Login:
Stimmen - 3, Durchschnittliche Bewertung: 5 ( )

Anleitung Bryant, modell TSTAT

Hersteller: Bryant
Dateigröße: 125.2 kb
Dateiname: b56d46de-06cb-4bcb-bd01-c7a0d27e98bb.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


11—Two-Speed Heat Pump ® Fig. 12—Two-Speed Heat Pump with Single-Stage Furnace with 2-Stage or Variable-Speed Furnace —Model 2S Thermostat —Model 2S Thermostat —9— MODEL 2S SINGLE-SPEED THERMOSTAT EASY SELECT HEAT PUMP TERMINAL BOARD MODEL 2S TYPICAL TWO-SPEED THERMOSTAT FAN COIL HEAT PUMP 24 VAC HOT FAN HEAT STAGE 3 COOL/HEATSTAGE 2 RVS COOLING COOL/HEATSTAGE 1 R G W/W1 Y/Y2 O/W2 Y1/W2 R G 24 VAC COMM N/A OUTDOOR SENSOR CONNECTION C B S1 S2 C Y2 C W2 R O Y1 W3 See notes 3, 7, 8, 9, and 11 W2 Y * E W3 A98497 24 VAC HOT FAN COOL/HEATSTAGE 1 HEAT STAGE 2 HEAT STAGE 3 RVS COOLING R G R G 24 VAC COMM N/A OUTDOOR SENSOR CONNECTION C B S1 S2 C C R J1 JUMPER REMOVE J2 JUMPER FOR HEAT STAGING See notes 3, 4, and 8 DH W/W1 Y/Y2 O/W2 Y1/W2 Y O W2 W1 Y/Y2 O W2 Y1 SUGGESTED DIP SWITCH SETTINGS ON A B C D OFF OFF OFF ON ON SUGGESTED DIP SWITCH SETTINGS A BCD OFF OFF OFF OFF A98496 ® Fig. 13—Two-Speed Heat Pump with Typical Fan Coil—Model 2S Thermostat MODEL AC SINGLE-SPEED THERMOSTAT EASY SELECT AIR CONDITIONER TERMINAL BOARD 24 VAC HOT HEAT STAGE 1 N/A FAN N/A COOL STAGE 1 R R 24 VAC COMM N/A OUTDOOR SENSOR CONNECTION C B S1 S2 C G G C J1 JUMPER J2 JUMPER See notes 1 and 8 DH Y1 O Y1/W2 Y/Y2 YY/Y2 O/W2 W/W1 W1 W2 SUGGESTED DIP SWITCH SETTINGS ON A B C D OFF OFF OFF OFF A98498 ® Fig. 15—Single-Speed Air Conditioner with Variable-Speed Fan Coil (FK, FV) —Model AC Thermostat ® Fig. 14—Single-Speed Heat Pump with Variable-Speed Fan Coil (FK, FV) and Special 3-Stage Electric Heat —Model 2S Thermostat MODEL HP SINGLE-SPEED THERMOSTAT EASY SELECT AIR CONDITIONER TERMINAL BOARD A98499 24 VAC HOT FAN HEAT STAGE 1 HEAT STAGE 2 COOL STAGE 1 N/A R G R G 24 VAC COMM N/A OUTDOOR SENSOR CONNECTION C B S1 S2 C C J1 JUMPER REMOVE J2 JUMPER FOR HEAT STAGING See notes 2 and 8 DH O Y1 Y/Y2 YY/Y2 O/W2 Y1/W2 W/W1 W1 W2 SUGGESTED DIP SWITCH SETTINGS ON A B C D OFF OFF ON OFF ® Fig. 16—Single-Speed Air Conditioner with Variable-Speed Fan Coil (FK, FV) —Model HP Thermostat —10— MODEL 2S TWO-SPEED THERMOSTAT EASY SELECT HEAT PUMP TERMINAL BLOCK MODEL 2S TWO-SPEED THERMOSTAT EASY SELECT AIR CONDITIONER TERMINAL BOARD 24 VAC HOT FAN COOL STAGE 1 COOL STAGE 2 HEAT STAGE 1 HEAT STAGE 2 R G R G 24 VAC COMM N/A OUTDOOR SENSOR CONNECTION C B S1 S2 C C R J1 JUMPER REMOVE J2 JUMPER FOR HEAT STAGING See notes 2 and 8 DH Y1Y1 W/W1 O/W2 Y1/W2 W1 Y/Y2 Y2Y/Y2 O W2 SUGGESTED DIP SWITCH SETTINGS ON A B C D OFF OFF ON OFF 24 VAC HOT FAN COOL/HEATSTAGE 1 RVS COOLING COOL/HEATSTAGE 2 HEAT STAGE 3 R R 24 VAC COMM N/A OUTDOOR SENSOR CONNECTION C B S1 S2 C G G C W2 W3 O Y1 R J1 JUMPER J2 JUMPER See notes 3, 8, 9, and 11 DH Y1 O Y1/W2 Y/Y2 Y2Y/Y2 O/W2 W/W1 W1 W2 SUGGESTED DIP SWITCH SETTINGS ON A B C D OFF OFF OFF OFF A98500 ® Fig. 17—Two-Speed Air Conditioner with Variable-Speed Fan Coil (FK, FV) R G 24 VAC COMM N/A OUTDOOR SENSOR CONNECTION B S1 S2 C ON A B C D 24 VAC HOT FAN HEAT STAGE 1 COOL STAGE 1 N/A N/A —Model 2S Thermostat MODEL AC SPLICE THERMOSTAT BOX RED GRN WHT YEL W/W1 Y/Y2 Y1/W2 O/W2 BRN See notes 1 and 11 SUGGESTED DIP SWITCH SETTINGS A98502 ® Fig. 19—Single-Speed Packaged Air Conditioner with Single-Stage Gas Furnace (588A, 589A) A98501 ® Fig. 18—Two-Speed Heat Pump with Variable-Speed Fan Coil (FK, FV) —Model 2S Thermostat MODEL AC SPLICE HEATER THERMOSTAT BOX CONTROL BOX N/A FAN HEAT STAGE 1 COOL STAGE 1 N/A 24 VAC HOT R G W/W1 Y/Y2 O/W2 GRN WHT BRN WHT BRN Y1/W2 RED YEL 24 VAC COMM N/A OUTDOOR SENSOR CONNECTION B S1 S2 C ON A B C D See notes 1, 11, and 12 SUGGESTED DIP SWITCH SETTINGS OFF OFF OFF OFF A98503 ® Fig. 20—Single-Speed Packaged Air Conditioner with Single-Stage Electric Heat (555A, 557A, 564A) —11— COOL STAGE 1 FAN HEAT STAGE 1 N/A HEAT STAGE 2 24 VAC HOT R G W/W1 Y1/W2 O/W2 Y/Y2 G W/W1 Y1/W2 O/W2 Y/Y2 MODEL HP SPLICE HEATER THERMOSTAT BOX CONTROL BOX YEL GRN WHT WHT RED (TRAN) PNK VIO RED RED 24 VAC COMM N/A OUTDOOR SENSOR CONNECTION B S1 S2 C ON A B C D BRN BRN See notes 2, 10, 11, and 12 SUGGESTED DIP SWITCH SETTINGS OFF OFF ON OFF A98504 ® Fig. 21—Single-Speed Packaged Air Conditioner with 2-Stage Electric Heat (555A, 557A, 564A) MODEL HP SPLICE HEATER THERMOSTAT BOX CONTROL BOX VIO HEAT STAGE 2 ORN RVS COOLING WHT N/A WHT COOL/HEAT YEL STAGE 1 GRN FAN RED 24 VAC HOT RED 24 VAC COMM N/A OUTDOOR SENSOR CONNECTION B S1 S2 C ON A B C D BRN BRN RED (TRAN) PNK R G Y/Y2 Y1/W2 O/W2 W/W1 See notes 3, 10, 11, and 12 SUGGESTED DIP SWITCH SETTINGS OFF OFF OFF OFF A98506 ® Fig. 23—Single-Speed Packaged Heat Pump with 2-Stage Electric Heat (665A, 657A, 664A) MODEL HP SPLICE HEATER THERMOSTAT BOX CONTROL BOX COOL/HEAT STAGE 1 RVS COOLING N/A HEAT STAGE 2 FAN 24 VAC HOT G R 24 VAC COMM N/A OUTDOOR SENSOR CONNECTION B S1 S2 C ON A B C D YEL ORN W/W1 Y/Y2 O/W2 Y1/W2 WHT WHT GRN RED BRN BRN See notes 3, 11, and 12 SUGGESTED DIP SWITCH SETTINGS OFF OFF OFF OFF A98505 ® Fig. 22—Single-Speed Packaged Heat Pump with Single Stage Electric Heat (655A, 657A, 664A) MODEL HP SPLICE THERMOSTAT BOX YEL STAGE 1 ORN COOL/HEAT RVS COOLING N/A HEAT STAGE 2 WHT GRN ...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien