Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung Carrier, modell 38AH044 38AH044-134

Hersteller: Carrier
Dateigröße: 3.55 mb
Dateiname: 38ah-14si.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


[mm] QTY 074 208/230 60 21/2 [63] 2 460 60 2Vz [63] 1 074, 084 346, 380/415 50 35/e [92] 1 380 60 3% [92] 1 575 60 2Va [63] 1 084 208/230 60 35/e [92] 2 460 60 35/a [92] 1 LEGEND C — Copper Fin Coils MTG — Mounting SAE — Society of Automotive Engineers NOTES: 1 The approximate operating weight of the unit is: 38AH-074— 3812 lb (1729 kg) 38AH-074-C 4229 lb (1918 kg) 38AH-084— 4057 lb (1840 kg) 38AH-084-C 4735 lb (2148 kg) 2 Unit must have clearances for airflow as follows: Top — Do not restrict in any way Ends — 5 ft [1524 mm] Sides — 6 ft [1829 mm] 3 Mounting holes may be used to mount unit to concrete pad They are not recommended for mounting unit to spring isolators If spring isolators are used, a perimeter support channel between the unit and the isolators Is recommended 4 See Table 1 for rigging center of gravity (Dimensions X,Y) See Table 2A and 2B for A-D corner weights 5 Circled numerals in Top View refer to condenser fans by position Fig. 2 — Dimensions — Units 38AH074,084 5 000000000100020202010201010100000002020002020201020101010100 ooooooOOOOO o OOOO VIEW 5-5 TOP VIEW OF CONTROL BOX SHELF WITH FIELD POWER SUPPLY CONNECTIONS RELIEF VALVES LOCATED ON COMPRESSORS A2 AND B1 ARE EQUIPPED WITH A 3/8' SAE FLARE FOR FIELD CONNECTION SCALE 1:8 (8) MTG HOLES 7/32' D1A 7'-11 9/16' [2428mmD -7 -4 11/16'- [22S2mir] HTG HOLES -7'-7 11/16'- £2326mm} BASE OVERALL LEFT-END VIEW RIGHT-END VIEW Chart 1, Field Power Supply Connections UNIT 38AH VOLTAGE Hz DIAMETER — in. (mm) QUANTITY 094 208/230 60 3% (92) 2 460, 575, 380 60 3% (92) 1 346, 380/415 50 3% (92) 1 LEGEND C — Copper Fin Coils MTG — Mounting SAE — Society of Automotive Engineers NOTES: 1 The approximate operating weight of the unit is: 38AH-094— 5088 lb (2308 kg) 38AH-094-C 5813 lb (2637 kg) 2 Unit must have clearances for airflow as follows: Top — Do not restrict in any way Ends — 5 ft [1524 mm] Sides — 6 ft [1829 mm] 3 Mounting holes may be used to mount unit to concrete pad They are not recommended for mounting unit to spring isolators 4 Two 35/e" (92-mm) dia holes are recommended for parallel conductors on 208/230 v units. 5. Circled numerals in Top View refer to condenser fans by position 6 If spring isolators are used, a perimeter support channel between the unit and the isolators is recommended 7. See Table 1 for rigging center of gravity (Dimensions X,Y) See Table 2A and 2B for A-D corner weights Fig. 3 — Dimensions — Unit 38AH094 6 VIEW 5-5 TOP VIEW OF CONTROL BOX SHELF WITH FIELD POWER SUPPLY CONNECTIONS RELIEF VALVES LOCATED ON COMPRESSORS A2 AND B2 ARE EQUIPPED WiTH A 3/8' SAE FLARE FOR F1ELO CONNECTION SCALE 1:8 CONTROL BOX END (8) MTG HOLES 17/32' DIA [1 3 mm] HINGED ACCESS PANEL (CONTROL SIDE) HINGED ACCESS PANEL (POWER SIDE) -7 -4 11/16 - 12252mm] MTG H0LE5 -7 -7 11/16'- [2328mtnJ BASE OVERALL LEFT-END VIEW 7 ' -11 9/16' 12428mm] -1 1/2 [38mm] MTG HOLES BASE OVERALL RIGHT-END VIEW Chart 1, Field Power Supply Connections UNIT 38AH VOLTAGE Hz DIAMETER — in. (mm) QUANTITY 104 208/230 60 3% (92) 2 460, 575, 380 60 3% (92) 1 346, 380/415 50 3% (92) 1 LEGEND C — Copper Fin Coils MTG — Mounting SAE — Society of Automotive Engineers NOTES: 1 The approximate operating weight of the unit is: 38AH-104— 5435 lb (2465 kg) 38AH-104--C 6160 lb (2794 kg) 2 Unit must have clearances for airflow as follows: Top — Do not restrict in any way Ends — 5 ft [1524 mm] Sides —6 ft [1829 mm] 3 Mounting holes may be used to mount unit to concrete pad They are not recommended for mounting unit to spring isolators 4 Two 3%" (92-mm) dia holes are recommended for parallel conductors on 208/230 v units 5 Circled numerals in Top View refer to condenser fans by position 6. If spring isolators are used, a perimeter support channel between the unit and the isolators is recommended 7 See Table 1 for rigging center of gravity (Dimensions X,Y) See Table 2A and 2B for A-D corner weights Fig. 4 — Dimensions — Unit 38AH104 LEFT-END VIEW : О CENTER OF GRAVITY -К- CENTER OF GRAVITY CONTROL BOX END MODULE 124B TOP VIEW SEE NOTE 8 Chart 1, Field Power Supply Connections UNIT 38AH VOLTAGE Hz DIAMETER (in.) QUANTITY 124A 124B 208/230 60 3% (92) 1 460, 575, 380 60 21/г (63) 1 346, 380/415 50 3% (92) 1 LEGEND C — Copper Fin Coils MTG — Mounting SAE — Society of Automotive Engineers NOTES: 1 The approximate operating weight of the unit is: 38AH-124— 7260 lb (3293 kg) 38AH-124-C 8126 lb (3686 kg) 2 Unit must have clearances for airflow as follows: Top — Do not restrict in any way Ends — 5 ft [1524 mm] Sides — 6 ft [1829 mm] 3 Mounting holes may be used to mount unit to concrete pad They are not recommended for mounting unit to spring isolators 4 One 35/s" (92-mm) dia hole is recommended for single-entry power into each module (124A and 124B) of the 208/230-v units 5 Circled numerals in Top View refer to condenser fans by position 6 If spring isolators are use...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien