Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Hobart Welding Products, modell 1025

Hersteller: Hobart Welding Products
Dateigröße: 794.62 kb
Dateiname: o2210k_hob.pdf
Unterrichtssprache:enfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


2-2. Manufacturer’s Rating Label For CE Products S-181 265-A EN 60974-1 X 100% 35% 16A/86V 27A/90V U0 = 255V I2 16A 27A U2 86V 90V IP 23 50 Hz1 I1max = 34AU1 = 115V I1max = 17AU1 230V I1eff = 20.5A I1eff = 10.2A 1 2-3. Symbols And Definitions A Amperes Plasma Arc Cutting (PAC) Adjust Air/Gas Pressure Low Air Pressure Light V Volts Increase No . Do Not Do This Temperature Protective Earth (Ground) Single Phase Constant Current Voltage Input On Off Percent Direct Current U0 Rated No Load Voltage (Average) U1 Primary Voltage U2 Conventional Load Voltage Line Connection I1max Rated Maximum Supply Current I2 Rated Welding Current X Duty Cycle Single Phase Static Frequency Converter- Transformer- Rectifier IP Degree Of Protection Loose Shield Cup Input Hz Hertz I1eff Maximum Effective Supply Current OM-2210 Page 10 SECTION 3 . INSTALLATION 3-1. Specifications For Units Connected to a 20 Ampere, 115 Volt Circuit or a 10 Ampere, 230 Volt Circuit Rated Output Amperes Input at Rated Output, 60 Hz, Single-Phase 1 11 15 V 15 V15 V KVA/KW 230 V 230 V230 V KVA/KW Plasma PlasmaPlasma Gas Plasma Gas Flow/ Gas Flow/Gas Flow/ Pressure Rated Cutting Capacity CapacityCapacity at 10 IPM Max MaxMax OCV115 V 230 V 21 A at 88 Volts DC At 35% Duty Cycle 25.3 max; 15 eff 12.6 max; 7.5 eff 2.9 KVA 2.2 KW 2.9 KVA 2.2 KW Air Or Nitrogen Only 4.5 CFM (129 L/min) At 60 PSI (414 kPa) 115 VAC Input: 1/4 in (6 mm); 230 VAC Input: 5/16 in (8 mm) 265 Volts DC 3-2. Specifications For Units Connected to a 30 Ampere, 115 Volt Circuit or a 15 Ampere, 230 Volt Circuit If the unit is operated from a 30 ampere, 115 volt circuit or a 15 ampere, 230 volt circuit, a different input power plug must be installed on the power cord. See Section 3-9 for instructions. NOTE Rated Output Amperes Input at Rated Output, 60 Hz, Single-Phase 1 11 15 V 15 V15 V KVA/KW 230 V 230 V230 V KVA/KW Plasma PlasmaPlasma Gas Plasma Gas Flow/ Gas Flow/Gas Flow/ Pressure Rated Cutting Capacity CapacityCapacity at 10 IPM Max MaxMax OCV115 V 230 V 27 A at 91 Volts DC At 35% Duty Cycle 33.6 max; 19.9 eff 16.8 max; 9.9 eff 3.8 KVA 3.1 KW 3.8 KVA 3.1 KW Air OrAir Or Nitrogen OnlyOnly 4.5 CFM 4.5 CFM4.5 CFM (129 L/min) At 60 PSI (414 kPa)(414 kPa) 115 VAC Input: 1/4 in Input: 1/4 inInput: 1/4 in (6 mm); 230 VAC Input: 5/16 inInput: 5/16 in (8 mm) 265 Volts DC 21 A at 88 Volts DC At 60% Duty Cycle 25.3 max; 19.6 eff 12.6 max; 9.8 eff 2.9 KVA 2.2 KW 2.9 KVA 2.2 KW 17 A at 87 Volts DC At 100% Duty Cycle 20.9 max; 20.9 eff 10.5 max; 10.5 eff 2.4 KVA 1.8 KW 2.4 KVA 1.8 KW 3-3. Specifications For CE Model Amperes Input at Rated Output, 50 Hz, Single-Phase Plasma Rated Output KVA KW Plasma PlasmaPlasma Gas Gas Flow/Gas Flow/ Pressure Max MaxMax OCV IP IPIP Rating115 V 230 V 115 VAC Input: 20 A @ 89 Volts DC (20 A Input Circuit); 25 A @ 89 Volts DC (30 A Input Circuit); 230 VAC Input: 25 A @ 89 Volts DC; 35% Duty Cycle In All Cases 26 (0.4*) 17 (0.2*) 115 VAC Input: 3.1 (0.05*) 230 VAC Input: 4.0 (0.05*) 115 VAC Input: 2.4 (0.04*) 230 VAC Input: 3.1 (0.04*) Air Or Nitrogen Only 4.5 CFM (129 L/min) At 60 PSI (414 kPa) 265 Volts DC 23 *While idling OM-2210 Page 11 OM-2210 Page 12 3-4. Duty Cycle And Overheating For Non-CE Model Duty Cycle is percentage of 10 minutes that unit can cut at rated load without overheating. If unit overheats, thermostat(s) opens, output stops, Temperature trouble light goes On, and cooling fan runs. Wait fifteen minutes for unit to cool or temperature light to go off. Reduce amperage or duty cycle before cutting or gouging. Exceeding duty cycle can damage unit and void warranty. Overheating sduty1 5/95 3-1/2 Minutes Cutting 6-1/2 Minutes Resting 35% Duty Cycle At 27 Amperes, 91 volts dc 0 15 A OR Minutes Reduce Duty Cycle 6 Minutes Welding 4 Minutes Resting Continuous Welding 60% Duty Cycle At 21 Amperes, 88 volts dc 100% Duty Cycle At 17 Amperes, 87 volts dc 35% duty cycle 60% duty cycle 100% duty cycle For Units Connected to a 20 Ampere, 115 Volt Circuit or a 10 Ampere, 230 Volt Circuit: For Units Connected to a 30 Ampere, 115 Volt Circuit or a 15 Ampere, 230 Volt Circuit: 35% Duty Cycle At 21 Amperes, 88 volts dc 3-5. Duty Cycle And Overheating For CE Model Duty Cycle is percentage of 10 minutes that unit can cut at rated load without overheating. If unit overheats, thermostat(s) opens, output stops, Temperature trouble light goes On, and cooling fan runs. Wait fifteen minutes for unit to cool or temperature light to go off. Reduce amperage or duty cycle before cutting or gouging. Exceeding duty cycle can damage unit and void warranty. Overheating duty1 4/95 . Ref. ST-159 463-B 230 VAC Input Power: 35% Duty Cycle At 25 Amperes 3-1/2 Minutes Cutting 6-1/2 Minutes Resting 0 15 Minutes A OR Reduce Duty Cycle 115 VAC Input Power: 35% Duty Cycle At 20 Amperes, 20 Ampere Input Circuit 115 VAC Input Power: 35% Duty Cycle At 25 Amperes, 30 Ampere Input Circuit OM-2210 Page 13 18 in (457 mm) 3-6. Selecting A Location loc_2 3/96 - ST-801 303-B / ST-801 319-B 1 Lifting H...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien