Login:
Stimmen - 2, Durchschnittliche Bewertung: 5 ( )

Anleitung Maytag, modell Epic z W10112943A

Hersteller: Maytag
Dateigröße: 1.81 mb
Dateiname: 7e1717e4-9dee-4ef7-976c-2a657ef66d46.pdf
Unterrichtssprache:enesfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


¦ Do not use an exhaust hood with a magnetic latch. Improper venting can cause moisture and lint to collect indoors, which may result in: Moisture damage to woodwork, furniture, paint, wallpaper, carpets, etc. Housecleaning problems and health problems. 11 Plan Vent System Choose your exhaust installation type Recommended exhaust installations Typical installations vent the dryer from the rear of the dryer. Other installations are possible. B C D A E F G H A. Dryer E. Clamps B. Elbow F. Rigid metal or flexible metal vent C. Wall G. Vent length necessary to connect elbows D. Exhaust hood H. Exhaust outlet Optional exhaust installations WARNING Fire Hazard Cover unused exhaust holes with one of the following kits: 279818 (white) 279820 (black) 280102 (pacific blue) Contact your local dealer. Failure to follow these instructions fire, electrical shock, or This dryer can be converted to exhaust out the right side, left side, or through the bottom. Contact your local dealer to have the dryer converted. AB C A. Standard rear offset exhaust installation B. Left or right side exhaust installation C. Bottom exhaust installation (not an option with pedestal installations) Alternate installations for close clearances Venting systems come in many varieties. Select the type best for your installation. Two close- clearance installations are shown. Refer to the manufacturer’s instructions. A B A. Over- the- top installation (also available with one offset elbow) B. Periscope installation NOTE: The following kits for close clearance alternate installations are available for purchase. Please see the “Assistance or Service” section to order. ¦ Over-the-Top Installation: Part Number 4396028 ¦ Periscope Installation (For use with dryer vent to wall vent mismatch) : Part Number 4396037 - 0" ( 0 cm) to 18" (45.72 cm) mismatch Part Number 4396011 - 18" (45.72 cm) to 29" (73.66 cm) mismatch Part Number 4396014 - 29" (73.66 cm) to 50" (127 cm) mismatch 12 Special provisions for mobile home installations The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside. Determine vent path ¦ Select the route that will provide the straightest and most direct path outdoors. ¦ Plan the installation to use the fewest number of elbows and turns. ¦ When using elbows or making turns, allow as much room as possible. ¦ Bend vent gradually to avoid kinking. ¦ Use the fewest 90° turns possible. Determine vent length and elbows needed for best drying performance ¦ Use the following Vent system chart to determine type of vent material and hood combinations acceptable to use. NOTE: Do not use vent runs longer than those specified in the Vent system chart. Exhaust systems longer than those specified will: ¦ Shorten the life of the dryer. ¦ Reduce performance, resulting in longer drying times and increased energy usage. The Vent system chart provides venting requirements that will help to achieve the best drying performance. Vent system chart NOTE: Side and bottom exhaust installations have a 90. turn inside the dryer. To determine maximum exhaust length, add one 90 . turn to the chart. Number of 90 . turns or elbows Type of vent Box or louvered hoods Angled hoods 0 Rigid metal Flexible metal 64 ft (20 m) 36 ft (11 m) 58 ft (17.7 m) 28 ft (8.5 m) 1 Rigid metal Flexible metal 54 ft (16.5 m) 31 ft ( 9.4 m) 48 ft (14.6 m) 23 ft (7 m) 2 Rigid metal Flexible metal 44 ft (13.4 m) 27 ft ( 8.2 m) 38 ft (11.6 m) 19 ft (5.8 m) 3 Rigid metal Flexible metal 35 ft (10.7 m) 25 ft ( 7.6 m) 29 ft (8.8 m) 17 ft (5.2 m) 4 Rigid metal Flexible metal 27 ft ( 8.2 m) 23 ft (7 m) 21 ft (6.4 m) 15 ft (4.6 m) Install Vent System 1. Install exhaust hood. Use caulking compound to seal exterior wall opening around exhaust hood. 2. Connect vent to exhaust hood. Vent must fit inside exhaust hood. Secure vent to exhaust hood with 4" ( 10.2 cm) clamp. 3. Run vent to dryer location. Use the straightest path possible. See “ Determine vent path” in “ Plan Vent System.” Avoid 90 . turns. Use clamps to seal all joints. Do not use duct tape, screws or other fastening devices that extend into the interior of the vent to secure vent. Install Leveling Legs WARNING Excessive Weight Hazard Use two or more people to move and install dryer. Failure to do so can result in back or other injury. 1. To protect the floor, use a large flat piece of cardboard from the dryer carton. Place cardboard under the entire back edge of the dryer. 13 2. Firmly grasp the body of the dryer. Gently lay the dryer on the cardboard. See illustration. 3. Examine the leveling legs. Find the diamond marking. 4. Screw the legs into the leg holes by hand. Use a wrench to finish turning the legs until the diamond marking is no longer visible. 5. Place a carton corner post from dryer packaging under each of the 2 dryer back corners. Stand the dryer up. Slide the dryer on the corner posts until it is close t...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien