Anleitung Zusammenfassung


Can be programmed in hand (with batteries installed) or on wall to provide up to four temperature settings per day. Large digital clock (liquid crystal display) indicates continuous time, day, current period and room temperature. Adaptive Intelligent Recovery™ brings room temperature to programmed temperature at programmed time, maximizing comfort and energy savings. Temperature control program maintains temperature within 1° F of setpoint. Temporary program override available by using: — WARMER and COOLER keys. — SKIP next period key. — CHANGE to last period key. HOLD TEMP key provided for indefinite program override (vacation/holiday). Installer self-test and time delay override save installation time. SYSTEM light-emitting diode (LED) indicates system is energized. Models available with automatic or manual heat/ cool changeover. Batteries included provide power to maintain clock and memory during power failures. Switching subbase with wiring terminals included. Powered directly from control transformer, requiring an extra (24V) wire to thermostat. Fan operation switch to select either independent or direct thermostat control of fan in heating included on back of select models. CONTENTS Specifications ................................................. 2 Ordering Information ..................................... 2 Selection/Application ..................................... 4 Installation ..................................................... 5 Checkout....................................................... 11 Programming the Thermostat ...................... 14 Operating the Thermostat ............................ 18 Troubleshooting ........................................... 21 Glossary ....................................................... 22 C.H. • 9-93 • ©Honeywell Inc. 1993 • Form Number 68-0134 T8624C,D SPECIFICATIONS • ORDERING INFORMATION T8624C,D SPECIFICATIONS • ORDERING INFORMATION IMPORTANT: The specifications given in this publication do not include normal manufacturing tolerances. Therefore, this unit may not exactly match the listed specifications. Also, this product is tested under closely controlled conditions, and some minor differences in performance can be expected if those conditions are changed. TRADELINE® MODELS TRADELINE models (see Table 1) are selected and packaged to provide ease of stocking and handling and also maximum replacement value. LIGHT-EMITTING DIODE (LED): SYSTEM LED lights during thermostat ON cycle. VOLTAGE RATING: 15 to 30 Vac. CURRENT RATING: 1.6A maximum total per stage. OPERATING HUMIDITY RANGE: 5 to 90 percent relative humidity, noncondensing. OPERATING AMBIENT TEMPERATURE RANGE: 40° F to 110° F [4° C to 43° C]. SETPOINT RANGE: 45° F to 88° F [7° C to 31° C]. CALIBRATION: Self-calibrating thermostat and thermometer to ±1° F. SHIPPING TEMPERATURE: -20° F to +120° F [-29° C to +49° C]. CYCLES PER HOUR ADJUSTMENT: Heating: First stage of 2-stage heat models—fixed at 3 cph. Second stage of 2-stage heat models or heat stage of single-stage heat models—factory-set at 6 cph; field-adjustable to 1,3,6 or 9 cph. Cooling: Factory-set at 3 cph (not field adjustable); minimum off-time of five minutes. FINISH: Beige matte with decorative brushed metal faceplate or Premier White™. DIMENSIONS: Thermostat (mounted on subbase)—7 in. [178 mm] long, 5-5/16 in. [135 mm] high, 1-3/4 in. [44 mm] deep. See Fig. 1 for subbase dimensions. TYPICAL KEYPAD: See Fig. 2. ACCESSORIES: TG586A Locking Cover. TG512 Versaguard™ Universal Thermostat Guard. TABLE 1—TRADELINE MODELS. Thermostat Model Stages Changeover Switching ApplicationNumber Heat Cool Type System Fan T8624C 2 1 Auto HEAT-AUTO-COOL-OFF ON-AUTO Multistage T8624D 2 2 Auto HEAT-AUTO-COOL-OFF ON-AUTO Multistage T8624D 2 2 Manual HEAT-OFF-COOL ON-AUTO Multistage Ordering Information When purchasing replacement and modernization products from your TRADELINE® wholesaler or your distributor, refer to the TRADELINE Catalog or price sheets for complete ordering number, or specify— 1. Model number. 3. System, fan switching desired. 2. Number of heat and cool stages desired. 4. Application. If you have additional questions, need further information or would like to comment on our products or services, please write or phone: 1. Your local Honeywell Home and Building Control Sales Office (check white pages of your phone directory). 2. Home and Building Control Customer Satisfaction Honeywell Inc., 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386 (612) 951-1000 In Canada—Honeywell Limited/Honeywell Limitee, 740 Ellesmere Road, Scarborough, Ontario M1P 2V9. International Sales and Service offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. 2 T8624C,D T8624C,D Fig. 1—T8624 Subbase mounting dimensions in in. [mm]. 4 [121] 3 4 3 [83] 5 16 7 [179] 1 [46] 13 16 5 [135] 5 16 M5181A 4 3 32 [104] 1 31 32 [50] Fi...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien