Anleitung Zusammenfassung


After the battery is charged, reconnect the positive battery cable first and the negative cable last. Failure to do so can result in damage to the internal charger components. Follow the instructions of the battery charger manufacturer for proper charger settings and charging time. SERVICING MUFFLER WITH INTERNAL SPARK ARRESTOR Clean every 100 hours. Remove screw plug on muffler body and either vacuum out OR shake out until clean. WARNING • MUFFLER MAY bE HOT • ALLOW ENGINE TO COOL bEFORE INSTALLING THE SPARK ARRESTER! • DO NOT OPERATE ENGINE WHILE INSTALLING THE SPARK ARRESTOR! AIR VANTAGE® 500 KUbOTA D-6 D-6 MAINTENANCE WELDER / GENERATOR GFCI MODULE TESTING AND RESETTING PROCEDURE MAINTENANCE STORAGE: Store in clean, dry protected areas. CLEANING: Blow out the generator and controls periodically with low pressure air. Do this at least once a week in particularly dirty areas. bRUSH REMOVAL AND REPLACEMENT: It’s normal for the brushes and slip rings to wear and darken slightly. Inspect the brushes when a generator overhaul is necessary. CAUTION • Do not attempt to polish slip rings while the engine is running. WARNING • Service and Repair should only be performed by Lincoln Electric Factory Trained Personnel. Unauthorized repairs performed on this equipment may result in danger to the technician and machine operator and will invalidate your factory warranty. For your safety and to avoid Electrical Shock, please observe all safety notes and precautions. The GFCI module should be properly tested at least once every month or whenever it is tripped. To properly test and reset the GFCI module: • If the module has tripped, first carefully remove any load and check it for damage. • If the equipment has been shut down, it must be restarted. ± The equipment needs to be operating at high idle speed and any necessary adjustments made on the control panel so that the equipment is providing at least 80 volts to the receptacle input terminals. • The circuit breaker for this receptacle must not be tripped. Reset if necessary. • Push the "Reset" button located on the GFCI module. This will assure normal GFCI operation. ± Plug a night-light (with an "ON/OFF" switch) or other product (such as a lamp) into the Duplex receptacle and turn the product "ON". • Push the "Test" button located on the GFCI module. The night-light or other product should go "OFF". • Push the "Reset" button, again. The light or other product should go "ON" again. If the light or other product remains "ON" when the "Test" button is pushed, the GFCI module is not working properly or has been incorrectly installed (miswired). If your GFCI module is not working properly, contact a qualified, certified electrician who can assess the situation, rewire the GFCI module if necessary or replace the device. TAbLE D.1 ENGINE MAINTENANCE COMPONENTS AIR VANTAGE® 500 KUbOTA E-1 E-1 TROUbLESHOOTING HOW TO USE TROUbLESHOOTING GUIDE WARNING Service and Repair should only be performed by Lincoln Electric Factory Trained Personnel. Unauthorized repairs performed on this equipment may result in danger to the technician and machine operator and will invalidate your factory warranty. For your safety and to avoid Electrical Shock, please observe all safety notes and precautions detailed throughout this manual. This Troubleshooting Guide is provided to help you Step 3. RECOMMENDED COURSE OF ACTION locate and repair possible machine malfunctions. This column provides a course of action for the Simply follow the three-step procedure listed below. Possible Cause, generally it states to contact your local Lincoln Authorized Field Service Facility. Step 1. LOCATE PROBLEM (SYMPTOM). Look under the column labeled PROBLEM (SYMP- If you do not understand or are unable to perform the TOMS) . This column describes possible symptoms Recommended Course of Action safely, contact your that the machine may exhibit. Find the listing that local Lincoln Authorized Field Service Facility. best describes the symptom that the machine is exhibiting. Step 2. POSSIBLE CAUSE. The second column labeled “POSSIBLE CAUSE” lists the obvious external possibilities that may contribute to the machine symptom. NOTE: See VMAC owner’s manual for compressor trouble shooting. VMAC™ VEHICLE MOUNTED AIR COMPRESSORS WWW.VMAC.CA 1333 Kipp Road Nanamino British Columbia Canada, V9X1R3 Telephone: (250) 740-3200 Facsimile: (250) 740-3201 Toll Free: 800-738-8622 CAUTION If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. AIR VANTAGE® 500 KUbOTA E-2 E-2 TROUbLESHOOTING Observe all Safety Guidelines detailed throughout this manual PRObLEMS (SYMPTOMS) POSSIbLE CAUSE RECOMMENDED COURSE OF ACTION Major Physical or Electrical Damage is Evident. 1. Contact your local Lincoln Authorized Field Service Facility. If all recommended possible areas of misad...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien