Anleitung Alliance Laundry Systems, modell 907003062

Hersteller: Alliance Laundry Systems
Dateigröße: 882.87 kb
Dateiname: 70420801en.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


• Never start the tumble dryer with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumble dryer is properly grounded. W002R1 To reduce the risk of fire and electric shock, check with a qualified servicemanfor proper grounding procedures. Improper connection of the equipment grounding conductor may result in a riskof electric shock. W068 To reduce the risk of fire and electric shock, if electrical supply is coming from a three phase service, DO NOT connect a “High Leg” or “Stinger Leg” to a singlephase machine. On a three phase machine, if there is a “High Leg” or “Stinger Leg” it should be connected to L3. W069 NOTE: To ensure protection against shock, this tumble dryer MUST be electrically grounded in accordance with the local codes or, in the absence of local codes, with the latest edition of the National Electrical Code ANSI/NFPA No. 70. In Canada the electrical connections are to be made in accordance with CSA C22.1 latest edition Canadian Electrical Code, Part I and/or local codes. Electrical work should be done by a qualified electrician. IMPORTANT: Electrical connections must be made by a qualified electrician using data on serial plate, installation manuals and wiring diagram provided with machine and according to local codes. Install a circuit breaker as close to the tumble dryer as possible. If more than one tumble dryer is being installed, a circuit breaker must be provided for each. NOTE: Connect machine to an individual branch circuit not shared with lighting or other equipment. NOTE: 3 Phase Machines Only - Do not use fuses to avoid the possibility of “single phasing” and causing premature failure of the motors. WARNING In case of servicing (or putting the tumble dryer out of order), disconnect the tumble dryer from the main supply by switching off the circuit breaker. W796 Grounding Instructions This tumble dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This tumble dryer must be connected to a grounded metal, permanent wiring system; or an equipment grounding conductor must be run with the circuit conductors and connected to the appropriate ground location. Metal conduit and/or BX cable is not considered ground. Connecting the Neutral from the electrical service box to the tumble dryer ground screw does not constitute a ground. A dedicated ground conduit (wire) must be connected between the electrical service box ground bar and the tumble dryer ground screw. WARNING All electrical connections should be made by a qualified electrician. To reduce the risk of electrical shock, de- energize the electrical circuit being connected to the tumble dryer before making any electrical connections. Never attempt to connect a live circuit. W070R1 CAUTION Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. W071 70420801 (EN) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Electrical Requirements 32 70420801 (EN) Service/Ground Location Model Ground and Terminal Block Locations Gas and Steam Electric Figure 9 Ground TMB2269N Electrical Service Terminal Block Junction Box TMB2337N Ground Electrical Service Terminal Block Contactor Box TMB2337N To Connect Electrical Service to the Tumble Dryer NOTE: The wiring diagram is located in the junction or contactor box. 1. Install a circuit breaker as close to the tumble dryer as possible. If more than one tumble dryer is being installed, a circuit breaker should be provided for each. This will make it possible to disconnect each tumble dryer for maintenance purposes. 2. Connect conduit-encased leads to the circuit breaker. Connect wire leads to the appropriate labeled terminal on the terminal block. The ground wire must be connected to the ground connection as shown in Figure 9. 3. Check the electrical service phase sequence (three phase only). If one of the power leads is a “high leg,” connect it to lead L3 in the tumble dryer. The cylinder must rotate clockwise and the fan must rotate counterclockwise (as viewed from the front of the tumble dryer – with selector switch in non-reverse position). If not, interchange leads L1 and L2 in the tumble dryer connection box. Jumper Configuration Instructions Changing the transformer configuration jumper is required, PRIOR TO SUPPLYING POWER TO THE MACHINE, if any of the following apply: IMPORTANT: Failure to install the proper configuration jumper may result in damage to sensitive electronic controls and may void warranty. • Location Voltage 200 – 208 Volt service and are connecting a model rated for 240 Volt operation. Replace the 240 Volt jumper with the 208 Volt jumper per the conversion label, located on the...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien