M10257A TEST NUMBER Fig. 11. Display of test number. Table 7. Tests Available in Installer System Test. Test Number System Test Description 10-19 Heating equipment can be turned on and off 30-39 Cooling equipment can be turned on and off 40-49 Fan equipment can be turned on and off 60 0 to 60 19 Keyboard keys test 70-79 Thermostat information including date code and software versions are displayed Refer to Table 8 for the directions and results of the specific tests. NOTE: Press Time ^ ^^ to advance to the next test and Time Ў ЎЎ to go to the previous test. Press Run Program to exit the system test. Table 8. Installer System Test Options. Key to Press Test Number Description Heating Equipment System Test Time ^ 10 Enter heating equipment system test. ^ 11 Heat comes on. When Installer Setup number 2 is 1, the system fan is also energized. Ў 10 Heat and system fan turn off. Cooling Equipment System Test Time ^ 30 Change from heating to cooling equipment system test. ^ 31 Cool and system fan come on. Ў 30 Cool and system fan turn off. Fan Equipment System Test Time ^ 40 Change from cooling to fan equipment system test. ^ 41 Fan comes on. Ў 40 Fan turns off. Key Operation System Test Time ^ 60 2 Change from fan to key operation system test. 68-0164—1 10 T8600D,T8601D ANDT8602D CHRONOTHERMT8600D,T8601D ANDT8602D CHRONOTHERMIV DELUXE PROGRAMMABLETHERMOSTATS NOTE: Press any key and the numbers will change on the PROGRAMMING display. Press Time Ў ЎЎ to scroll backwards and Time ^ ^^ to scroll forward. The Run Program, Key will not exit from this test. To exit, go to a different test and press Run Program. THERMOSTAT INFORMATION 1. Press the Time ^ ^^ key to access the thermostat information. M4934 2. Press the increase ^ key to display the production date code. The first two large digits are the month and the third digit is the last digit of the year (Example: 027=February 1997). M10351 3. Press the increase ^ key again to display the software identification code. (Example: 02 = software ID code 2) M4932A 4. Press the increase ^ key again to display the software revision number (Example: 001=Revision number 1). M10229 5. Press the increase ^ key again to display the EEPROM identification code. (Example: 314 = EEPROM ID 314) 6. Press the Run Program key to exit the system test. The M4933A system test times out after five minutes without any key presses. The keyboard is located behind the thermostat cover with three frequently used keys by the display. The thermostat display shows day, time, program period, temperature, system and fan operation selection. The thermostat can be set for four times and up to eight temperatures for each day of the week (28 independent time and 56 temperature settings). The ^ ^^ and Ў ЎЎ keys provide quick temporary temperature changes to increase comfort. The Hold Temp key provides energy efficient operation for extended periods of time. Before starting the programming procedure, use Table 9 to organize the program schedule. The factory preprogrammed time, temperature and fan settings are shown in brackets. If a daytime energy savings period is not used, press the period key (Leave or Return) until the time is blank. The fan setting feature is available on select thermostat models. Setting the Current Day and Time IMPORTANT Always press the keys with your fingertip or similar blunt tool.Sharp instruments like pens and pencil points can damage the keyboard. 1. Press Set Current Day/Time. NOTE: On initial power up or after an extended power loss, 1:00 pm flashes on the display until a key is pressed. Time Set Program System Fan Program Hold Temp Set Current Day/TimeSet Current Day/Time Wake Leave Return Sleep Day Heat/Cool Settings Daylight Time Copy Set Day/Time PM Mon M10312 2. Press Day until the current day is displayed. NOTE: Sun = Sunday, Mon = Monday, Tue = Tuesday, Wed = Wednesday, Thu = Thursday, Fri = Friday, Sat = Saturday. Time Set Program System Fan Program Hold Temp Set Current Day/Time Wake Leave Return Sleep DayDay Heat/Cool Settings Daylight Time Copy Set Day/Time PM Tue M10313 3. Press Time ^ ^^ or Time Ў ЎЎ until the current time is displayed. NOTE: Tapping the Set Current Day/Time will change the time in one hour increments. Time Time Set Program System Fan Program Hold Temp Set Current Day/Time Wake Leave Return Sleep Day Heat/Cool Settings Daylight Time Copy Set Day/Time AM Tue M10314 11 68-0164—1 T8600D, T8601D AND T8602D CHRONOTHERMT8600D, T8601D AND T8602D CHRONOTHERMIV DELUXE PROGRAMMABLE THERMOSTATS NOTE: If the current time is Daylight Savings Time, Programming the First Day press Daylight Time until DST is displayed. Start by programming the Wake time and temperature (and fan operation on select models) for any one day: AM DST Tue Set Day/Time 1. Press Wake. Time Set Program System Fan Program Hold Temp Set Current Day/Time Wake Leave Return Sleep DayWake Heat/Cool Settings Daylight Time Copy Set Program Start Time Setting AM Tue Heat M10315 Wake System Fan He...

Dieses Handbuch ist für folgende Modelle:
Steuerungen & Regelgeräte - CHRONOTHERM T8601D (863.9 kb)
Steuerungen & Regelgeräte - CHRONOTHERM T8602D (863.9 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien