-a58c-404c-af25-8441a773ff96.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
5 T8624D CHRONOTHERM® IV DELUXE ZONE MULTISTAGE THERMOSTAT T8624D CHRONOTHERM® IV DELUXE ZONE MULTISTAGE THERMOSTAT Select Installer Setup Number (Press Time ^ key to change) Factory-Setting Other Choices (Press ^ or Ў key to change) Actual SettingDisplay Description Display Description Not used 1 thru 4 — — — — — Heating cycle ratea 5 6 Stage 2 3 or 9 3—3 cph used for steam systems 6—6 cph factory setting for all stages of system 9—9 cph used for electric heat Not used 6 thru 11 — — — — — System setting adjustment 12 1 Manual changeover 0 or 2 0—Auto changeover 2—Fixed auto changeover Adaptive Intelligent Recovery™ control 13 0 Adaptive Intelligent Recovery™ control is activated (system starts early so setpoint is reached by start of program period) 1 Conventional recovery (system starts recovery at programmed time) Degree temperature display 14 0 Temperature is displayed in °F 1 Temperature is displayed in °C Not used 15 — — — — — Clock format 16 0 12-hour clock format 1 24-hour clock format Not used 17 and 18 — — — — — Extended fan operation in heating 19 0 No extended fan operation after the call for heat ends 1 Fan operation is extended 90 seconds after the call for heat ends. Extended fan operation in cooling 20 0 No extended fan operation after the call for cool ends 1 Fan operation is extended 90 seconds after the call for cool ends. Not used 21 thru 23 — — — — — Outdoor temperature display (models with OT terminals) 24 0 No outdoor temperature is displayed 1 Outdoor temperature is displayed. Needs a C7089B1000 Outdoor Sensor to operate. Not used 25 thru 32 — — — — — a The cycle rate for the second stage of heat is adjustable with 6 cph being the factory setting. (Continued) 69-1074 6 T8624D CHRONOTHERM® IV DELUXE ZONE MULTISTAGE THERMOSTAT T8624D CHRONOTHERM® IV DELUXE ZONE MULTISTAGE THERMOSTAT Select Installer Setup Number (Press Time ^ key to change) Factory-Setting Other Choices (Press ^ or Ў key to change) Actual SettingDisplay Description Display Description Minimum off time for the compressor 33 5 5 minute minimum off time for the compressor 0 thru 4 Minimum number of minutes (0 thru 5) the compressor will be off between calls for the compressor Temperature range stops in heating 34 90 Highest setpoint heating can be set to 40 to 89 Temperature range (1°F increments) heating setpoint can be set to Temperature range stops in cooling 35 45 Lowest setpoint cooling can be set to 46 to 99 Temperature range (1°F increments) cooling setpoint can be set to Not used 36 — — — — — Temperature display adjustment 37 0 No difference in displayed temperature and actual room temperature 1 thru 6 1—Display adjusts to 1°F higher than actual room temperature 2—Display adjusts to 2°F higher than actual room temperature 3—Display adjusts to 3°F higher than actual room temperature 4—Display adjusts to 1°F lower than actual room temperature 5—Display adjusts to 2°F lower than actual room temperature 6—Display adjusts to 3°F lower than actual room temperature IMPORTANT Press Day until the current day is displayed. Review the settings to confirm that they match the system. Press Run Program to exit the NOTE: Sun=Sunday, Mon=Monday, Installer Setup. The thermostat has saved the Tue=Tuesday, Wed=Wednesday, Installer Setup changes and initiated a reset in Thu=Thursday, Fri=Friday, Sat=Saturday. order to operate with the new settings. Be sure to set the current day and time immediately. Setting Current Day and Time Press Set Current Day/Time. NOTE: On initial power up or after an extended power loss, 1:00 pm flashes on the dispaly until a key is pressed. M10313 Set Program System Fan Set Current Day/Time Wake Leave Return Sleep Day Day Heat/Cool Settings Daylight Time PM Tue Set Day/Time M10312 Set Program System Fan Set Current Day/TimeSet Current Day/Time Wake Leave Return Sleep Day Heat/Cool Settings Daylight Time Mon PM Set Day/Time 69-1074 7 T8624D CHRONOTHERM® IV DELUXE ZONE MULTISTAGETHERMOSTAT . Press Time ^ ^^ or Time Ў ЎЎ until the current time is Table 4. Tests Available In The Installer Self-Test. displayed. NOTE: Tapping the Set Current Day/Time will advance the time in one hour increments. Time Test Number Self-Test Description 10-19 Heating equipment can be turned on and off 30-39 Cooling equipment can be turned on and off 40-49 Fan equipment can be turned on and off 60 0 to 60 19 Keyboard keys test 70-79 Thermostat information including date code and software versions are displayed Set Program System Fan Set Current Day/Time Wake Leave Return Sleep Day Heat/Cool Settings Daylight Time Set Day/Time AM Tue M10314 NOTE: If the current time is Daylight Savings Time, press Daylight Time until DST is displayed. Set Program System Fan Set Current Day/Time Wake Leave Return Sleep Day Heat/Cool Settings Daylight Time Daylight Time Set Day/Time AM Tue DST M10315 Press Run Program. Set Program System Fan Run Program Set Current Day/Time Wake Leave Return Sleep Day Heat/Cool Settings Daylight Time AM Room Tue Wake...