Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.7 ( )

Anleitung Honeywell, modell Chronotherm IV T8601D

Hersteller: Honeywell
Dateigröße: 439.76 kb
Dateiname: 9704f011-38ce-472d-a9e0-529f60eae5e4.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


3 . 5 Factory-Setting Description . Conventional application where equipment control fan operation in heat mode . 6.6 cph used for conventional heat. . Manual changeover. Adaptive Intelligent Recovery. control is activated (system starts early so setpoint is reached by start of program period) Temperature is displayed in °F . 12-hour clock format . No extended fan operation after the call for heat ends No extended fan operation after the call for cool ends . No outdoor temperature is displayed . Heating and cooling setpoints can be set no closer than 3°F (1.5°C) . 5 minute minimum off- time for the compressor. Other Choices (Press ! or " key to change) Display Description . . 1 Heat pump or electric heat applications where thermostat controls fan operation in heat mode . . 1, 3 or 9 1.1 cph used for radiant floor heat, gravity system 3.3 cph used for hot water systems or high efficiency furnaces 9.9 cph used for electric heat systems . . 0 or 2 0.Auto changeover 2.Auto only 1 Conventional recovery (system starts recovery at programmed time) 1 Temperature is displayed in °C . . 1 24-hour clock format . . 1 Fan operation is extended 90 seconds after the call for heat ends 1 Fan operation is extended 90 seconds after the call for cool ends . . 1 Outdoor temperature is displayed. Needs a C7089B1000 Outdoor Sensor to operate . . 4 thru 10 Heating and cooling setpoints can be set no closer that chosen value: 4.4°F (2°C) 5.5°F (2.5°C) 6.6°F (3°C) 7.7°F (3.5°C) 8.8°F (4°C) 9.9°F (4.5°C) 10.10°F (5°C) . . 0 thru 4 Minimum number of minutes (0 thru 5) the compressor is off between calls for the compressor Actual Setting . . . . . . . . 69-1410.2 6 T8601D CHRONOTHERM® IV DELUXE PROGRAMMABLE THERMOSTATS T8601D CHRONOTHERM® IV DELUXE PROGRAMMABLE THERMOSTATS Select Installer Setup Number (Press Time ! key to change) Factory-Setting Other Choices (Press ! or " key to change) Actual Setting Display Description Display Description Temperature range stops in heating 34 90 Highest heating setpoint setting. 40 to 89 Temperature range (1°F increments) of heating setpoint settings. Temperature range stops in cooling 35 45 Lowest cooling setpoint setting. 46 to 99 Temperature range (1°F increments) of cooling setpoint settings. Not used 36 . . . . . Temperature 37 0 No difference in displayed 3 thru -3 1.Display adjusts to 1°F display temperature and actual higher than actual adjustment room temperature room temperature 2.Display adjusts to 2°F higher than actual room temperature 3.Display adjusts to 3°F higher than actual room temperature -1.Display adjusts to 1°F lower than actual room temperature -2.Display adjusts to 2°F lower than actual room temperature -3.Display adjusts to 3°F lower than actual room temperature Furnace air 43 2 30 days (System run time) 0, 1, 3, 4 0.off filter timer 1.10 days 3.60 days 4.120 days (Time is counted when heat, cool or fan is running) Humidifier pad monitor 44 0 Off 1, 2, 3 1.90 days 2.189 days 3.365 days Ultraviolet (UV) 45 0 Off 1 1.365 days air treatment (Time is counted by system lamp calendar days in any monitor mode.) IMPORTANT aNumber 2 must be set to 1 to extend fan operation. Review the settings to confirm that they match the system. Press Run Program to exit the Installer Setup. The thermostat has saved the Installer Setup changes and initiated a reset in order to operate using the new settings. Be sure to set the current day and time immediately. 7 69-1410.2 T8601D CHRONOTHERM® IV DELUXE PROGRAMMABLE THERMOSTATS T8601D CHRONOTHERM® IV DELUXE PROGRAMMABLE THERMOSTATS 4. Press Run Program. 1. Press Set Current Day/Time. NOTES: On initial power up or after an extended power loss, 1:00 pm flashes on the display until a key is pressed. M14619 Set Program System Fan Set Current Day/TimeSet Current Day/Time Wake Leave Return Sleep Day Heat/Cool Settings Daylight Time Set Day/Time Mon PM 2. Press Day until the current day is displayed. NOTES: Sun=Sunday, Mon=Monday, Tue=Tuesday, Wed=Wednesday, Thu=Thursday, Fri=Friday, Sat=Saturday. M14620 System Fan Set Current Day/Time Wake Leave Return Sleep Day Day Heat/Cool Settings Daylight Time Set Day/Time PM Tue 3. Press Time . or Time . until the current time is displayed. NOTES: Tapping the Set Current Day/Time changes the time in one-hour increments. Time M14621 System Fan Set Current Day/Time Wake Leave Return Sleep Day Heat/Cool Settings Daylight Time Set Day/Time AM Tue M14623 System Fan Run Program Set Current Day/Time Wake Leave Return Sleep Day Heat/Cool Settings Daylight Time Wake Room System Fan Heat Auto AM DST Tue Viewing or Resetting Timer Settings When the thermostat activates a timer, the thermostat flashes Filter until the timer resets. 1. Reset the timer by pressing the i key until the expired timer is displayed. M20244 3. Press the Run Program key. Filter Days M20243 2.Press the Time . key to reset the timer. Filter Days NOTES: If the current time is Daylight Savings Time, NOTE: You can view the number of days remaining at pres...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien