Login:
Stimmen - 3, Durchschnittliche Bewertung: 4 ( )

Anleitung Maytag, modell 53-3442

Hersteller: Maytag
Dateigröße: 337.61 kb
Dateiname: b968f13a-6e3c-473d-b0f1-18873cb30121.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Allliteratureshouldbe removedfrominsidedryerand savedfor future reference. [" NOTE:DO NOTRAISEOR LOWERTHEDRYERBY THE BACKGUARD. 1.Toremovethecorrugatedcratebase,placeyour _footonthebasecloseto a levelingfoot.Pushing downfirmlywithyourfoot,tiltthe dryerawayfrom you. 2. Repeatprocesswithall levelingfeet (4). Remove _---._. -_ , excessbasebyhand. CORRUGATED CRATE PLACE FOOT P/N 53-3442 BASE FOR LEVERAGE 1 NSTALLATION REC!UREMENTS PLEASE READ All Installation Instructions and Requirements Before Installing Power Cord. IT IS RECOMMENDED THAT A QUALIRED ELECTRk ClANOR SERVICETECHNICIANINSTALLYOUR DRYER. LOCATION This clothes dryer is designed so that it can be installed in most locations in the home. The dryer may even be installed in an unheated indoor location, such as a utility room or building. However, with models having automatic dry cycles, the TIME DRY SETTING SHOULD BE USED WHEN THE ROOM TEMPERATURE DROPS BELOW 50 DEGREES FAHRENHEIT OR (10 DEGREES C.), AS THE AUTOMATIC CYCLE MAY NOT SHUT OFF. DO NOT INSTALL THE DRYER ON A CARPETED FLOOR. DO NOT INSTALL OR STORE THE DRYER WHERE IT MAY BE EXPOSED TO THE WEATHER OR DRIPPING WATER. IF IT IS EVER EXPOSED TO WATER, HAVE A QUALIFIED TECHNICIAN CHECK IT BEFORE USING. THE INSTALLATION MUST BE MADE WITH ADEQUATE CLEARANCE TO PERMIT SERVICING. In ordinary installations enough air will be available for proper operation of the dryer. However, if the dryer is installed in a mobile home, acloset or a tightly sealed room, provisions should be made for at least 18 square inches of ventilation area. Air openings measuring a minimum 3 in.by 3 in. should Dryers installed in manufactured (mobile) homes must be connected with 4 conductor type SRD or SRDT cord to a 3 pole, 4 wire grounding type receptacle; by metal-clad cable; or suitable conductors enclosed in flexible metal conduit. If using metal-clad cable or flexible conduit, leave at least 3 feet free to permit moving the dryer. Where permitted by local codes, a flexible power cord (pigtail) may be connected to the dryer. A receptacle should be installed in a separate circuit connected to the main service entrance panel for this type ofinstallation. See Figure #3. Useonlya 3 or4 wire power cord kit,includingstrain relief, listedby U.L. for use withdryers.The power cord must have a rating of 30 amperes, 120/240 voltsAC minimum and be terminatedinclosed loop or open spade lugs with upturned ends. The attachment plugof the power cordand the receptacle towhich it willbe connected musthave a minimumcur rent ratingof 30 amps and have matching configurations. Typical30 ampereconfigurations are illustratedinfigure#3. GROUNDING INSTRUCTIONS This appliance MUST BE CONNECTED TO A GROUNDED METAL PERMANENT WIRING SYSTEM; or anequipmentgroundingconductormust be runwith thecircuitconductors and connected to the equipment-grounding terminal orlead on the appliance. CONNECTINGTHEDRYER II _ABOVE BRASS STRAP must be exhausted outdoors. ELECTRICAL REQUIREMENTS This phase of the installation should be done by a qualified service technician or electrician in accordance with the A separate circuit must be provided from the main service entrance panel (fuse box) to the dryer.The circuit must be a 3 or 4 wire, 120/240 volt, 60 Hz, single phase, AC circuit. Each of the 120 volt line wires (linet and 2) of thiscircuitmust be ++++++++++°++++ protected by 30 ampere time delay fuses or circuit breakers. Do not fuse the neutral line or the ground line (if provided). All wires (including neutral and ground if provided) of the dryer circuit must be No. 10 gauge copper wire for up to 40 ft. lengths and No. 8 gauge copper wire for up to 60 ft. Lengths.NEVER USE A TWO WIRE CABLE WITH AN UNINSULATED GROUND WIRE TO CONNECT THE DRYER. The National Electric Code requires that a means to discon nect all ungrounded conductors (line 1 and line 2) to the dryerbe provided for service. Ifa power cord and receptacle are provided this requirement is met. If other means are used a suitable switch or circuit breaker must be installed within sight of the dryer. I FIG.#1-3WIRE HOTWIREROUTED Ordinarily, Iouvered doors will satisfy the ventilation require-LINE ments. Dryers installed in a bedroom, bathroom, or closet (BLACI< ++o+++0++o,,+++,+ I ++++0I I "-/.CRASSSTRAP/--STRAIN | -._..11 CLAMP I ml "'"// [/,_-_._/'/(_._:'-_POWER I NEUTRAl r{l_ll__#//_CORD _-_-"-{/// (WRITE _ _.-;___,_ LINE2 (RED) I I IWJ 'NEUTRALWIRE HOTWIREROUTED _--_J ROUTEDBELOW BELOWBRASS STRAP BRASS STRAP I THE NATIONAL ELECTRICAL CODE ANDALL LOCAL CODES AND ORDINANCES MUST BE OBSERVED WHEN CONNECTING THIS DRYER. 1. Togain access to the terminal block, remove the supply cord cover plate attached to the rear of the dryer. 2. Install a suitable strain relief clamp or connector in the strain relief hole located adjacent to the terminal block. 2 3. Route the power cord (pigtail) or cable conductors through the strain relief clamp. FIG. #2 -4 WIRE TERMINALBLOCK ,_ CAUTION -Theconductorsshould not extend into...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien