|
Anleitung Zusammenfassung
The AM / PM indicator will not be displayed in 24 hour mode. Both the current time and all programs will automatically change to the selected format. PROGRAMMING The following time and temperature settings are pre-programmed into the thermostat: Temperature in C° (F°) Program Number Time Heat Cool 1 6:00 am 20°C (68°F) 26°C (78°F) 2 8:00 am 16°C (60°F) 29°C (85°F) 3 4:00 pm 20°C (68°F) 26°C (78°F) 4 10:00 pm 16°C (60°F) 28°C (82°F) ¦ All 7 days of the week have the same default programs. Personal Program Schedule ¦ You can revise the factory programs to match your own schedule. Use this Personal Program Schedule to determine which times and temperature settings match your comfort and energy saving requirements. Use a pencil so you can revise your records each time you change your program settings. Heating Day Program 1 Program 2 Program 3 Program 4 Monday – Friday Time Temp Time Temp Time Temp Time Temp Saturday Time Temp Time Temp Time Temp Time Temp Sunday Time Temp Time Temp Time Temp Time Temp Cooling Day Program 1 Program 2 Program 3 Program 4 Monday – Friday Time Temp Time Temp Time Temp Time Temp Saturday Time Temp Time Temp Time Temp Time Temp Sunday Time Temp Time Temp Time Temp Time Temp Revising Programs ¦ Familiarize yourself with manually changing programs, so that you can easily modify the programs as your comfort needs change. Follow the steps below to change the program times and temperatures. NOTE: 1) The program time can be set in 10-minute increments. 2) The program temperature can be set in increments of 1°C (1°F). 3) After 15 seconds without a key press, the thermostat will return to normal display mode. 4) When setting the program time, note the AM / PM indicator. STEP 1: system heat off cool ¦ Slide the System Switch to the HEAT or COOL position to program the corresponding system. NOTE: If the System Switch is in the OFF position, the last position used will be programmed. STEP 2: program ¦ Press to enter program mode. HEAT or COOL will be displayed on the LCD. STEP 3: ¦ The Program hour and AM or PM indicator are flashing. Press to change the hour. STEP 4: program ¦ Press again to change to the minute position. The current minute will be flashing. ¦ Press to change the minute. STEP 5: program ¦ Press again to change to the program temperature. The current temperature will be flashing. ¦ Press to change the temperature. STEP 6: program program hold /return SA PM TEMP 2 MT WTHF AM 1 HEAT MT WTHF AM 1 HEAT MT WTHF AM 1 HEAT ¦ Press again to move to the next program number. ¦ Repeat Steps 3 through 5 to change the remaining Weekday, Saturday, and Sunday programs. (There are a total of 12 programs.) ¦ After cycling through all 12 programs, press again to return the display to normal. ¦ Press at any time to exit the Program Mode. ® Reviewing Programs To review your program settings, press program repeatedly to cycle through the programs. You can also make changes at any time. System Selector Switch The System Selector switch on the front of the thermostat determines the operating mode of the thermostat. You may select COOL, OFF, HEAT. NOTE: Anytime you install or remove the thermostat from the wallplate, slide the System Selector to the OFF position to prevent the possibility of a rapid system On-Off. Fan Switch The Fan switch should normally be located in the AUTO position. The Fan will be turned on along with normal operation of your system. In a normal gas or oil furnace, the Fan will be turned on by your furnace after its warm-up delay. For electric heat, air conditioning, and heat pump operation, the Fan will turn on with the system. system heat off cool fan auto on To run the Fan on continuously, slide the Fan switch to the ON position. Temporary Manual Override To temporarily change the current set temperature without affecting your program: ¦ Press and hold for about 1 second SET TEMP to enter Manual Override mode. When or display flashes, you can release the key. 3 COOL TEMP ¦ Press again to change to your desired Set Temperature. Hold the key for 2 seconds to or fast-advance the Set Temperature. hold ¦ Press to return to normal mode, or wait 5 seconds for it to return automatically. /return ¦ The current program number will flash to SA signify the Temporary Override. PM ¦ At the next program change time, the Temporary Override is cancelled, and the next program temperature becomes the setpoint 3COOL TEMP temperature. To end the Temporary Manual Override: hold ¦ Press, then press again. This will return the set temperature to the current program set temperature. /return Permanent Override To hold your Manual Override for vacation or just an extended period of time: /return ¦ Press to make the current program temperature the HOLD temperature. HOLD will be displayed on the LCD, and the Program number will disappear. ¦ Follow the Temporary Manual Override instructions above to change the Permanent Manual Override temperature. ¦ You can confirm the held set temperature by pressing fo...
Dieses Handbuch ist für folgende Modelle:Steuerungen & Regelgeräte - 47250A (309.69 kb)
Steuerungen & Regelgeräte - 47250A (309.69 kb)