Anleitung Liebert, modell Air Cooled, Direct Drive Condensers 308 415

Hersteller: Liebert
Dateigröße: 2.77 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


See Figures 3, 4 and 5 for anchor dimensions. 17 Inspection and Installation 3.6 Electrical Supply Preparation Line voltage electrical service is required for all models. Refer to equipment nameplate regarding wire size and circuit protection requirements. Electrical service must conform to national and local electrical codes. Refer to Figures 19, 20 and 21 for electrical service entrances into unit. Refer to electrical schematic when making connections. Each unit is shipped from the factory with all internal unit wiring completed. ! WARNING Risk of electric shock. Can cause injury or death. Disconnect all local and remote electrical power supplies before working within the electrical enclosure. The line side of the disconnect remains energized when the disconnect is Off. Use a voltmeter to verify that the electrical power is Off before performing any electrical and/or mechanical service and/or maintenance operations. ! WARNING Risk of high speed moving parts. Can cause injury or death. The fan(s) blades can start to rotate unexpectedly when the power is On. Disconnect all local and remote electrical power supplies before working within the fan compartment. Use a voltmeter to verify that the electrical power is Off before performing any electrical and/or mechanical service and/or maintenance operations. Each unit is shipped from the factory with all internal unit wiring completed. Refer to the electrical schematic supplied with the condenser when making line voltage supply, low voltage indoor unit interlock and any low voltage alarm connections. All wiring must be done in accordance with all applicable local, state and national electrical codes. 3.6.1 Line Voltage Wiring ! WARNING Risk electrical fire and short circuit. Can cause property damage, injury or death. Select and install the electrical supply wire and overcurrent protection device(s) according to the specifications on the unit nameplate(s), per the instructions in this manual and according to the applicable national, state and local code requirements. Use copper conductors only. Make sure all electrical connections are tight. Unit-specific wiring diagrams are provided on each unit. Condenser-rated voltage should be verified with available power supply before installation. Refer to the unit’s electrical schematic and serial tag for specific electrical requirements. Line voltage electrical service is required for all condensers at the location of the condenser. The power supply does not necessarily have to be the same voltage supply as required by the indoor unit connected to the condenser. See the unit’s serial tag for specific condenser electrical requirements. A unit disconnect is standard on VFD and Quiet-Line Condensers and is optional on Fan Speed Control and standard Lee-Temp condensers. However, a site disconnect may be required per local code to isolate the unit for maintenance. Route the supply power to the site disconnect switch and then to the unit. Route the conduit through the hole provided in the cabinet. Connect earth ground to lug provided near terminal board. NOTE Lee-Temp and Quiet-Line Condensers require a separate line voltage electrical supply for the heated receivers. See Table 8 for power requirements. 18 Inspection and Installation Table 5 60Hz condenser data Model # 83, 104 165, 205 251, 308 415, 510 616 830, 1010 # of Fans 1 2 3 4 6 8 InputVoltage ph FLA WSA OPD FLA WSA OPD FLA WSA OPD FLA WSA OPD FLA WSA OPD FLA WSA OPD Fan Speed Controlled 208/230 1 4.8 6.0 15 — — — — — — — — — — — — — — — 460 2.5 3.1 15 — — — — — — — — — — — — — — — 575 1.9 2.4 15 — — — — — — — — — — — — — — — 208/230 3 — — — 8.3 9.5 15 11.8 13.0 15 15.3 16.5 20 23.6 24.8 25 30.6 31.8 35 460 — — — 4.2 4.8 15 5.9 6.5 15 7.6 8.2 15 11.8 12.4 15 15.2 15.8 20 575 — — — 3.3 3.8 15 4.7 5.2 15 6.1 6.6 15 9.4 9.9 15 12.2 12.7 15 VFD Controlled 208/230 3 3.7 4.6 15 7.2 8.1 15 10.7 11.6 15 14.2 15.1 20 N/A N/A N/A N/A N/A N/A 460 1.8 2.3 15 3.5 4.0 15 5.2 5.7 15 6.9 7.4 15 N/A N/A N/A N/A N/A N/A Lee-Temp Controlled/Fan-Cycling 208/230 3 3.5 4.4 15 7.0 7.9 15 10.5 11.4 15 14.0 14.9 15 21.0 21.9 25 28.0 28.9 30 460 1.7 2.1 15 3.4 3.8 15 5.1 5.5 15 6.8 7.2 15 10.2 10.6 15 13.6 14.0 15 575 1.4 1.8 15 2.8 3.2 15 4.2 4.6 15 5.6 6.0 15 8.4 8.8 15 11.2 11.6 15 FLA = Full Load Amps; WSA = Wire Size Amps; OPD = Maximum Overcurrent Protection Device Table 6 60Hz condenser data, Quiet-Line (Lee-Temp controlled/fan-cycling) Model # ph 63 119, 127, 143 214 286 409 572 # of Fans 1 2 3 4 6 8 InputVoltage ph FLA WSA OPD FLA WSA OPD FLA WSA OPD FLA WSA OPD FLA WSA OPD FLA WSA OPD 208/230 1.8 2.3 15 3.6 4.1 15 5.4 5.9 15 7.2 7.7 15 10.8 11.3 15 14.4 14.9 15 460 3 0.9 1.1 15 1.8 2.0 15 2.7 2.9 15 3.6 3.8 15 5.4 5.6 15 7.2 7.4 15 575 0.7 0.9 15 1.4 1.6 15 2.1 2.3 15 2.8 3.0 15 4.2 4.4 15 5.6 5.8 15 FLA = Full Load Amps; WSA = Wire Size Amps; OPD = Maximum Overcurrent Protection Device Table 7 50Hz condenser full load amp values Condenser Control Type Fan SpeedControlled VFD Control...

Dieses Handbuch ist für folgende Modelle:
Trockner - Air Cooled, Direct Drive Condensers 1010 (2.77 mb)
Trockner - Air Cooled, Direct Drive Condensers 104 165 (2.77 mb)
Trockner - Air Cooled, Direct Drive Condensers 205 251 (2.77 mb)
Trockner - Air Cooled, Direct Drive Condensers 510 616 830 (2.77 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien