Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.7 ( )

Anleitung Hunter Fan, modell 43168

Hersteller: Hunter Fan
Dateigröße: 915.18 kb
Dateiname: 44014.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


• If the wiring to the thermostat has been correctly connected, and if the thermostat has been correctly mounted to the wallplate, then the LCD Display should show the indoor room temperature. THERMOSTAT CONTROLS • Open the thermostat’s front cover. See Figure 6. Figure 6 Switches and Buttons K J A I B sys aux em H program system G day/time em heat F filter fan heat auto off refresh cool E hold/rtrn C reset on D Switches and Buttons A LCD Readout - displays indoor temperature, set temperature, and information about the heat pump system’s operation and status. B System Switch - “em heat” is the Emergency Heat. NOTE: The Emergency Heat Mode is not an energy saving mode, so use it only when necessary. “heat” is the normal heat mode. “off” turns the system off. “cool” is the normal cooling mode. C Fan Switch - In Auto mode, the fan runs when the system is on for heating or cooling. The Refresh mode sets the fan to run automatically at intervals of 10, 15, 20, or 30 minutes out of every hour when the system is not running for heating or cooling. In the On mode, the fan runs continuously regardless of system status. D Reset button - push the Reset button with the end of a paper clip to reset the thermostat and return to its factory default settings. E Hold/Return button - used for setting a permanent (vacation) hold, and for returning to the normal display from Day & Time setting, Programming, or Option setting modes. F Filter button - reviews and resets the thermostat’s Filter Life Counter. G Day/Time button - used for entering the Clock Setting mode. Use with the Up and Down buttons to set the time and day. H Program button - used for entering and modifying programs. Use with the Up and Down buttons to set times and temperatures. Press when in clock mode to select between 12-hour and 24-hour clock modes. I Down button - used to change the temperature setting and the option settings. J Up button - used to change the temperature setting and the option settings. K System LED’s - for heat pump systems that have fault detection capabilities, the “sys” LED glows red when the thermostat has detected a fault through the L terminal connection from the heat pump. The “em” LED glows red when Emergency Heat is turned on. The “aux” LED glows green when the auxiliary heat is turned on. program day/time Settings The default for this thermostat setting is in a 12 hour format. You can change the format to 24 hour format by pressing Day/Time and then Program. The AM/PM indicator will be off when the thermostat is in 24 hour mode. Setting day and time: 1. Press Day/Time. (AM/PM and current hour will flash) Press Up or Down to adjust the setting. 2. Press Day/Time again to adjust the minute setting. Press Up or Down to adjust the setting. 3. Press Day/Time again to adjust the day of the week. Press Up or Down to adjust the setting. 4. Press Day/Time to return to the normal display. Press Up or Down to adjust the setting. You may also press Hold/Return at any time to return to the normal display. Methods of Operation This thermostat gives you the ability to program up to 4 custom temperature settings per day or utilize pre-programmed settings. For manual operation instructions, see pages 21-23. To utilize the pre-programmed settings, see pages 24-25. To create custom programs, see pages 26-29. Up and Down buttons Methods of Operation (cont.) 1. MANUAL OPERATION Many people prefer to operate their thermostats manually, adjusting settings as needed. You can either temporarily override the settings for the current program, or permanently override all settings and adjust temperatures manually. If you want to only temporarily override the current program: 1. Press and hold Up or Down for one second to enter Manual Override mode. (Release the button when the display flashes.) 2. Press the Up or Down buttons to adjust the temperature setting as desired. 3. The thermostat will maintain this setting until the next program starts, or 4 hours maximum. Up and Down buttons Hold icon Hold/Return hold/rtrn Methods of Operation (cont.) MANUAL OPERATION, CONT. If you want to permanently override all settings and adjust the thermostat manually: 1. Press Hold/Return until the Hold icon appears. 2. Press and hold Up or Down for one second to enter Manual Override mode. (Release the button when the display flashes.) 3. Press the Up or Down buttons to adjust the temperature setting as desired. 4. Press and release Hold/Return to return to the normal display. DEFAULT PROGRAMS CHART Program 1Heat : 68o F (20o C) Cool : 78o F (26o C) Program 2Heat : 60o F (16oC) Cool : 85o F (29o C) Program 3Heat : 68o F (20o C) Cool : 78o F (26o C) Program 4Heat : 60oF (16o C) Cool : 82oF (28oC) 10 pm6 am8 am4 pm Methods of Operation (cont.) 2. DEFAULT PROGRAMS This thermostat meets ENERGY STAR guidelines for energy efficiency. By using the pre- programmed settings, this thermostat can save you money by optimizing energy usage in heating and cooling. Refer to the Default ...

Dieses Handbuch ist für folgende Modelle:
Steuerungen & Regelgeräte - 43168 (915.18 kb)
Steuerungen & Regelgeräte - 43168 (915.18 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien