Anleitung Hunter Fan, modell RC-2000

Hersteller: Hunter Fan
Dateigröße: 340.49 kb
Dateiname: RC-2000_Installation_Manual.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


• When connecting to an HAI Home Control system or remote switch, this jumper must be installed. • When connecting to a PC or other device with a serial port, this jumper must be removed. COMM JUMPER J8 COMMUNICATIONS JUMPER FIGURE 11 – COMMUNICATIONS JUMPER HAI HOME CONTROL SYSTEMS The thermostat can be connected to an HAI Home Control system. The controller can send commands to the thermostat to change mode, cool setting, heat setting, status of fan and hold, and other items. Run a 3 (or 4) conductor wire from the HAI system to the thermostat location. All thermostats on an HAI Home Control system are connected to Ground, Zone +16, and Output 8 -See Figure 12. THERMOSTAT CONTROLLER Black Green Yellow UP Communication Jumper Figure 12 – Connections to HAI Home Control System Notes: 1. Additional thermostats are connected in parallel. They may be connected in home-run or daisy chain configuration. 2. When connecting to an HAI Home Control System, the communications jumper (J8) labeled “COMM JUMPER” on the thermostat printed circuit board must be in place. 3. All thermostats on an OmniLT controller are connected to the GRN (Green), BLK (Black), and YEL (Yellow) terminals under the section marked "TSTAT". REMOTE SETBACK SWITCH The thermostat can be connected to a remote switch to toggle the desired heat and cool temperature settings between preset setpoints. A signal can be sent from the remote switch location to change the thermostat temperature settings from the Occupancy Day temperature settings to the Occupancy Night temperature settings. To use this mode, the “Program Options” setting must be set to “Occupancy” -See Program Options. Run a two-conductor wire from the remote switch to the thermostat location. Make the connections to the Black and Green terminals under the section marked “Comm” on the right terminal strip -See Figure 13. ANY SYSTEM WITH THERMOSTAT UP Green Black A RELAY OR 5 - 15 VDC OUTPUT 5 -15 VDC Communication Jumper Figure 13 – Connections to a Remote Setback Switch Notes: 1. When connecting to a remote setback switch, the communications jumper (J8) labeled “COMM JUMPER” on the thermostat printed circuit board must be in place. 2. When 0VDC is applied, the desired temperature settings will change to the preset Occupancy Day temperature settings. 3. When 5-15VDC is applied, the desired temperature settings will change to the preset Occupancy Night temperature settings. OTHER SYSTEMS For connections to personal computers, utility management systems, and other automation systems, refer to connection diagrams provided with personal computer software package or other system. REMOTE TEMPERATURE SENSOR A remote temperature sensor can be installed to monitor the temperature from a remote location or can be combined with the onboard temperature sensor for the average temperature of two locations. Run a twisted pair, shielded cable from the RC-2000 to the remote temperature sensor location. For distances up to 100 feet, typical twisted pair, PVC-insulated, shielded cable may be used. For distances from 100-150 feet, twisted pair with polypropylene insulated conductors, shielded must be used. For distances from 150-250 feet, twisted pair with foam-polyethylene insulated conductors, shielded must be used. Wire runs must not exceed 250 feet. Make the connections to the Green and Black terminals under the section marked “Remote Temp Sensor” on the right terminal strip -See Figure 14. THERMOSTAT UP Black Green Communication Jumper Figure 14 – Connections to a Remote Temperature Sensor Notes: 1. When connecting a remote temperature sensor, the shield and one of the wires from the remote temperature sensor are tied together and get connected to the Black terminal – See Figure 14. 2. At the location of the temperature sensor, wrap the shield around the jacket of the cable and tape. 3. Configure the temperature sensor according to the application – See “Temperature Sensors” under Installation Settings. DISABLE LOCAL CONTROL The Task Buttons and Scroll Wheel on the thermostat can be disabled to prevent anyone from controlling the thermostat locally. To disable the Task Buttons and Scroll Wheel: 1. Remove the thermostat face from the thermostat base. 2. Remove the local control jumper -See Figure 15. 3. Align the tabs of the thermostat face with the slots of the thermostat base. Gently push the thermostat face into the thermostat base locking it into place. COMM JUMPER J8 TO DISABLE TASK BUTTONS AND SCROLL WHEEL REMOVE JUMPER Figure 15 – Local Control Jumper SETUP AND CONFIGURATION NOTE: For proper operation of the features of this thermostat, the Time and Date must be set. Even when connected to an HAI controller which sets the time and day, the Date must be manually set in the thermostat under the “Settings” menu. INSTALLATION SETTINGS This section describes the items that the installer must setup as part of the thermostat installation. The Installation Settings menu is used to configure the operating pa...

Dieses Handbuch ist für folgende Modelle:
Steuerungen & Regelgeräte - RC-2000 (340.49 kb)
Steuerungen & Regelgeräte - RC-2000 (340.49 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien