Hersteller: Aube Technologies
Dateigröße: 274.82 kb
Dateiname: TH111-GFCI-NP-120.pdf

Unterrichtssprache:en

Das Dokument wird geladen, bitte warten
Das Dokument wird geladen, bitte warten

Anleitung Zusammenfassung


TO SET TEMPERATURE Press on or once to see setpoint temperature appear on display. Every subsequent press will change the setpoint temperature by one degree. (COMFORT) SETPOINT TEMPERATURE temperature by using or button. Press on TO RECORD THE Select chosen setpoint TO RECORD THE button (2 to 3 seconds) until icon appears on display. (ECONOMIC) SETPOINT TEMPERATURE Select chosen setpoint temperature by using or button. Press on button (2 to 3 seconds) until icon appears on display . TO RECORD THE To program the Vacation temperature, select the desired degree using the buttons and press on the and icon is displayed (app. 3 seconds). (VACATION) SETPOINT TEMPERATURE buttons simultaneously until the CHECKING GROUND FAULT CIRCUIT INTERRUPTER (GFCI) Adjust the setpoint temperature until heating indicator (flames) appears on display. Press TEST button. The test is conclusive if the warning light (GFCI) on thermostat is ON and power to the load is cut-off (flames remain on display though). If these events do not occur, check the installation. Press on RESET button to reset the GFCI. INSTALLATION Parts included: One (1) TH111GFCI-NP (120 VAC) thermostat Two (2) 6-32 screws Four (4) Solderless connectors (for copper wire) One (1) Temperature sensor with a 15 foot extension TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. KEEP AIR VENTS OF THE THERMOSTAT CLEAN AND OBSTRUCTION FREE. This thermostat should be installed by an electrician or experienced technician. The thermostat must be used with a circuit breaker or fuse. This thermostat was designed to control floor electric heating systems. The resistive load must not exceed 2000 watts @ 120 VAC (16.7 A). The thermostat is equipped with a ground fault circuit interrupter (GFCI) and therefore the isolation of the line and load is required for operation. The polarity of line connection must be respected. During a ground fault, only the current in the black wire of the load will be cut-off from the 120 V line. Connect thermostat as shown on diagram. 1) CONNECTING WIRES AND MOUNTING THERMOSTAT Connect the rear thermostat wires to the power supply and to the load using solderless connectors for copper wires. See schematic diagram. Push the excess wire back into the electrical box to prevent interference withthe thermostat. Secure the thermostat using two (2) 6-32 screws 1 1/4 inches long. Once the thermostat is properly installed, return power to heating system. 2) CONNECTING TEMPERATURE SENSOR WIRE Connect the sensor wire to the two lower screws of the terminal block at the back of the thermostat (no polarity need to be respected). The wire must pass outside the electrical box and follow the wall down to the floor. The sensing probe should be placed in a representative heat area for maximum system perfomance. The sensing probe should be centered between the wires in the mat. The probe wire cannot cross any heater wires and the temperature sensor must not be directly or adjacent to a heating wire. VAC 120 60 HZ CHOOSING THE TEMPERATURE SCALE IN °C (CELSIUS) OR °F (FAHRENHEIT) TO APPEAR ON DISPLAY. Set the temperature switch at the back of the thermostat to °C or °F at your preferences. 720-111715-B 1/2 • Recording a setpoint temperature for the (ECONOMIC) setting Select chosen setpoint temperature by using and buttons. Keep pressing on the button (2 to 3 seconds) until icon appears on display. • Recording a setpoint temperature for the (VACATION) setting To program the Vacation temperature, select the desired degree using the buttons and press on the and buttons simultaneously until the icon is displayed (app. 3 seconds). NOTE: When the temperature setting used is or or , you can still use the or buttons to change the setpoint temperature without changing the recorded temperature. • Recalling stored setpoint temperatures Once stored, the setpoint temperatures can be recalled simply by selecting the or button or both and for setpoint. CHARACTERISTICS Model: TH111GFCI-NP (120 VAC) Supply: 120 VAC, 50/60 Hz Load: 16.7 A maximum (resistive only) Power: 2000 watts @ 120 VAC Ground fault circuit interrupter (GFCI): Class A (5 MA TRIP LEVEL) Approvals: CSA/C, US Display range: 0 to 60 .C (32 °F to 140 .F) Setting range: 5 °C to 40 .C (40 °F to 104 .F) Default setting: 28 °C (82 °F) Default setting: 18 °C (64 °F) Storage: -20 °C to 50 .C (-4 °F to 120 .F) Temperature regulation: 1 .C (2 °F) Precision: ± 0.5 .C (1 °F) (2000 W) AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTY This product is warranted against material defects and workmanship in normal use for a period of one year, from the date of the original purchase from authorized dealers. During this period, AUBE technologies inc. will repair or replace the product with a new or of equivalent quality at AUBE'S option, without charge, any product proven defective in normal use. Warranty does not cover transportation costs. Nor does it cover a product subjected to misuse or accidental da...

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien