Anleitung Aurora Electronics, modell MAGNETEK PVI-3600-OUTD-UK-F-W
Hersteller: Aurora Electronics Dateigröße: 631.85 kb Dateiname: 349d8bec-10b5-4502-ae75-4979701b6df3.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
1.0 Installation and Operator’s Manual Page 2 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) REVISION TABLE Document Revision 1.0 1.1 AuthorT. Melzl T.Melzl Date 5/1/2006 5/3/2006 Change Description First release of the document Updated Anti-Inlanding reference SAVE THESE INSTRUCTIONS ! IMPORTANT SAFETY INSTRUCTIONS MAGNETEK: Reproduction and disclosure, even partially, of the contents of this manual are strictly forbidden without prior authorization of Magnetek. Installation and Operator’s Manual Page 3 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) IMPORTANT SAFETY INSTRUCTIONS This manual contains important safety and operational instructions that must be accurately understood and followed during the installation and maintenance of the equipment. To reduce the risk of electrical shock hazards, and to make sure the equipment is safely installed and commissioned, special safety symbols are used in this manual to highlight potential safety risks and important safety information. The symbols are: WARNING: the paragraphs highlighted by this symbol contain processes and instructions that must be absolutely understood and followed to avoid potential danger to people. NOTE: the paragraphs highlighted by this symbol contain processes and instructions that must be rigorously understood and followed to avoid potential damage to the equipment and negative results. The equipment is provided with several labels, some of them with a yellow background, which are related to safety issues. Make sure to read the labels and fully understand them before installing the equipment. The labels utilize the following symbols: Equipment grounding conductor (Main grounding protective earth, PE) Alternate Current (Ac) value Direct Current (Dc) value Phase Grounding (Earth) Installation and Operator’s Manual Page 4 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) USEFUL INFORMATION AND SAFETY STANDARD FOREWORD .. The installation of AURORA must be performed in full compliance with national and local standards and regulations .. AURORA has no internal user serviceable parts other than fuses. For any maintenance or repair please contact the nearest authorized repair center. Please contact your reseller if you need to know the nearest authorized repair center. .. Read and understand all the instructions contained in this manual and become familiar with the safety symbols in the relevant paragraphs before you install and commission the equipment .. The connection to the distribution grid must be done only after receiving approval from the distribution utility as required by national and state interconnection regulations, and can be done only by qualified personnel. .. Safety Brake the wind turbine to prevent any possibility of high voltages appearing at the connecting cable terminations. .. The AC disconnecting means must be opened before working on the Aurora Wind inverters. GENERAL During inverter operation, some parts can be powered, some not properly insulated and, in some cases, some parts can move or rotate, or some surfaces can be hot. Unauthorized removal of the necessary protections, improper use, incorrect installation or incorrect operation may lead to serious damage to people and objects. All transport, installation and start-up, as well as maintenance operations, shall be carried out by skilled and trained personnel (all national regulations on accidents prevention shall be complied with ! ! !). According to these basic safety rules, qualified and trained people have skills for the assembling, start-up and operation of the product, as well as the necessary requirements and qualifications to perform such operations. ASSEMBLY Devices shall be assembled and cooled according to the specifications mentioned in the corresponding documents. Installation and Operator’s Manual Page 5 of 63 (PVI-3600-OUTD-UK-F-W Rev.: 1.0) In particular, during transport and handling, parts shall not be bent and/or the insulation distances shall not be changed. There should be no contact between electronic parts and connection terminals. Electrical parts must not be mechanically damaged or destroyed (potential health risk). ELECTRICAL CONNECTION With the inverter powered, comply with all prevailing national regulations on accidents prevention. Electrical connections shall be carried out in accordance with the applicable regulations, such as conductor sections, fuses, PE connection. OPERATION Systems equipped with inverters shall be provided with further control and protective devices in compliance with the corresponding prevailing safety rules, such as those relating to the compliance with technical equipment, accident- preventing regulations, etc. Any calibration change shall be made using the operational software. Once the inverter has been disconnected from the power grid, powered parts and electrical connections shall not be touched as some capacitors could be charged. Comply with all corresponding marks and symbols present on each device. During operation, make sure that a...