Anleitung Porter-Cable, modell 8604

Hersteller: Porter-Cable
Dateigröße: 294.54 kb
Dateiname: 072073ef-4559-4968-ac9d-55dbda1fcbb2.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


• Do not connect this tool to a system with maximum potential pressure greater than 200 PSI, (13 BAR). • Only connect tool to air supply with a coupling that will release all pressure from the tool when disconnected. • Disconnect tool from air supply and/or remove battery before performing maintenance, clearing a jammed fastener, leaving work area, moving tool to another location, handing the tool to another person, or making adjustments. PREPARING THE TOOL 1. After reading and understanding this entire manual, install a fully charged battery pack (see BATTERY OPERATION) or connect tool to external air supply (see Fig. 14 and 14A). WARNING: Keep tool pointed away from yourself and others at all times. • Always connect tool to battery pack or air supply before loading fasteners. Do not load fasteners with trigger or safety depressed. (see Figures 14 and 14A). The male connector must be rotated to the 8 o’clock or closed position (A) Fig. 14A for Internal air operation. If External air is to be used, slide switch to the EXT AIR position, then rotate the male connector to the 12 o’clock position (B) Fig. 14A for quick coupling connection. After connection, the male connector can then be rotated to the 3 o’clock position (C) Fig. 14A for operator convenience. • Only use approved Porter-Cable fasteners. • Operator and all bystanders should always wear Z87.1 approved safety glasses with side shields, and hearing protection when preparing or operating the tool. • Never use a tool that leaks air or needs repair. 2. Depress latch (A) Fig. 15 and slide magazine cover open. 3. Insert a strip of approved fasteners, (B) Fig. 16. Orient fasteners with points down, and in contact with the bottom of the magazine. 4. Push magazine cover closed, see Fig. 17. 5. Adjust directional exhaust deflector (A) Fig. 18, so that the exhaust air blast will be directed away from the operator. The exhaust deflector provides 8 detented positions for directing the exhaust blast away from the operator. Grasp the deflector and rotate it to the desired position for the current application. 9 901891 - 08-31-01.qxd 2/13/02 11:52 AM Page 10 Fig. 16 Fig. 17 < > Fig. 14A Fig. 15 Fig. 18 A Fig. 14 A B A B C < OPERATION USING THE TOOL Complete all steps of PREPARING THE TOOL before using the tool. To fasten, move switch (A) Fig. 19 to desired position, grip tool firmly, position nose of tool onto work surface, push forward on tool to depress safety, and squeeze trigger to fire a fastener while allowing tool to recoil. WARNING: Remove finger from trigger when not driving fasteners. Never carry tool with finger on trigger: tool may fire a fastener if safety is bumped. WARNING: Keep tool pointed in a safe direction at all times. WARNING: Never attempt to drive a fastener into material that is too hard, or at too steep an angle, or near the edge of the workpiece. The fastener can ricochet causing personal injury. 10 901891 - 08-31-01.qxd 2/13/02 11:52 AM Page 11 WARNING: Disconnect tool from air supply and/or remove battery before performing maintenance, clearing a jammed fastener, leaving work area, moving tool to another location, handing the tool to another person, making adjustments. WARNING: Clean and inspect tool daily. Carefully check for proper operation of trigger and safety mechanism. Do Not use the tool unless both the trigger and the safety mechanism are functional, or if the tool is leaking air or needs any other repair. Built in LED self diagnostics (B) Fig. 19 inform the user to the tool’s operation status. Tool operation safety status is outlined in the following chart. Fig. 19A A Fig. 19 A • HIGH • NORMAL • OFF • EXT AIR B • • • • LED STATUS Solid Green LED Flashing Green LED Fast Flashing Red LED Slow Flashing Red LED Solid Red LED DIAGNOSTIC CONITION Tool up to pressure and safe to operate. Tool pressure building. Quick connect valve open. Auto shut down activated. Low voltage. ACTION Use tool in normal manner. Wait for Solid Green. Rotate quick connect valve to 8 o’clock closed position see (A) Fig. 14A. Turn tool off and on to reset. Recharge battery.• The depth to which a fastener is driven is controlled by the depth adjustment knob (A) Fig. 19A. The depth of drive is factory adjusted to a nominal setting. Test fire a fastener and check depth. If a change is desired, rotate the adjustment knob (A) Fig. 19A: the adjustment knob has detents every 1/4 turn. Rotate the knob clockwise (see Fig. 19A), to increase the depth of drive, rotate the knob counterclockwise to decrease the depth of drive. Test fire another fastener and check depth. Repeat as necessary to achieve desired results. The amount of air pressure required will vary depending on the size of the fastener and the material being fastened. Experiment with the air pressure setting to determine the lowest setting that will consistently perform the job at hand. Air pressure in excess of that required can cause premature wear and/or damage to the tool. 11 901891 - 08-31-01.qxd 2/1...

Dieses Handbuch ist für folgende Modelle:
Nailers - BN200V12 (294.54 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien