Anleitung American Standard, modell asystat 570
Hersteller: American Standard Dateigröße: 288.11 kb Dateiname: 25dca757-8d52-488f-8552-e88399bab0dc.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
No. 12-5018-01 69-1324 FEATURES American Standard sells comfort systems. Comfort is achieved through matching the correct equipment and controls. This thermostat is designed to provide the maximum comfort for your needs. Some of the basic offerings are: • Simple and easy to use. The and keys make it easy for you to change your temperature setting. • Large digital display. You can easily read the current room temperature at a glance. • No need for batteries. Batteries are not required because your temperature settings are held permanently in memory. 2 Pub. No. 12-5018-01 69-1324 SETTINGS Setting SYSTEM and FAN Switches System and fan settings are controlled by using SYSTEM and FAN switches located on the bottom of the thermostat case. First set the SYSTEM switch: Cool: Normal setting for months when your home needs cooling (air conditioning). Digital display shows a snowflake when cooling is on. Off: Both heating and cooling are off. Heat: Normal setting for months when your home needs heating. Digital display shows a flame when heating is on. Em. Ht.: Switch to this setting when your home needs heat, but your equipment needs servicing or is not working properly. In this mode, the thermostat controls only the backup heat. The heat pump is off. SYSTEM Cool Off Heat Em.Ht. SYSTEM SWITCH M10274 3 Pub. No. 12-5018-01 69-1324 points to Em Ht when the system is in Then set the FAN switch: Auto: Normal setting for most homes. Some systems may delay the fan turning on and off with the equip- emergency heat mode. The indicator may also point to Aux Ht if the system calls for additional back-up heating. ment. INDICATOR On: The fan runs continuously. Use for improved air circulation and air Em Ht quality. Aux Ht FAN Auto On Set Room M10287 SWITCH M10273 FAN Auxiliary Heat The auxiliary heaters assist the heat pumpEmergency Heat under normal conditions when low outdoor The Emergency Heat feature allows you to temperature occurs. The indicator points to “turn on” the electric heat section of the Aux Ht when the auxiliary heating equipment system by moving the system switch to the operates. Em. Ht. position. The indicator flashes and 4 Pub. No. 12-5018-01 69-1324 Displaying Temperature Setting NOTE: Your temperature setting can be set anywhere from 50° to 99°F (10° to 37°C). The temperature setting and the room temperature display separately. The indicator points to Set when the temperature setting displays, and to Room when the room temperature displays. The thermostat displays room temperature unless or is pressed. 1. To display the temperature setting on the digital display, press either the or key once. Changing Temperature Setting 1. To lower the temperature setting, press the key. When in the heating mode, lowering the temperature at night or during the day can lower your energy costs. Set Room M10276 Set Room M10275INDICATOR 5 Pub. No. 12-5018-01 69-1324 2. To raise the temperature setting, press the key. When in the cooling mode, raising the temperature before you leave for work or school also lowers your energy costs. Set Room M10277 CAUTION Equipment Damage Hazard. Can cause permanent damage to the compressor or other equipment. To avoid possible equipment damage, do not operate cooling when outside temperature is below 50°F (10°C). See equipment manufacturer instructions. To avoid possible compressor damage, allow the compressor to remain off for five minutes before restarting. 6 Pub. No. 12-5018-01 69-1324 TROUBLESHOOTING GUIDE Symptom Action Heating or Cooling will not come on. Check that the SYSTEM switch on the thermostat is set to Heat or Cool. Check if the circuit breaker is tripped—reset the circuit breaker. Check if the fuse is blown—replace the fuse. Check for air movement at the register. Check power to the heating or cooling equipment. Temperature setting is too warm or cool. Adjust the temperature by pressing either the or key. 7 Pub. No. 12-5018-01 69-1324 LIMITED WARRANTY Low Voltage Room Thermostats This warranty is extended by American Standard Inc., to the original purchaser and to any succeeding owner of the real property to which the Thermostat is originally affixed, and applies to products purchased and retained for use within the U.S.A. and Canada. If any part of your Thermostat fails because of a manufacturing defect within one year from the date of the original purchase, Warrantor will furnish, without charge, a new thermostat. Any local transportation, related service labor and diagnosis calls are not included. This warranty does not cover failure of your Thermostat if it is damaged while in your possession or if the failure is caused by unreasonable use. In no event shall Warrantor be liable for incidental or consequential damages. In no event shall any implied warranty of merchandise or fitness for use exceed the terms of the limited warranty stated above. 8 Pub. No. 12-5018-01 69-1324 Some states do not allow limitations on how long an implied warranty lasts or do not al...