SUPPLY SOURCE: Use only clean regulated compressed air as a power source for this tool. NEVER USE OXYGEN, COMBUSTIBLE GASES, OR BOTTLED GASES, AS A POWER SOURCE FOR THIS TOOL AS TOOL MAY EXPLODE. REGULATOR: A pressure regulator with an operating pressure of 0 - 125 p.s.i. (0 - 8.79 kg/cm2) is required to control the operatiing pressure for safe operation of this tool. Do not connect this tool to air pressure which can potentially exceed 200 p.s.i. (14 kg/cm2) as tool may fracture or burst, possi
The operator must not hold the trigger pulled on contact trip tools except during fastening operation, as serious injury could result if the trip accidentally contacted someone or something, causing the tool to cycle. Keep hands and body away from the discharge area of the tool. A contact trip tool may bounce from the recoil of driving a fastener and an unwanted second fastener may be driven, possibly causing injury. 3. SEQUENTIAL TRIP OPERATION: The SEQUENTIAL TRIP MODEL contains a contact trip
Contact your Bostitch representative or distributor with any questions concerning the tool and its use. Bostitch, Inc., East Greenwich, Rhode Island 02818. INDEX Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Tool Specifications: Air Consumption & Operating Pressure . . . . . . . . . . . . . . . 4 Air Supply: Fittings, Hoses, Filters, Regulators . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Lubrication and Cold Weathe
. . . . . . . . . .Replace quick disconnect fittings Worn piston O-ring . . . . . . . . . . . . . . . . . . . . . .Replace O-ring, check driver Tool dry, lacks lubrication . . . . . . . . . . . . . . . . .Use BOSTITCH Air Tool Lubricant Damaged pusher spring . . . . . . . . . . . . . . . . . .Replace spring Low air pressure . . . . . . . . . . . . . . . . . . . . . . . .Check air supply system to tool Loose magazine nose screws . . . . . . . . . . . . . .Tighten all screws Fasteners too short fo
CAUTION: Do not store tools in a cold weather environment to prevent frost or ice formation on the tools operating valves and mechanisms that could cause tool failure. NOTE:Some commercial air line drying liquids are harmful to “O”-rings and seals – do not use these low temperature air dryers without checking compatibility. 5 LOADING THE N400S EYE PROTECTION which conforms to ANSI specifications and provides protection against flying particles both from the FRONT and SIDE should ALWAYS be worn b
Do not use the tool if the arm is not working correctly as accidental driving of a fastener may result. Do not interfere with the proper operation of the contact arm mechanism. Do not drive fasteners on top of other fasteners or with the tool at an overly steep angle as this may cause deflection of fasteners which could cause injury. Do not drive fasteners close to the edge of the work piece as the wood may split, allowing the fastener to be deflected possibly causing injury. This nailer produce
Air Consumption: The EHF1838K requires 1.94 cubic feet per minute or C.F.M. (54.93 liters per minute or LT/MIN) of free air at 80PSI (5.6 kg/cm2) to operate at a rate of 60 fasteners per minute. The LHF2025K requires 1.90 cubic feet per minute or C.F.M. (53.8 liters per minute or LT/MIN) of free air at 80PSI (5.6 kg/cm2) to operate at a rate of 60 fasteners per minute. To determine the appropriately sized air compressor, take the actual rate at which the tool will be run and compare the required
KEEP THESE INSTRUCTIONS WITH THE TOOL FOR FUTURE REFERENCE. IF YOU HAVE ANY QUESTIONS, CONTACT YOUR BOSTITCH REPRESENTATIVE OR DISTRIBUTOR. ANTES DE OPERAR ESTA HERRAMIENTA, TODOS LOS OPERADORES DEBERAN ESTUDIAR ESTE MANUAL PARA PODER COMPRENDER Y SEGUIR LAS ADVERTENCIAS SOBRE SEGURIDAD Y LAS INSTRUCCIONES. MANTENGA ESTAS INSTRUCCIONES CON LA HERRAMIENTA PARA FUTURA REFERENCIA, SI TIENE ALGUNA DUDA, COMUNIQUESE CON SU REPRESENTANTE DE BOSTITCH O CON SU DISTRIBUIDOR. LIRE ATTENTIVEMENT LE PRESENT
The air volume supplied to the tool may be inadequate because of undersize fittings and hoses, or from the effects of dirt and water in the system. Restricted air flow will prevent the tool from receiving an adequate volume of air, even though the pressure reading is high. The results will be slow operation, misfeeds or reduced driving power. Before evaluating tool problems for these symptoms, trace the air supply from the tool to the supply source for restrictive connectors, swivel fittings, lo
Always disconnect air supply: 1.) Before making adjustments; 2.) When servicing the tool; 3.) When clearing a jam; 4.) When tool is not in use; 5.) When moving to a different work area, as accidental actuation may occur, possibly causing injury. LOADING TOOL When loading tool: 1.) Never place a hand or any part of body in fastener discharge area of tool; 2.) Never point tool at anyone; 3.) Do not pull the trigger or depress the trip as accidental actuation may occur, possibly causing injury. OPE