Curves of all other settings fall between the curves shown. A. For CC/AC Mode B. For CC/DC Mode 0 0 50 100 150 200 250 300 350 400 10 20 30 40 50 60 70 80 AC VOLTS AC AMPERES A B C RANGES A = 85.225 B = 70.150 C = 50.100 0 10 20 30 40 50 60 70 80 DC VOLTS 0 50 100 150 200 250 300 350 400 DC AMPERES A C B RANGES A = 85.225 B = 70.150 C = 50.100 4-8. Generator Power Curve 240 425-A The generator power curve shows the generator power in amperes available at the receptacles. A complete Parts List is available at wwwHobartWelders.com OM-240 438 Page 20 SECTION 5 . INSTALLATION 5-1. Serial Number And Rating Label Location The serial number and rating information for this product is located on the back. Use rating label to determine input power requirements and/or rated output. For future reference, write serial number in space provided on back cover of this manual. ! Do not move or operate unit where it could tip. ! Do not lift unit from end. ! Do not weld on base. Welding on base can cause fuel tank fire or explosion. Bolt unit down using holes provided in base. ! Always securely fasten welding generator onto transport vehicle or trailer and comply with all DOT and other applicable codes. NOTICE . Do not install unit where air flow is restricted or engine may overheat. See Section 4-2 for lifting eye rating. Mounting: ! Do not mount unit by supporting the base only at the four mounting holes. Do not use flexible mounts. Use crosssupports to adequately support unit and prevent damage to base. 1 Cross-Supports Mount unit on flat surface or use cross-supports to support base, see Section 4-2. install2 2008-01 . Ref. 800 652 / Ref. 800 477-A / 803 274-A / 804 712 OR 18 in. (460 mm) 18 in. (460 mm) 18 in. (460 mm) 18 in. (460 mm) 18 in. (460 mm) OR Movement Location / Airflow Clearance 5-2. Installing Welding Generator Mounting OR 1 A complete Parts List is available at OM-240 438 Page 21 ! Always ground generator frame to vehicle frame to prevent electric shock and static electricity hazards. ! Also see AWS Safety & Health Fact Sheet No. 29, Grounding of Portable And Vehicle Mounted Welding Generators. ! Bed liners, shipping skids, and some running gear insulate the welding generator from the vehicle frame. Always connect a ground wire from the generator equipment grounding terminal to bare metal on the vehicle frame as shown. ! If unit does not have GFCI receptacles, use GFCI-protected extension cord. 1 Equipment Grounding Terminal (On Front Panel) 2 Grounding Cable (Not Supplied) 3 Metal Vehicle Frame Connect cable from equipment ground terminal to metal vehicle frame. Use #10 AWG or larger insulated copper wire. Electrically bond generator frame to vehicle frame by metal- to-metal contact. 5-3. Grounding Generator To Truck Or Trailer Frame rot_grnd 2008-01 . 800 652-D 1 3 2 GND/PE A complete Parts List is available at wwwHobartWelders.com OM-240 438 Page 22 5-4. Engine Prestart Checks (Subaru-Powered Units) 244 032-A / 217 015-A Full Full Gasoline Check all fluids daily. Engine must be cold and on a level surface. Unit is shipped with 10W30 engine oil. Follow run-in procedure in engine manual. NOTICE . This unit has a low oil pressure shutdown switch. However, some conditions may cause engine damage before the engine shuts down. Check oil level often and do not use the oil pressure shutdown system to monitor oil level. Fuel Add fresh fuel before starting engine the first time (see maintenance label for specifications). Always leave filler neck empty to allow room for expansion. Check fuel level on a cold engine before use each day. Oil Do not exceed the ”Full” mark on the oil level dipstick. The fuel pump may operate erratically if crankcase is overfilled. After fueling, check oil with unit on level surface. If oil is not up to full mark on dipstick, add oil (see maintenance label). To improve cold weather starting: Keep battery in good condition. Store battery in warm area. Use correct grade oil for cold weather. Oil Check Oil Fill A complete Parts List is available at OM-240 438 Page 23 5-5. Engine Prestart Checks (Kohler-Powered Units) 244 033-A / 217 015-A Check all fluids daily. Engine must be cold and on a level surface. Unit is shipped with 10W30 engine oil. Follow run-in procedure in engine manual. NOTICE . This unit has a low oil pressure shutdown switch. However, some conditions may cause engine damage before the engine shuts down. Check oil level often and do not use the oil pressure shutdown system to monitor oil level. Fuel Add fresh fuel before starting engine the first time (see maintenance label for specifications). Always leave filler neck empty to allow room for expansion. Check fuel level on a cold engine before use each day. Oil Do not exceed the ”Full” mark on the oil level dipstick. The fuel pump may operate erratically if crankcase is overfilled. After fueling, check oil with unit on level surface. If oil is not up to full mark on dipst...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien